A concise overview of key provisions and standards from the national building code of the philippines (pd1096). It covers topics such as parking ratios for different building types (colleges, hospitals, hotels, offices), standard sizes for parking slots, minimum clearances and dimensions for various building elements (mezzanines, stairs, doors), open space requirements, and fire safety regulations. It also includes information on construction types, exit requirements, and ventilation standards, offering a quick reference for architects, engineers, and construction professionals. Useful for students and professionals in architecture, engineering, and construction management.
Typology: Exams
1 / 7
This page cannot be seen from the preview
Don't miss anything!




1:5 - ANSWER Colleges and university parking ratio. (classroom) 1:25 - ANSWER Hospital building parking ratio. (beds) 1:10 - ANSWER Hotel building parking ratio. bedrooms 2.40 x 5.00 - ANSWER Standard size of a perpendicular parking slot. 1:125 - ANSWER Office building parking ratio. gross flr area 1.50m - ANSWER Standard turn circle of a wheelchair. 2.40m - ANSWER Minimum height of a construction fence. 1.80m - ANSWER Minimum headroom clearance for a mezzanine.
50% of lot area - ANSWER Open space requirement for an interior lot. 10% of lot area - ANSWER Open space requirement for a corner lot or athrough lot.
750mm - ANSWER Minimum stair width for a residence. 1.20 - ANSWER Maximum width of an exit door leaf. PD 2 exits - ANSWER Minimum number of exit for floors above the first storeyhaving an occupant load of more than 10 pd
PD1096 - ANSWER NATIONAL BUILDING CODE OF THE PHILIPPINES 700mm - ANSWER Minimum clear width of an exit door way. PD 15 days - ANSWER Maximum number of days from payment of required feesfor issuance of building permit
Firezones - ANSWER Are areas within which only certain types of buildingsare permitted to be constructed based on their use or occupancy, type of
10 % - ANSWER Minimum total free area of window openings for roomswithout artificial ventilatio
3 exit - ANSWER Minimum number of exits for every storey or portionthereof having an occupant load of 500-
4 exit - ANSWER Minimum number of exits for every storey or portionthereof having an occupant load of 1000 or more
60m - ANSWER Maximum distance from any point in a building to anexterior exit door, a horizontal exit, exit passageway, or an enclosed stairway, for buildings equipped with a sprinkler system 45m - ANSWER Maximum distance from any point in a building to anexterior exit door, a horizontal exit, exit passageway, or an enclosed stairway, for buildings without a sprinkler system 900 - ANSWER Minimum door width PD 1.10m - ANSWER Minimum width of corridor or exit balcony 6.00m - ANSWER Maximum length of dead ends
1.20m - ANSWER Maximum width of exit door 6.00m - ANSWER Maximum length of dead ends 0.90m - ANSWER Minimum width of stairways serving an occupant load of50 or less
1.10m - ANSWER Minimum width of stairways serving an occupant load ofmore than 50
0.75m - ANSWER Minimum width of private stairways serving an occupantload less than 10
250mm - ANSWER Maximum run of stairway [,Chapter 12,] 200mm - ANSWER Maximum rise of stairway [,Chapter 12,] 3.60m - ANSWER Maximum vertical distance between landings 1 in 10 - ANSWER Maximum slope of exit courts