Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
TCFP DRIVER PRACTICE ASSESSMENT 2026 CERTIFICATION EVALUATION EXPERT CHECKED
Typology: Exams
1 / 70
This page cannot be seen from the preview
Don't miss anything!































































◉ 300 Gallons ( 1135 L) Answer: An apparatus must carry a minimum of _______________ of water to be classified as a pumper. ◉ 400 Ft (120 m) Answer: According to NFPA 1901, what is the minimum amount of attack hose to be carried on a pumper? ◉ Initial attack fire apparatus Answer: The _____________ is usually equipped with four-wheel drive and used to fight fires in urban and rural settings. ◉ 750 gallons (2840 L) Answer: According to NFPA 1901, a pumper should be equipped with permanently mounted pump at a minimum rating of __________ of water per minute. ◉ Attic Ladder Answer: Which of the following is one type of ground ladder that must be installed by manufacturer for an apparatus to be classified as an aerial apparatus in accordance with NFPA 1901?
◉ Special service Answer: A hazardous materials apparatus or a heavy technical rescue apparatus would be considered a ___________________ fire apparatus. ◉ Initial attack fire apparatus Answer: Which type of apparatus is used to respond to small incidents such as dumpster fires, vehicle fires, and brush fires in urban settings? ◉ The jurisdiction purchasing the fire apparatus Answer: Who is ultimately responsible for conducting ongoing training to ensure proficiency with regard to the safe and proper use of the fire apparatus and its equipment? ◉ 85 ft (26-m) Answer: NFPA 1901 states that the quint shall be equipped with a minimum total complement of _____________ of ground ladders. ◉ 1000 gallons (4000 L) Answer: A mobile water supply apparatus is equipped with one or more water tanks that meet the requirements of NFPA 1901 and have a minimum certified capacity of: ◉ 400 ft (120 m) Answer: According to NFPA 1901, what is the minimum amount of attack hose to be carried on an initial attack fire apparatus?
◉ The _________________ system keeps a vehicle's axles in place and holds up the fire apparatus and its entire load. Answer: suspension ◉ Fire apparatus and equipment should be inspected at least: Answer: weekly ◉ Often, fire apparatus inspections are broken into sections. According to the text, what is the first section that should be completed? Answer: Exterior inspection ◉ An internal valve in a multistage pump that enables the user to change the mode of operation to either series/ pressure or parallel/ volume. Answer: Transfer valve ◉ A system used inside the fire apparatus bay that connects to the fire apparatus tailpipe and draws its exhaust outside the building. Answer: Extractor exhaust system ◉ An evaluation of the fire apparatus and its equipment that is intended to ensure its safe operation. Answer: Fire apparatus inspection ◉ Making sure the fire apparatus is in proper working condition, the emergency warning equipment is operating correctly, tools and
equipment are functional, and the vehicle is ready to support sustained operations are all part of: Answer: Safety ◉ When inspecting the fire apparatus, which section focuses on inspecting the portable radios, SCBA, maps, traffic vests, hearing protection, medical gloves, and box lights? Answer: Cab interior inspection ◉ True or false? According to NFPA 1451, each department shall establish in writing the condition that require the vehicle to be taken out of service. Answer: True ◉ NFPA _____________ is the standard for Automotive Fire Apparatus. Answer: 1901 ◉ What is the maximum amount of play of a steering wheel with power steering can have, prior to being repaired? Answer: 10 degrees ◉ What form refers to the document that identifies the result of previous inspections, including who performed the inspection and when? Answer: Apparatus inspection form ◉ True or False? NFPA 1901 requires the parking brake to hold the apparatus on a 10 percent grade. Answer: False
system, motor components such as belts, charging system and driver train elements? Answer: Engine compartment inspection ◉ Voltage levels of a fire apparatus may be checked by: Answer: Observing the voltage meter on the dashboard in the cab ◉ To check the tension of a belt, the driver operator should: Answer: Push against the belt in an area where there is no pulley ◉ Ten degrees of play is equivalent to ___________ inches of movement at the rim of a 20-inch steering wheel. Answer: 2 ◉ Which of the following is an example of an interior functional control switch? Answer: Map lights ◉ NFPA 1901 requires that seat belts be colored red or: Answer: Orange ◉ Tires should have at least ___________ inch of tread depth in every major groove. Answer: 4/ 32 ◉ When checking the coolant level of a fire apparatus, the driver/ operator should: Answer: Check the coolant level in a manner recommended by the manufacturer
◉ What term describes the evaluation of fire apparatus and its equipment that ensures its its safe operations? Answer: Fire apparatus inspection ◉ The _________________ lift is the greatest difference in elevation at which the fire apparatus can draft the required quantity of water under the established physical characteristics of operation. Answer: Maximum ◉ What is another name for the 70 percent test? Answer: 200 psi test ◉ If during the charging system test, the alternator output current (amps) does not reach at least ____________ of its rated output current then, the test has failed. Answer: 80% ◉ What term refers to the sum of the discharge pressure and the suction lift converted to psi or kPa when pumping at draft, or the difference between the discharge pressure and the intake pressure when pumping at a hydrant or other source of water under positive pressure? Answer: Net pump pressure ◉ The vacuum test is basically a test of the: Answer: priming system
◉ The general recommendation for water temperature during performance testing is a water temperature in the rang of 35 degrees Fahrenheit to: Answer: 90 Degrees Fahrenheit ◉ When performing a priming system test, pumps rated at less than 1500 gpm should be able to create the necessary vacuum in _________ seconds to lift water 10 feet through 20 feet of suction hose of the apparatus size. Answer: 30 ◉ During a brake test, an apparatus weighing 10,000 pounds or less should stop within: Answer: 25 feet ◉ What is the maximum percentage of pressure change in order for the compressed-air foam system to pass the test? Answer: 10% ◉ When conducting testing of an apparatus compressed- air foam system, what is the recommended pump pressure for the test? Answer: 125 psi ◉ True or False? If an apparatus is supplied with a breathing- air compressor system, that system should be tested annually by the fire dept? Answer: False
◉ When checking discharge pressure gauges for accuracy, any gauge that is off by more than ____________ must be recalibrated, repaired or replaced. Answer: 10 psi ◉ In order to receive full credit for the performance test, you must record: Answer: all information including test conditions ◉ True of False? conductivity testing is preferred to load testing when testing batteries. Answer: True ◉ What is the maximum allowable voltage drop when performing the voltage drop test of the starter on an apparatus with a 24-volt system? Answer: 0.4 volt ◉ When testing fire apparatus, water temperature are important. Warm water is defined as water at a temperature greater than: Answer: 90 Degrees Fahrenheit ◉ What is another name for the overload test? Answer: 165 psi test ◉ Nozzles suitable for service testing are usually? Answer: regular equipment on the fire apparatus
◉ What term refers to the water pressure on the discharge manifold of the fire pump at the point of gauge attachment? Answer: Discharge pressure ◉ What term refers to a group of tests conducted annually after a fire apparatus has major repairs or modifications? Answer: Performance tests ◉ During the performance test, the pump should be subjected to 10 minutes of pumping at ___________ of the rated capacity at 250 psi net pump pressure. Answer: 50% ◉ Pump _____________ controls might include electrical, pneumatic, or mechanical components working individually or in combination to shift the pump drive system into and out of pump mode. Answer: shift ◉ Tests conducted after a fire apparatus has been put into service to determine if its performance meets predetermined specifications or standards. Answer: Service Testing ◉ The flow rate to which the pump manufacturer certifies compliance of the pump when it is new. Answer: Rated capacity
◉ The water pressure on the discharge manifold of the fire pump at the point of gauge attachment. Answer: Discharge pressure ◉ The pressure on the intake passageway of the pump at the point of gauge attachment. Answer: Intake pressure ◉ The temperature of the surrounding medium, it typically refers to the temperature of the air in which a structure is situated or a device Answer: Ambient air temperature ◉ Insufficient pressure when operating a center-fugal pump could be the result of: Answer: Pumping too much water for the available power ◉ When checking the governed engine speed, the engine speed should be within +/- ___________ rpm of the governed engine speed when the fire apparatus was new. Answer: 50 ◉ What type of apparatus test is required for aerial emergency power sources? Answer: Solenoid and relay test ◉ Which method of testing an apparatus foam system is preferred for testing systems containing aqueous film forming foam, alcohol- resistant foam, or 1% or less foam concentrate? Answer: Determining the foam percentage with a conductivity meter
◉ What is the minimum speed the apparatus must be traveling to complete the road test? Answer: 50 mi/h ◉ Which of the following is the correct order of operations for performance testing? Answer: The weight verification test, the braking system test, the parking brake test, and the road test ◉ Before beginning any performance tests on fire apparatus pumps, all of the following environmental conditions must be determined and recorded prior to and immediately after the pump performance testing EXCEPT: Answer: humidity ◉ When performing a vacuum test, the vacuum inside a pump or suction hose should not drop in excess of ________________ in __________ minutes. Answer: 10 in; 5 ◉ In a pressure control test, the pressure control device should be tested at intervals of 150 psi, 90 psi, and: Answer: 250 psi ◉ How often should pump tests be performed Answer: Annually ◉ What term refers to a device that allows the bypass of fluids to limit the pressure in a system? Answer: Relief valve
◉ Which type of test is basically a test of the priming system, specifically the tightness of the pump, including its valves and fittings. Answer: Vacuum ◉ When backing a fire apparatus, the driver/ operator should always use a _________________ if available. Answer: spotter ◉ A 360-degree inspection refers to a(n): Answer: Complete walk- around inspection of the unit before you go on a response ◉ What is the normal operating pressure for an air braking system on most fire apparatus? Answer: 100-120 psi ◉ While driving a fire apparatus around an emergency scene, the driver/ operator may be forced to maneuver the fire apparatus in a tight area and around obstacles that are hanging down, such as trees or building signs. NFPA 1002 requires the driver/ operator to successfully complete a ________________ exercise to stimulate this challenge. Answer: Diminishing clearance ◉ While responding to an emergency, the driver/ operator may accidentally pass an intended turn, forcing him or her to turn around. NFPA 1002 requires the driver/ operator to successfully complete a ____________________exercise to simulate this challenge. Answer: Confined space turnaround
◉ For most fire depts, the largest number of fire apparatus accidents is related to: Answer: Backing the apparatus ◉ In accordance with NFPA 1901, a fire apparatus wiht a completely discharged air system must be able to move within _________________ of start up. Answer: 1 minute ◉ The driver / operator must understand that a speedy response is achieved by adhering to many guidelines including: Answer: driving safely and efficiently ◉ True of False? NFPA 1901 requires that all seats on fire apparatus be enclosed and provided with an approved seat belt: Answer: True ◉ How would a driver/ operator disconnect all electrical power to a fire apparatus to prevent discharge while it is not in use? Answer: Use the battery selector switch ◉ When returning to the station from an emergency, the driver/ operator operating the fire apparatus should __________________________ once the fire apparatus is on the ramp in front of the station. Answer: Allow the engine to cool down as much as possible
◉ When backing a fire apparatus, the driver/ operator should immediately stop the apparatus when: Answer: The driver/ operator loses sight of the spotter ◉ In performing the serpentine exercise, the driver is permitted to: Answer: Use a spotter ◉ How long should a fire apparatus be at idle prior to shutting down the engine? Answer: 3-5 minutes ◉ what are the dimensions of the boundary used for the confined space turnaround exercise? Answer: 50 ft x 100 ft ◉ The switch that engages the starter motor for cranking? Answer: Starter Switch ◉ The care exercised by a reasonably prudent person under the same circumstances? Answer: Due regard ◉ A series of checks that an electrical system completes to ensure that all of the systems are functioning properly before the fire apparatus is started: Answer: System check sequence