NCCER MODULE 6 DEVICE BOXES PULL
JUNCTION BOXES CERTIFICATION
EVALUATION TEST 2026 PRACTICE
SOLUTION QUESTIONS AND ANSWERS
โ—โ— Square boxes are typically available in 2 sizes
Answer: 4" and 4 11/16"
โ—โ— Both sizes are available in 3 depths
Answer: 1 1/4", 1 1/2" and 2 1/8"
โ—โ— If a deeper box is needed
Answer: A square extension ring is used
โ—โ— Handy box
Answer: A single gang box, also known as a utility box
โ—โ— Masonry box (concrete box)
Answer: Special type of box is typically used in flat-slab construction
jobs
โ—โ— Rain tight
pf3
pf4

Partial preview of the text

Download NCCER MODULE 6 DEVICE BOXES PULL JUNCTION BOXES CERTIFICATION EVALUATION TEST 2026 PRACTIC and more Exams Electrical Engineering in PDF only on Docsity!

NCCER MODULE 6 DEVICE BOXES PULL

JUNCTION BOXES CERTIFICATION

EVALUATION TEST 2026 PRACTICE

SOLUTION QUESTIONS AND ANSWERS

โ—โ— Square boxes are typically available in 2 sizes Answer: 4" and 4 11/16" โ—โ— Both sizes are available in 3 depths Answer: 1 1/4", 1 1/2" and 2 1/8" โ—โ— If a deeper box is needed Answer: A square extension ring is used โ—โ— Handy box Answer: A single gang box, also known as a utility box โ—โ— Masonry box (concrete box) Answer: Special type of box is typically used in flat-slab construction jobs โ—โ— Rain tight

Answer: Something that's built out protected to keep out water during heavy rain under specific conditions โ—โ— Water tight Answer: Something that's built so that water will not get inside of it under specific conditions โ—โ— Wet location Answer: Subject to saturation, locations exposed to weather or water โ—โ— Damp location Answer: Subject to some degree of moisture, open porches with a roof โ—โ— NEC section 210. Answer: States the minimum requirements for the location of receptacles in dwelling units โ—โ— At least 1 receptacle is required: Answer: In each laundry area, within 3' of bathroom basins & on the outside of of the building at the front and back (GCFI protected) โ—โ— Knock out punch kit

Answer: Use 6" in equations โ—โ— Straight runs in conduit Answer: Use 8" in equations โ—โ—