Texas Professional Home Inspector Exam Questions and Correct Verified Solutions Latest Update This Year – Just Released Comprehensive Study Guide and Practice Review This comprehensive study resource is designed for candidates preparing for the Texas Professional Home Inspector examination and seeking to strengthen their understanding of residential property inspection standards, building systems evaluation, and regulatory compliance requirements. The document provides structured practice questions with detailed explanations to support mastery of inspection principles and readiness for professional licensing. The material focuses on core competencies required for professional home inspectors in Texas, including structural assessment, systems evaluation, defect identification, and compliance with state inspection regulations. It emphasizes practical application of inspection standards used in residential property evaluations and reporting practices aligned with professional licensing
Typology: Exams
1 / 108
This page cannot be seen from the preview
Don't miss anything!





























































































Texas Professional Home Inspector Exam – 3 00 Practice Questions Question 1 What is the minimum passing score required for the state portion of the Texas Professional Home Inspector exam? A) 70% B) 75% C) 80% D) 85% Answer: A Rationale: According to TREC regulations, professional inspector applicants must achieve a score of at least 70% on the state portion of the examination. The national portion uses a different scoring method. Examination results are valid for one year from the date the exam is passed.
Question 2 How many questions are on the National Home Inspector Examination (NHIE)? A) 100 questions with no unscored items B) 150 questions with 25 unscored C) 200 questions with 25 unscored D) 250 questions with 50 unscored Answer: C Rationale: The National Home Inspector Examination consists of 200 multiple-choice questions , with 25 questions that are not scored (pretest questions). Candidates have four hours to complete the exam. The state portion consists of 30 questions with a separate fee. Question 3 What is the total number of hours of TREC-approved education required before a candidate is eligible to take the National portion of the Texas Professional Home Inspector exam? A) 90 hours B) 110 hours C) 140 hours D) 154 hours Answer: D
C) 32 hours D) 40 hours Answer: C Rationale: Professional Inspector license renewal requires 32 hours of continuing education , which includes 24 hours of qualifying hours (no more than 16 on one subject) and 8 hours of non-elective coursework (4 hours of Legal and Ethics and 4 hours of Standards of Practice Review). Question 6 What is the required minimum liability insurance for a Texas Professional Home Inspector? A) $50, B) $100, C) $300, D) $500, Answer: B Rationale: A Professional Inspector must provide proof of professional liability insurance of $100,000. This is required for licensure. Question 7
According to the Texas Standards of Practice, what is the time requirement for delivering an inspection report? A) 24 hours B) 48 hours C) 3 days D) 5 days Answer: C Rationale: The Texas Standards of Practice require that an inspection report must be delivered within 3 days of the inspection , unless otherwise agreed upon by the parties. Question 8 Which of the following is NOT a required module for Texas Professional Inspector exam eligibility? A) Property and Building Inspection Module I B) Property and Building Inspection Module II C) Texas Standards of Practice Module D) Texas Finance and Real Estate Appraisal Module Answer: D Rationale: Before the applicant is eligible to take the national portion of the examination, the applicant must submit evidence of completion of Property and Building Inspection Module I,
C) $1,000 - $5,000 per day D) $5,000 - $10,000 per day Answer: B Rationale: Penalties for violations include: $100 to $1,500 per violation per day for form and administrative violations; $500 to $3,000 per violation per day for Standards of Practice violations and negligence; and $1,000 to $5,000 per violation per day for intentional acts, fraud, deceit, or lack of E&O insurance. Question 11 What must happen if an applicant fails the exam three consecutive times? A) They must wait 6 months before reapplying B) They must submit evidence of completing additional qualifying education before reexamination C) They are permanently ineligible for licensure D) They must retake all 154 hours of coursework Answer: B Rationale: If the applicant fails the examination three consecutive times, the applicant may not apply for reexamination or submit a new license application unless the applicant submits evidence to the Commission that they have successfully completed additional qualifying education after the date of the third failed examination.
Question 12 What is the maximum number of residential dwelling units an inspector may be responsible for under the Texas Standards of Practice? A) 2 B) 3 C) 4 D) 6 Answer: C Rationale: The maximum number of residential dwelling units that a Texas inspector may be responsible for under the Texas Standards of Practice is 4 units. This is a limitation on inspection scope. Question 13 When may an inspector repair or upgrade a property that they have inspected? A) Immediately after completing the inspection report B) After 6 months C) After 12 months D) Never Answer: C
Answer: B Rationale: TREC has contracted with Pearson VUE to administer the state and national examinations. Candidates schedule exams online through Pearson VUE's website. Question 16 What is the fee for taking the National Home Inspector Examination? A) $ B) $ C) $ D) $ Answer: C Rationale: The National Home Inspector Examination fee is $199 when scheduling online through Pearson VUE. The state exam is an additional $55, for a total of $254. Question 17 According to TREC rules, what is the minimum slope required for a horizontal waste pipe? A) 1/8 inch per foot B) 1/4 inch per foot for pipes less than 3 inches C) 1/2 inch per foot for all pipes D) 1 inch per foot for pipes over 4 inches
Answer: B Rationale: A horizontal waste pipe should slope 1/4 inch per foot for pipes less than 3 inches and 1/8 inch per foot for pipes greater than or equal to 3 inches. Proper slope ensures self-scouring flow and prevents clogs. Question 18 What is the required height for a guardrail on a deck that is 30 inches or more above grade? A) 30 inches B) 36 inches C) 42 inches D) 48 inches Answer: B Rationale: A deck 30 inches or more above grade requires a guardrail with a minimum height of 36 inches from the deck surface. Balusters and openings should not exceed 4 inches in diameter. Question 19 What is the maximum spacing allowed between balusters on a deck guardrail? A) 3 inches B) 4 inches
What is the minimum overlap required for vertically installed fiber cement siding? A) 1/2 inch B) 3/4 inch C) 1 1/4 inches D) 2 inches Answer: C Rationale: The minimum overlap for vertically installed fiber cement siding is 1 1/4 inches. Blind nailing is recommended to ensure a clean finish and proper weather resistance. Question 22 What is the primary concern with a double-sided key-lock deadbolt on an exterior door? A) It is not durable enough B) It is a fire safety and egress hazard C) It cannot be installed in Texas D) It is too expensive Answer: B Rationale: All means of egress must be operable from the inside without special knowledge or tools. A keyed lock requiring a key to exit is considered a dangerous safety hazard in case of emergency.
Question 23 What is the maximum difference allowed between any two riser heights in a single flight of stairs? A) 1/4 inch B) 3/8 inch C) 1/2 inch D) 5/8 inch Answer: B Rationale: The difference between any two riser heights, treads, or nosings in a flight of stairs should be no more than 3/8 of an inch. Variation in riser height creates a significant trip-and- fall hazard. Question 24 What is the maximum riser height for a residential stairway? A) 7 inches B) 7 3/4 inches C) 8 inches D) 8 1/4 inches Answer: B
Rationale: Foundation anchor bolts shall be at least 1/2 inch in diameter and shall extend a minimum of 7 inches into the concrete or grouted cells of concrete masonry units. Question 27 What is the correct orientation for floor joists during installation? A) Crown down B) Crown up C) Flat side up D) Oriented randomly Answer: B Rationale: Floor joists are installed with the crown facing upward. This allows the natural curvature to compensate for loads and prevents sagging over time. Question 28 What is the maximum allowable water pressure that should be reported as deficient? A) 60 PSI B) 80 PSI C) 100 PSI D) 120 PSI Answer: B
Rationale: Water pressure in excess of 80 PSI should be reported as deficient. High water pressure can cause damage to plumbing fixtures and appliances and should be corrected with a pressure-reducing valve. Question 29 What is the purpose of a dielectric union? A) To connect copper pipe to galvanized pipe while preventing corrosion B) To provide electrical grounding for the plumbing system C) To increase water pressure in the system D) To reduce water hammer Answer: A Rationale: A dielectric union is used to connect two dissimilar metal pipes (such as copper and galvanized steel) to prevent galvanic corrosion. It separates the metals with a non-conductive barrier. Question 30 What is the purpose of a drip screed (weep screed) in stucco construction? A) To provide structural support B) To release moisture at the base/bottom of stucco walls
What is the minimum conductor size for a grounding electrode? A) #4 copper B) #6 copper C) #8 copper D) #10 copper Answer: A Rationale: The grounding electrode conductor must be at least #4 copper or equivalent. It is essential for providing a safe path to ground in the event of a fault. Question 33 What is the minimum size of a grounding electrode? A) 4 feet below grade B) 6 feet below grade C) 8 feet below grade D) 10 feet below grade Answer: C Rationale: A grounding electrode should be a minimum of 8 feet below grade. This ensures it is in contact with sufficient moisture to provide an effective ground path. Question 34
What is the minimum clearance for NM cable (Romex) from framing members when run through studs? A) 1/4 inch B) 1/2 inch C) 1 1/4 inches D) 2 inches Answer: C Rationale: NM cable should have a nail guard when run closer than 1 1/4 inches from framing members. This prevents nails or screws from penetrating and damaging the cable. Question 35 What is the minimum diameter of a basin for an egress window? A) 22 inches by 30 inches B) 24 inches by 36 inches C) 36 inches by 36 inches D) 40 inches by 40 inches Answer: C Rationale: An egress window must have a minimum clear opening of 36 inches by 36 inches. The window must also be a minimum of 44 inches from the floor and have a sill height no greater than 44 inches.