A concise overview of key provisions and standards from the national building code of the philippines (pd1096). It covers topics such as parking ratios for different building types (colleges, hospitals, hotels, offices), standard sizes for parking slots, minimum clearances and dimensions for various building elements (mezzanines, stairs, doors), open space requirements, and fire safety regulations. It also includes information on construction types, exit requirements, and ventilation standards, offering a quick reference for architects, engineers, and construction professionals. Useful for students and professionals in architecture, engineering, and construction management.

Typology: Exams

2024/2025

Available from 07/16/2025

Prof-Cornel
Prof-Cornel 🇺🇸

4.9K documents

1 / 7

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
PD1096 TEST WITH COMPLETE
SOLUTION
1:5 - ANSWER Colleges and university parking ratio. (classroom)
1:25 - ANSWER Hospital building parking ratio. (beds)
1:10 - ANSWER Hotel building parking ratio. bedrooms
2.40 x 5.00 - ANSWER Standard size of a perpendicular parking slot.
1:125 - ANSWER Office building parking ratio. gross flr area
1.50m - ANSWER Standard turn circle of a wheelchair.
2.40m - ANSWER Minimum height of a construction fence.
1.80m - ANSWER Minimum headroom clearance for a mezzanine.
pf3
pf4
pf5

Partial preview of the text

Download PD1096: Key Provisions of the National Building Code of the Philippines and more Exams Advanced Education in PDF only on Docsity!

PD1096 TES SOLT WITH COUTION MPLETE

1:5 - ANSWER Colleges and university parking ratio. (classroom) 1:25 - ANSWER Hospital building parking ratio. (beds) 1:10 - ANSWER Hotel building parking ratio. bedrooms 2.40 x 5.00 - ANSWER Standard size of a perpendicular parking slot. 1:125 - ANSWER Office building parking ratio. gross flr area 1.50m - ANSWER Standard turn circle of a wheelchair. 2.40m - ANSWER Minimum height of a construction fence. 1.80m - ANSWER Minimum headroom clearance for a mezzanine.

50% of lot area - ANSWER Open space requirement for an interior lot. 10% of lot area - ANSWER Open space requirement for a corner lot or athrough lot.

750mm - ANSWER Minimum stair width for a residence. 1.20 - ANSWER Maximum width of an exit door leaf. PD 2 exits - ANSWER Minimum number of exit for floors above the first storeyhaving an occupant load of more than 10 pd

PD1096 - ANSWER NATIONAL BUILDING CODE OF THE PHILIPPINES 700mm - ANSWER Minimum clear width of an exit door way. PD 15 days - ANSWER Maximum number of days from payment of required feesfor issuance of building permit

Firezones - ANSWER Are areas within which only certain types of buildingsare permitted to be constructed based on their use or occupancy, type of

10 % - ANSWER Minimum total free area of window openings for roomswithout artificial ventilatio

3 exit - ANSWER Minimum number of exits for every storey or portionthereof having an occupant load of 500-

4 exit - ANSWER Minimum number of exits for every storey or portionthereof having an occupant load of 1000 or more

60m - ANSWER Maximum distance from any point in a building to anexterior exit door, a horizontal exit, exit passageway, or an enclosed stairway, for buildings equipped with a sprinkler system 45m - ANSWER Maximum distance from any point in a building to anexterior exit door, a horizontal exit, exit passageway, or an enclosed stairway, for buildings without a sprinkler system 900 - ANSWER Minimum door width PD 1.10m - ANSWER Minimum width of corridor or exit balcony 6.00m - ANSWER Maximum length of dead ends

1.20m - ANSWER Maximum width of exit door 6.00m - ANSWER Maximum length of dead ends 0.90m - ANSWER Minimum width of stairways serving an occupant load of50 or less

1.10m - ANSWER Minimum width of stairways serving an occupant load ofmore than 50

0.75m - ANSWER Minimum width of private stairways serving an occupantload less than 10

250mm - ANSWER Maximum run of stairway [,Chapter 12,] 200mm - ANSWER Maximum rise of stairway [,Chapter 12,] 3.60m - ANSWER Maximum vertical distance between landings 1 in 10 - ANSWER Maximum slope of exit courts

  • Incombustible exterior wall Type 4 - ANSWER Type of Construction
  • Steel, iron, concrete, or masonry construction
  • Incombustible interiors (ceilings, walls) Type 5 - ANSWER Type of Construction
  • Four-hour fire resistive throughout- Structural elements of steel, iron, concrete or masonry 750 mm - ANSWER Eaves over required windows shall at least be______________ from the side and rear property lines.