NEIEP 500 Final Exam Questions with Complete Solution
1. Ground
(515
pg.
26)
What does the symbol shown below represent?
2.
3 (555 pg. 26)
How many turns of safety rope must remain on the
safety drum after a rated load and rated speed test of
a winding drum
operated safety?
3. rail jack bolts (555 pg. 16)
Proper
adjustment
of
which
of
the
following
can
reduce
the
ettects
of
building
compression
on
an
elevator
installation?
4.
Liquidtight Flexible
Metal Conduit (505
pg. 6)
What type of flex would be used to pipe a switch in a wet
location?
5. door clutch (530 pg.
30)
Which of the following components is used to engage
and
couple the car door to the hoistway door during
opening and
closing?
6.
100
feet
(510
pg.
10)
On
high
rise
of
raceways,
the
wires
must
be
supported
at
least
how many feet?
7.
#14
(505
pg.
36)
What
is
the
minimum
size
wire
allowed
be
code
for
wiring
100
VAC
lighting
circuits
to
elevator
cars?
pf3
pf4
pf5

Partial preview of the text

Download NEIEP 500 Final Exam Questions with Complete Solution and more Exams Electrical and Electronics Engineering in PDF only on Docsity!

1 / NEIEP 500 Final Exam Questions with Complete Solution

  1. Ground (515 pg. 26) What does the symbol shown below represent?
  2. 3 (555 pg. 26) How many turns of safety rope must remain on the safety drum after a rated load and rated speed test of a winding drum operated safety?
  3. rail jack bolts (555 pg. 16) Proper adjustment of which of the following can reduce the ettects of building compression on an elevator installation?
  4. Liquidtight Flexible Metal Conduit ( pg. 6) What type of flex would be used to pipe a switch in a wet location?
  5. door clutch (530 pg. 30) Which of the following components is used to engage and couple the car door to the hoistway door during opening and closing?
  6. 100 feet (510 pg. 10) On high rise of raceways, the wires must be supported at least how many feet?
  7. #14 (505 pg. 36) What is the minimum size wire allowed be code for wiring 100 VAC lighting circuits to elevator cars?

2 / NEIEP 500 Final Exam Questions with Complete Solution

  1. raceway (505 pg. 1) What is the metal enclosure that furnishes protection for elec- trical wire called?
  2. 42 inches What is the minimum height of a barricade placed around as open hoistway?

4 / NEIEP 500 Final Exam Questions with Complete Solution waiters? What terminals in the hoistway junctions box could most likely be hot even with the main line disconnect open?

  1. 7 feet (510 pg. 21) What is the minimum overhead clearance for raceways mount- ed in the machine room overhead?
  2. 45 inches (515 pg. 8) What is the minimum loop size for 1 1/2 inch traveling cable?

5 /

  1. All splices must be accessible after installation is complete Which of the following is correct about splicing wires?
  2. Isolated What type of cab platform frame is required when a platform load weighing system is being included?
  3. The loop circuit is open (520 pg. 11)
  4. Store the doors vertically on the long edge (525 pg. 8) If there is voltage at the generator armature but not at the motor armature, what is most likely wrong? You need to store a shipment of passenger hoistway doors. Which of the following statement is true?
  5. 42 inches (525 pg. 21)f You are installing push button boxes in a high rise building. What is the maximum height that they can be located from the floor level to the center of the fixture?
  6. Prevents the door from being dislodged off the track by ex- ternal force (525 pg. 24) What is the purpose of the eccentric used on hoistway door hangers?
  7. 1 1/2 inch (525 pg.12) What is the maximum clearance allowed between the hoistway sill and the platform sill for passenger elevators?
  8. 18 inches (525 pg 16) You are adjusting the passenger doors for a traction drive with generator field control. What is the maximum distance the car can be from floor level before the doors unlock?
  9. High voltage wye connection (510 pg. 44 &
  1. Interchange any 2 leads (

7 / The building contracts (510 pg. 8)

  1. HSC is closed to increase the voltage across the armature (530 pg. 13)
  2. During the closing sequence the A1 terminal on the arma- ture is positive. (530 pg. 13)
  3. It will increase torque and de- crease speed. ( pg. 16) As concrete in a reinforced concrete building cures, what hap- pens? When closing in high speed which of the following statements is correct? Refer to figure 3. Which of the following statements is correct? What will the ettect be of increasing the shunt field voltage of a DC door motor?
  4. Rail (505 pg. 28) With a multi-traveling cable installation, what will cable#1 be located closet to?