






Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
A series of questions and answers related to firefighting practices and safety protocols. It covers topics such as the standard for firefighter professional qualifications, truck/ladder company functions, osha regulations, incident command systems, ppe, high-rise fires, forcible entry, rope strength, radio communication, scba usage, and fire hose handling. The material is designed to test and reinforce knowledge of essential firefighting skills and safety procedures, making it a valuable resource for training and certification preparation. It also includes questions about fire behavior, extinguishing agents, and tool usage. Useful for university students, high school students and lifelong learners.
Typology: Exams
1 / 10
This page cannot be seen from the preview
Don't miss anything!







NFPA 1001 is the - Answers -Standard for Firefighter Professional Qualifications One of the primary functions of the truck/ladder company is - Answers -performing forcible entry to fire scene buildings OSHA may establish regulations governing fire department activities such as - Answers -health and safety In the ICS, the functional area responsible for all incident activities, including the development and implementation of strategic decisions, is - Answers -Command What normal body cooling mechanism is lost when wearing PPE? - Answers - Evaporation of perspiration What is one aspect of high rise fires that is especially draining of energy? - Answers - walking up many flights of stairs in PPE A _______ permits firefighters to gain access during an emergency - Answers -key box/lock box In kernmantle rope, the kern or core of the rope accounts for approximately _____ of its strength - Answers -75 percent The combination of knots recommended to hoist a pike pole includes - Answers -a clove hitch and half hitches The order of rank and authority in the fire service describes - Answers -chain of command The street, or address side of the structure is termed - Answers -Division A The ratio of the mass of a given volume of liquid compared with the mass of an equal volume of water at the same temperature is - Answers -specific gravity Life safety rope should be stored in - Answers -coils in rope bags Toxic atmospheres due to smoke and heat are called - Answers -immediately dangerous to life and health Which of the following has the highest priority for radio transmission? - Answers - Emergency traffic from a unit working at a fire or rescue
The telecommunicator's first responsibility is to - Answers -obtain the information that is required to dispatch the appropriate units to the correct location Before transmitting any information over the fire department radio, a fire fighter should - Answers -listen to be sure the channel is not being used When using positive pressure SCBA, a poor seal between the face piece and the firefighter's face is - Answers -dangerous, because it is depleting the air supply more quickly The bypass valve on a SCBA is used - Answers -in emergency situations involving a malfunctioning regulator The first noticeable sign of oxygen deficiency is - Answers -increased respiratory rate and impaired muscular coordination Four hazardous atmospheres that firefighters are likely to encounter at a fire are - Answers -super heated air, toxic gases, oxygen deficiency, and smoke Trapped firefighters awaiting rescue will use less air if they - Answers -control their breathing The primary function of the bypass valve on the SCBA is - Answers -for use if the regulator fails The proper position of the bypass valve on positive pressure SCBA under normal conditions is - Answers -fully closed Hypoxia is - Answers -a deficiency of oxygen inhaled toxic gases can directly cause - Answers -disease of the lung tissue What is incorrect about the two SCBA types in fire service use? - Answers -The closed circuit type is commonly used for structural firefighting The purpose of the PASS device is to - Answers -sound and alarm if a firefighter is motionless for a set period of time At the beginning of the shift, the firefighter should make sure their SCBA is at least __% full - Answers - Once overhead doors have forced, they should be - Answers -blocked open Which tool is a pulling tool? Crowbar, flathead ax, pike pole, halligan - Answers -pike pole
Which of the following is not an appropriate procedure or consideration before applying foam - Answers -the use of foam is limited to combustible liquids the coupling on the high pressure hose that is attached to an SCBA cylinder should be - Answers -hand tight Which of the following is true regarding SCBA? - Answers -All scba face pieces must be fit tested A least desirable point for forcible entry is - Answers -A revolving door A personnel accountability system tracks which firefighters are assigned to each vehicle and - Answers -Each crew's assignment A hose roller is - Answers -A curved metal frame that fits over the edge of a roof or windowsill Solid stream handlines are designed to be operated at a nozzle pressure of ____ psi - Answers - Which of the following statements regarding the accordion load is incorrect - Answers -It is the preferred way to load large diameter hose What is the safest and best way to advance a hose line up a ladder? - Answers - Charged What is a recommended practice to prevent mechanical fire hose damage? - Answers - Open and close nozzles, valves, and hydrants slowly The usual cause of collapse of open web steel joist is the - Answers -Amount of heat generated by the fire in a structure Hidden fires can be detected by - Answers -Feeling it with the back of the hand What feature is required on a fire department connection that allows a ff to charge the first hose line prior to connecting the second - Answers -Clapper valve A blue circle with a letter designation in the center would indicate an extinguisher for use on ___ fires - Answers -Class c Dry powder extinguishers are rated for use on ____ metals - Answers -Class D Halon fire extinguishers are primarily designed for use on ____ fires - Answers -Class B and C
A blue circle with a letter designation in the center would indicate an extinguisher is rated for use on ____ fires - Answers -Class C Pump tank extinguishers are used to apply - Answers -Water When drying synthetic rope, keep it - Answers -Out of sunlight _____ should be applied to wooden tool handles to prevent roughness and warping - Answers -Boiled linseed oil The main advantage of the donut roll - Answers -Both ends are available on the outside of the roll Hose is unloaded at the scene of a fire and the pumper proceeds to the water source this is - Answers -A forward lay About how much of a kernmantle rope's strength is provided by the mantle - Answers - 25 to 30 percent The strategy of an incident which of the following - Answers -Offensive and defensive mode What does automatic number identification feature of enhance 911 do? - Answers - Show the caller's phone number What is NOT a limitation of a ff's ability to use SCBA - Answers -Oxygen cylinder size When filling an SCBA cylinder, the cylinder must be - Answers -Placed in a fragmentation containment or other shielded device A cutting torch has a flame temperature of - Answers -5000 degrees f During which of the following operations are personnel allowed to be outside the cab while an apparatus is in motion? - Answers -hose loading An informal discussion with incident responders conducted after the incident is known as: - Answers -defusing What is the minimum noise level, in decibels, which requires firefighters in the United States to wear hearing protection? - Answers - The instantaneous explosion of superheated gases that occurs when oxygen is introduced into an oxygen-depleted confined space is known as a: - Answers -backdraft Which of the following best represents nonflaming or smoldering combustion? - Answers -fire triangle
What is the minimum number of firefighters for a search team? - Answers - What type of carabiner is best for use in rescue operations? - Answers -positive locking type The priority for searching a multi-story building is the fire floor, the floor immediately above the fire floor, and the: - Answers -topmost floor If needed, which of the following tools could be used to remove a laminated windshield in a vehicle? - Answers -air chisel What is the proper and safe position for an acetylene cylinder that is part of a cutting torch kit? - Answers -secure and upright What is the most common use of a chain saw during fire ground operation? - Answers - ventilation Why should the use of a cheater on a prying tool be avoided? - Answers -the tool can break and injure the firefighter What is the best method for sharpening the cutting edge of an axe? - Answers -by hand What is the best lubricant for unprotected metal surfaces? - Answers -light machine oil What is the device used to prevent a patio sliding door from being forced open? - Answers -burglar block Which type of overhead door is generally easiest to force unless it is motor driven? - Answers -sectional What are the devices attached to the inside of the beams on fly sections used to hold the fly section in place? - Answers -pawls Which type of ladder is used to gain access to attics and can be carried in narrow hallways? - Answers -folding ladder An extension ladder with the fly sections fully retracted is in the: - Answers -bedded position Where should the ladder tip be placed when using a ladder to perform a rescue from a window opening? - Answers -tip of ladder just below windowsill Which carry is typically used for a 35 ft. extension ladder? - Answers -three firefighter flat shoulder carry
What is the minimum distance of separation between a ladder and energized electrical equipment? - Answers -10 feet What is the proper location for the fly section of a metal ladder when the fly section(s) are extended? - Answers -fly out The tendency of gases to form into layers, according to temperature, with the hottest gases at the top is known as: - Answers -thermal layering How does ventilation control fire spread during a structural fire? - Answers -The release of smoke and heat reduces the rate at which fire will spread. What is a sign of a potential backdraft? - Answers -smoke stained windows What is the typical construction used for flat roofs on commercial buildings? - Answers - joists covered with decking What type of ventilation is used to stop the spread of a fire in a long, narrow structure? - Answers -trench ventilation Which type of valve used as a control valve for a sprinkler system indicates whether the valve is open or closed by the position of the center screw? - Answers -OS&Y Valve What is the difference between soft sleeve and hard suction hose? - Answers -soft suction hose must be used with pressurized water sources What is the best method for preventing mechanical damage to fire hose when the hose vibrates near the pumper? - Answers -chafing blocks What is used to make the connection between the male and female ends of a fire hose watertight? - Answers -swivel gasket What type of valve is used in pumper discharges and gated wyes? - Answers -ball valve What type of valve incorporates a flat baffle that turns 90 degrees? - Answers -butterfly valve _________________ is the quantity of heat absorbed by a substance at the point at which it changes from a liquid to a vapor. - Answers -latent heat of vaporization Water will expand approximately ________ times its original volume when heated to 212°F (100°C). - Answers - Most master stream solid-stream devices are operated at _____ psi. - Answers - The designed operating pressure for most combination nozzles is: - Answers -100 psi
Those operations that aid in reducing primary and secondary damage during fire fighting operations is the definition of: - Answers -salvage What should be developed for buildings with high-value contents that are susceptible to water and smoke damage? - Answers -Special preincident plans A common obstacle to efficient salvage operations in commercial occupancies and warehouses is a lack of: - Answers -skids or pallets under stock What percentage of convictions occurs as a result of suspected incendiary fires? - Answers -2% The cause of a fire is a combination of the fuel that is ignited, the form and source of the heat of ignition, and: - Answers -an act or omission that brings them together Observations made by firefighters upon arrival at the fire scene include wind direction and velocity, the presence of burglary tools, and: - Answers -familiar faces in the crowd of bystanders ______________ may produce abnormally high heat intensity and may be confused with the use of accelerants. - Answers -Polyurethane A ____________________________ is any location or facility at which 9-1-1 calls are answered either by direct calling, rerouting, or diversion. - Answers -Public Safety Answering Point (PSAP) A predetermined number of fire units assigned to respond to an emergency is known as: - Answers -alarm assignment Two common emergency signals are broadcasting a radio message ordering the evacuation and: - Answers -Sound the audible warning devices on apparatus at the scene. Which of the following components of a fire is most manageable through fire prevention? - Answers -heat source Which of the following will cause mechanical heat energy? - Answers -machine bearings What fire hazard arises from the processes or operations peculiar to an individual occupancy? - Answers -special fire hazard Which of the following code violations must be corrected immediately by the property owner? - Answers -obstructed exit door