A comprehensive set of questions and verified answers related to the s12 fdny (fire department of new york) exam, updated for 2025/2026. It covers essential topics such as fire safety regulations, building evacuation procedures, and the roles of fire safety personnel. The questions address various aspects of fire prevention, suppression, and emergency response, making it a valuable resource for exam preparation. It includes topics such as alarm systems, sprinkler systems, fire extinguishers, and emergency protocols. This study guide is designed to help candidates understand the key concepts and procedures necessary for success on the fdny exam, ensuring they are well-prepared to handle fire safety responsibilities effectively. The material is presented in a question-and-answer format to facilitate learning and retention.
Typology: Assignments
1 / 21
This page cannot be seen from the preview
Don't miss anything!














"Fail Safe" when referred to in locks, means
that the door can be opened if the power fails
Where does the on-duty Building Evacuation Supervisor report when an alarm is activated?
To the Fire Command Station ( To act as Fire Safety Director when the FSD or a Deputy FSD is not required to be on duty).
"RCNY" is the abbreviation for
Rules of the City of New York
A fire alarm box is painted plain red (no stripe). When it is activated, an alarm will be sent
within the building
Which of the following is a member of the Fire Brigade?
The function of the lower check valve is to
prevent back flow into the water main.
The minimum distance of travel between fire extinguisher in a non-sprinkled class E building is
75 feet
One morning you are notified the roof gravity tank heater has burned out. Which of the following are you required to notify?
Building Owner
The function of the upper check valve is to prevent
Back flow into the gravity tank
The primary duty of a fire brigade is to
evacuate occupants of building
How often must communication to Central Station from the FSC be checked?
Monthly
If the stem extends from an OS&Y valve, it is an indication that the valve is
open
What is a "blind" shaft way?
A floor where elevator cannot stop because there are no hoist way doors.
Which of the following is NOT true about stairway pressurization?
Required in addition to sprinklers.
How often must sprinkler heads be changed?
Only after activation
Elevators will be recalled by any of the following except
Which of the following is NOT required of floor wardens?
Certificate of Fitness
The 17th floor of a fully sprinklered J1 building has an area of 17,500 sq. ft. How many 2 1/ gallons water extinguishers are required?
Which of the following is NOT the duty of the Fire Safety Director?
Provide the Fire Safety Plan
Which of the following should NOT operate in a normal manner during phase 2?
Door Open Button
A hotel is 60 ft tall and 40 sleeping rooms of which 10 are occupied. How many fire safety directors are required?
When torch operations are done, the fire watcher must check for fire
during the operations, when the operations are complete, a half hour later and a half hour after that
Diagrams require to be mounted in the hallways which show elevators, fire exits, etc. are called
floor diagrams
When a sprinkler head is said to "have fused" it means that it
was exposed to the temperature at which it was designed to activate.
Waterflow gongs are normally activated by the
What is the function of the ball drip valve?
Prevents water from freezing in the siamese connections.
Which of the following is most likely to be found at a loading dock which is unheated and generally unattended?
Automatic Dry Sprinkler System
To continue to burn a fire requires:
Fuel, Heat and Oxygen
What is the maximum amount of time that a fabric need NOT be re-flameproofed?
3 years
How many times may a fabric be laundered before it is required to be re-flameproofed?
No times.
Which of the following is NOT true about cap colors of siamese connections?
Yellow means that there are both standpipes and non-automatic sprinklers.
Which of the following is true about the main shut off valve of an automatic sprinkler system?
Must be visually inspected weekly unless equipped with a temper switch.
Which of the following SHOULD NOT be tested during Phase 2?
Emergency Stop Button
A Class C fire (energized electrical fire), when de-energized...
becomes a Class A fire. (insulation etc. are normal burning materials when not part of a live electrical circuit)
What is a "sky lobby"?
The lowest elevator lobby of elevators which do not serve the ground floor.
How often are fire suppression control valves required to be checked?
Weekly
Emergency power is required to operate all of the following EXCEPT
Emergency Lights (Battery Operated)
What is the maximum permitted length of hose at a hose station of standpipe system?
125 feet
Which of the following is required to be flameproofed?
Auditorium Curtains
In case of fire, when directed by the Fire Safety Director what should the alarm box runner do?
Go to the nearest FDNY alarm box, activate the alarm, respond verbally if necessary, and wait for fire engines to arrive.
A contractor tells you that he has to turn off the sprinkler system in order to replace some sprinkler heads. Which of the following are you NOT required to notify?
FDNY High Rise Unit
All are true about smoke detectors EXCEPT
visually inspected monthly.
All of the following must be done EXCEPT
Operational test of portable fire extinguishers
every 4th floor
During an inspection of the sprinkler system, you notice that the sprinkler heads in one of the tenant's areas have all been painted the same color as the ceiling. What should you do?
Have the sprinkler heads replaced.
At what temperature range will a sprinkler head rated "ordinary" operate?
Which statement is true?
A scissors stairs has a standpipe at every other floor.
At every elevator landing there must be a sign reading:
"In case of fire use stairs unless otherwise instructed"
While conducting a test of smoke detectors on the 26th floor, you receive alarms from smoke detectors on the 1st and 2nd floors. What would be you best course of actions?
Acknowledge the first and second floor alarms and call in an alarm to the Fire Department.
How often must fire drills be conducted in a new Class E building?
Every three months, for the first two years of occupancy. Every six months thereafter.
The emergency generator must have enough fuel to supply the total emergency power load for at least
6 hours
Where must the lobby elevator ket switch be located?
No more than 4 feet from call button
To the stairway of the floor below the fire floor
Which of the following is NOT true about the Building Evacuation Supervisor?
Is required to have a Certificate of Fitness
How many sprinkler heads must be available, and where must they be stored?
Six Spares, stored at the main shutoff valve.
Where is the fire alarm single NOT required to sound?
Building Manger's Office
Which is NOT a required feature of a Class E fire alarm system?
Sprinkler System
When are locks allowed on elevator door?
When locks can be operated by city-wide standard elevator key. (1620 and 2642)
A Class E building has five tenants on each floor. Four have 7,500 sq. ft. each, the other has 22,500 sq. ft. How many fire wardens are required on the floor?
One for each 7,500 foot occupancies, and three for the 22,500 foot area.
In an actual emergency, how would you evacuate a handicapped person?
Take him to a designated stairway.
Which of the following keys should operate the smoke purge switch?
1620 - under the direction of the Fire Department Incident Commander