Rhode Island Journeyman Plumber Exam Rev
Plumbing Code Regulation SBC-3 - ANSWER -State of Rhode
Island Plumbing Code is known as:
4' 6" Below Grade - ANSWER -Water Services Shall Be Installed
Not Less Than:
Insulated/Heated or Both - ANSWER -Piping installed in exterior
walls or areas subject to freezing must:
36" Below Grade - ANSWER -Building Sewers connected to a
public sewer shall have a minimum coverage of:
Under a water heater 6 gallons or greater that is elevated -
ANSWER -A safe waste pan shall be installed
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16

Partial preview of the text

Download Rhode Island Journeyman Plumber Exam Rev and more Exams Water and Wastewater Engineering in PDF only on Docsity!

Rhode Island Journeyman Plumber Exam Rev

Plumbing Code Regulation SBC- 3 - ANSWER - State of Rhode Island Plumbing Code is known as: 4' 6" Below Grade - ANSWER - Water Services Shall Be Installed Not Less Than: Insulated/Heated or Both - ANSWER - Piping installed in exterior walls or areas subject to freezing must: 36" Below Grade - ANSWER - Building Sewers connected to a public sewer shall have a minimum coverage of: Under a water heater 6 gallons or greater that is elevated - ANSWER - A safe waste pan shall be installed

2" deep with 2" clearance around heater - ANSWER - A safe waste pan shall be at least 10' undisturbed compacted earth - ANSWER - Water service piping and building drain/sewer shall be separated by: Water line is installed minimum 12" above sewer line at highest point - ANSWER - Water service separation distance is not required if: 50' - ANSWER - Distance for a septic tank/sewer to a private water supply(well) is: 6"below the roof with an approved fitting - ANSWER - Where frost closure is common an increase in vent size shall take place: "V" zone (subject to wave heights in excess of 3') - ANSWER - High Hazard flood zone is: 8.0% Lead - ANSWER - Lead free pipe and fittings contain less than:

15" - ANSWER - Water closets, bidets or lavatories shall have a clearance from center of fixture to wall of: 21" - ANSWER - The required clearance from front of fixture to a wall, door or other fixture is: 3" - ANSWER - Minimum size floor drains for public laundries or central washing facilities is: 1 1/2" - ANSWER - Shower waste outlets shall be minimum of: 3" - ANSWER - Minimum size removable strainer for shower compartments are: .25 inches - ANSWER - Minimum size floor drain strainer opening is: 4 pounds per square foot - ANSWER - Sheet lead shall not weigh less than:

12 ounces per square foot - ANSWER - Sheet copper shall not weigh less than: 67% - ANSWER - Urinals shall not be substituted for more than what percent of water closets? 120 degrees - ANSWER - Shower and Tub/Shower valves maximum hot water setting is: 140 degrees - ANSWER - Maximum water temperature of a tankless heater or domestic hot water heater is: 210 degrees 150 psi - ANSWER - Maximum setting of a temperature pressure and relief valve or a combination thereof is: 160 psi - ANSWER - Minimum working pressure of a domestic water service either outside or buried is: 100 psi @180 degrees - ANSWER - All hot water distribution piping and tubing shall have a minimum pressure rating of:

2" - ANSWER - Each fixture trap shall have a trap seal of not less than: 2 - ANSWER - Minimum number of roof drains in a building 10,000 square feet or less: 4 - ANSWER - Minimum number of roof drains in a building 10,000 square feet or more: 3/4" - ANSWER - Minimum size of water service pipe: Intergral - ANSWER - A clinical sink has the following trap type Vacuum Breakers - ANSWER - Flushometer valves and tanks shall have: 30 x 30 - ANSWER - Shower compartments shall not be less than

2 " - ANSWER - Commercial food waste grinder shall be connected to a minimum drain size of: 1.5" deep with a 3/4" drain - ANSWER - Water heater pan size and drain size is: 3" below the installation level - ANSWER - When rock is encountered in trenching rock will be removed to a minimum of: 4' - ANSWER - Hanger spacing for ABS pipe is: 10' head - ANSWER - Water testing of a drainage system requires a: 2.6 inches of rain per hour - ANSWER - Sizing of storm drains for Rhode Island is based on: 5 - ANSWER - The Board of Appeals consists of how many members?

There are 15 or less employees - ANSWER - Separate toilet facilities are not required when 1/4" - ANSWER - Minimum pitch for 2 1/2" piping and smaller is: 1 1/2" - ANSWER - Minimum size wet vent piping is: 1/2" OD - ANSWER - What is the minimum supply tube to a one- piece toilet? Conductor - ANSWER - What is the line in the building that carries water from the roof to the sewer called? 1 1/2" - ANSWER - What is the minimum size outlet for a shower in RI? 18" and 42" - ANSWER - What is the minimum and maximum length of a waste stack to a trap weir?

A pressure reducing backflow preventer - ANSWER - What must be installed before connecting and irrigation system to a potable water supply? Always follow the manufacturers instructions - ANSWER - Can combustible liquids that condense be allowed down the public sewer? It should be sized to the outlet of the food waste grinder - ANSWER - How should a grease trap be sized when hooking it up to a commercial food waste grinder? 4.5' underground - ANSWER - Water pipe should be buried ____________ feet underground. 10' and 2' - ANSWER - A vent which extrudes out the side of a building should be at least _______ and ______ away from doors and windows. 110 Degrees - ANSWER - In RI hot water is _________ degrees.

A branch vent - ANSWER - A vent, which connects several individual vents to a vent stack is called a _________________. 80 psi - ANSWER - At what pressure does RI require a PRV? True - ANSWER - It is required by the general contractor to have a clean restroom facilities on the job? Must hold 5 psi for 5 minutes - ANSWER - What are the requirements for an air test on a drainage system? 1 gallon - ANSWER - How many gallons does a urinal use during a flush cycle? Individually - ANSWER - A commercial food waste grinder should be trapped ___________________. 2" - ANSWER - A commercial food waste grinder should have a minimum outlet of _____________.

Air Break - ANSWER - What is required to be utilized in the waste of a clothes washer waste? Air Gap - ANSWER - Unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging. Well - ANSWER - Bored, Dug and Driven are examples of what? 24" and 30" - ANSWER - The vertical distance from the fixture outlet to the trap weir shall not exceed ________________ and the horizontal distance shall not exceed _______________ measured from the centerline of the fixture outlet to the centerline of the inlet of the trap. Half the square footage of the vertical wall - ANSWER - How much of a vertical wall should be added to the square footage calculation of a roof? 18" and 36" respectively - ANSWER - What is the clearance for rodding of a 6" pipe and an 8" pipe?

X=1/(.0408x.5625) X=1/.02295 X=43.57' - ANSWER - How many feet of 3/4 copper tubing does it take to hold 1 gallon of water? 2 - ANSWER - How many roof drains are required on a roof under 10,000 square feet? 4 - ANSWER - How many roof drains are required on a roof over 10,000 square feet? 4" - ANSWER - How many inches must the strainer of a roof drain extend above the roof? 36" below grade - ANSWER - A sewer must be buried a minimum of ____________ below grade. A Men's Room - ANSWER - A drinking fountain cannot be installed in a _____________.

6" - ANSWER - The critical level of an atmospheric vacuum breaker must be installed a minimum of __________ above the flood level rim of the fixture or device. 1 1/4" - ANSWER - The minimum size vent in RI is ____________. Yes, 6" above the highest fixture on that floor. - ANSWER - Can other fixtures vents be tied to a Clinical Service sink in a hospital? 2 1/2 x Diameter of drain size - ANSWER - Minimum distance for Air Gap? 24" - ANSWER - Maximum distance riser on drain to trap? No. Needs Approval from Inspector. - ANSWER - Is a Building Trap Legal to install? No - ANSWER - Can a Food Waste Grinder be connected to any other fixture?

1 - 1/4" - ANSWER - Phenuematic Vent size for Sewage Pumps 1/2 of Roof Area - ANSWER - How many feet does a roof ledge or vertical wall add to roof area 10 Feet - ANSWER - How far does sanitary vent have to be from property line 10' and 2' - ANSWER - Vent from window Can be How many feet from window horizontally and vertically 5PSI 15 Mins - ANSWER - Testing With Air atmospheric type vacuum breaker, a pressure type vacuum breaker or a reduced pressure principle back flow preventor. - ANSWER - What kind of backflow on irrigation setup Yearly - ANSWER - How many times to inspect back flows Install, Repairs, and Annually - ANSWER - Testing Back flows Should Happen When

1 - ANSWER - Drainage Fixture Unit on Lav 2 - ANSWER - Drainage Fixture Unit on Res. Washer Machine & Bathub 4 - ANSWER - Drainage Fixture Unit on Res. Toilet Thru Indirect Waste With air gap and have approval from authority - ANSWER - Swimming Pool Waste Shall Discharge no - ANSWER - Does Waste from emergency eye wash need a drain Pipe inside building that conveys storm water from roof to storm sewer or combined sewer - ANSWER - What is a Conductor An exterior Roof Drain - ANSWER - What is a Storm Leader