Pumper EOC
Identify two correct statements about conducting a daily inspection of a fire
apparatus. - correct answer Confirm that the foam tank level is full
Operate the pump drive control
The rescue tool supply system equivalent of a junction box is called: - correct
answer A manifold
Vacuum test - correct answer Check for leaks in the priming device and pump
Pump capacity test - correct answer Checks the overall condition of the engine
Pressure control test - correct answer Verifies discharge pressure under varying
conditions
Gauge and Flowmeter - correct answer Compares meter readings with actual pitot
tube readings
Tank-to-pump rate - correct answer Measures whether the piping between an
apparatus's water tank and fire pump meet minimum flow standards
Identify three conditions where you should drive your fire apparatus in low gear -
correct answer Approaching an intersection
Climbing a hill
Traveling around a corner
Two true statements about inverters - correct answer Inverters are quiet as
compared to generators
Inverters output is usually limited to less than 1500 watts
pf3
pf4

Partial preview of the text

Download Pumper EOC-----------------------Pumper EOC and more Exams Advanced Education in PDF only on Docsity!

Pumper EOC

Identify two correct statements about conducting a daily inspection of a fire apparatus. - correct answer Confirm that the foam tank level is full Operate the pump drive control The rescue tool supply system equivalent of a junction box is called: - correct answer A manifold Vacuum test - correct answer Check for leaks in the priming device and pump Pump capacity test - correct answer Checks the overall condition of the engine Pressure control test - correct answer Verifies discharge pressure under varying conditions Gauge and Flowmeter - correct answer Compares meter readings with actual pitot tube readings Tank-to-pump rate - correct answer Measures whether the piping between an apparatus's water tank and fire pump meet minimum flow standards Identify three conditions where you should drive your fire apparatus in low gear - correct answer Approaching an intersection Climbing a hill Traveling around a corner Two true statements about inverters - correct answer Inverters are quiet as compared to generators Inverters output is usually limited to less than 1500 watts

The purchase acceptance test on a new fire apparatus should focus on: - correct answer bid specifications Identify two items that should be included on daily fire apparatus records - correct answer Tire condition Coolant levels Identify three exceptions to the rule that all personnel should be seated and wearing seatbelts before an emergency vehicle begins moving: - correct answer -Performing training for personnel learning to drive the tiller portion of a tractor drawn aerial apparatus -Providing patient care in the back of an ambulance -Loading the hose back onto the fire apparatus If you are driving a fire apparatus that is longer than you are familiar with, make sure you: - correct answer are more cautious when judging clearance so you don't run up on curbs and corners Identify three important reasons for knowing a fire apparatus's dimensions: - correct answer -So you don't hit any obstructions or obstacles -So you know whether it can travel under a specific overpass -So you are sure it will fit in a designated parking area Identify four skills demonstrated during the alley dock exercise: - correct answer - Operating the fire apparatus safely -Moving the fire apparatus backward within a restricted area -Interpreting spotter signals -Using side view mirrors You may need to perform a confined space turnaround: - correct answer for a reverse hose lay in a narrow street or intersection A quantity of 16.66 pounds of water equals: - correct answer 2 gallons

In a relay pumping operation, the pressure at which pumps achieve their maximum flow is: - correct answer 150psi When controlling pump valves, push handles: - correct answer can accurately control line pressure and be locked into place The pump whose rotor is mounted off-center is the: - correct answer rotary vane positive displacement pump If the FDC is totally unusable during a sprinkler or standpipe pumping operation, you should: - correct answer charge the standpipe riser at the first floor level During service testing, it is important that the water temperature be between: - correct answer 35 degrees F and 90 degrees F