โ—‰ โ—ฆ Video analytics. Answer: technologies, such as object detection,
people counting, and perimeter intrusion detection, analyze camera
feeds in real-time to identify specific events or behaviors. These
analytics can automatically detect suspicious activities and generate
alerts, improving incident response and reducing false alarms.
โ—‰ โ—ฆ Facial recognition: Answer: technology can identify individuals
by analyzing their facial features. It can be used for access control,
identifying known persons of interest, or creating watchlists for
potential threats.
โ—‰ โ—ฆ License plate recognition (LPR):. Answer: technology reads and
recognizes license plates, enabling automated vehicle tracking and
identification. It is useful for parking management, traffic control,
and enhancing security
in restricted areas.
โ—‰ โ—ฆ Heat mapping:. Answer: analyzes camera footage to identify
areas with high activity or congestion. This information can be used
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download TN CLOSED-CIRCUIT TELEVISION SYSTEMS QUALIFYING AGENT PRACTICE EXAM 2026 COMPLETE STUDY GU and more Exams Public Policy in PDF only on Docsity!

TN CLOSED-CIRCUIT TELEVISION SYSTEMS

QUALIFYING AGENT PRACTICE EXAM 2026

COMPLETE STUDY GUIDE WITH VERIFIED

ANSWERS

โ—‰ โ—ฆ Video analytics. Answer: technologies, such as object detection, people counting, and perimeter intrusion detection, analyze camera feeds in real-time to identify specific events or behaviors. These analytics can automatically detect suspicious activities and generate alerts, improving incident response and reducing false alarms. โ—‰ โ—ฆ Facial recognition: Answer: technology can identify individuals by analyzing their facial features. It can be used for access control, identifying known persons of interest, or creating watchlists for potential threats. โ—‰ โ—ฆ License plate recognition (LPR):. Answer: technology reads and recognizes license plates, enabling automated vehicle tracking and identification. It is useful for parking management, traffic control, and enhancing security in restricted areas. โ—‰ โ—ฆ Heat mapping:. Answer: analyzes camera footage to identify areas with high activity or congestion. This information can be used

to optimize space utilization, improve crowd management, and enhance security planning. โ—‰ โ—ฆ Integration with other security systems:. Answer: CCTV systems can be integrated with other security systems, such as access control or intrusion detection systems, to provide a comprehensive security solution. This integration allows for a unified view of security events and coordinated responses across different systems โ—‰ Cables that can be used for CCTV design. Answer: CAT 5e to CAT 7 are usually used for CCTV Design โ—‰ Scope. Answer: covers the design and inspection of fire detection and alarm systems, including communication and emergency voice evacuation, along with installation requirements. โ—‰ Purpose. Answer: is to define the means of signal initiation, transmission, notification, annunciation, emergency two-way communication, and emergency voice evacuation in fire detection and alarm systems. โ—‰ Application. Answer: All installations of automatic fire detection and alarm systems shall comply with the general requirements, the design and application, installation, maintenance, testing, and inspection of fire detection and alarm systems.

โ—‰ CENTRAL STATION. Answer: An entity controlled by a person or corporation whose business is the monitoring and maintaining of supervised alarms automatically transmitted to it by the FDAS. โ—‰ CONVENTIONAL DEVICES. Answer: An FDAS component, such as a smoke detector, heat detector, or manual fire alarm station, that does not have an electromechanical or software address that gives it a discrete identity. โ—‰ CONVENTIONAL SYSTEM ; alarm zones. Answer: A system with a conventional fire alarm control panel that is wired in a way that divides the protected building into parts, which are called ________. โ—‰ DETECTOR. Answer: A device that is used to sense the products of fire, such as smoke, heat, flame, or carbon monoxide. โ—‰ Smoke Detector. Answer: A detector that detects particles of combustion, whether visible or invisible. โ—‰ Heat Detector. Answer: A detector that detects abnormally high temperature, an abnormally fast rate of temperature rise, or both. โ—‰ Multi-criteria Detector. Answer: A detector that contains 2 or more sensors that track the corresponding products of fire and

transmit signals to the FACP, which shall mathematically evaluate with algorithms to determine when an alarm signal is warranted. โ—‰ Duct Detector. Answer: A smoke detector, using sampling tubes, that senses smoke in the air circulating within air-conditioning or ventilating ducts. โ—‰ Beam Detector. Answer: A smoke detector that senses smoke along a continuous path, usually installed in high-ceiling areas. โ—‰ Flame Detector. Answer: A detector that senses and detects the radiant energy emitted by a flame. โ—‰ Air Sampling-type. Answer: A detector consisting of a piping layout or network that runs from the detector to the protected area/s. โ—‰ Carbon Monoxide Detector. Answer: A detector that senses and detects abnormally high levels of carbon monoxide. โ—‰ EMERGENCY COMMUNICATIONS SYSTEM. Answer: A sub-system of an FDAS that broadcasts the existence of a fire or an emergency or communicates information necessary to facilitate an appropriate action.

โ—‰ FIRE COMMAND CENTER. Answer: The room wherein the FACP and other life safety system are located to display and monitor all fire alarms and system troubles, and from which all output functions are automatically and manually connected. โ—‰ MANUAL FIRE ALARM STATION. Answer: An FDAS component that is manually operated to initiate a fire alarm signal. โ—‰ NOTIFICATION APPLIANCE. Answer: An FDAS component such as bell, horn, speaker, strobe, or text display that provides audible or visible outputs, or both. โ—‰ Audible Notification Appliance. Answer: A notification appliance that warns by the sense of hearing. โ—‰ Visible Notification Appliance. Answer: A notification appliance that warns by the sense of sight. โ—‰ Tactile Notification Appliance. Answer: A notification appliance that warns by the sense of touch or vibration. โ—‰ PERSONNEL. Answer: People, who install, maintain, service, test, and/or inspect fire detection and alarm system.

โ—‰ Maintenance & Service Personnel. Answer: Individuals who perform cleaning, replacements of equipment, and other maintenance work. โ—‰ Testing Personnel. Answer: Individuals who perform physical checks, tests, and procedures to determine whether the system performs as required for acceptance. โ—‰ Inspection Personnel. Answer: Individuals representing the AHJ who perform physical checks to determine whether the system functions and performs as required, as partial compliance for issuance of Fire Safety Inspection Certificate. โ—‰ POWER SUPPLYT. Answer: he source of electricity that provides power needed to operate the FACP, and consequently all devices connected it. โ—‰ Primary Power SupplyI. Answer: t is the 220VAC power voltage from the electrical utility company. Within the FACP it is converted to the system voltage of 24VDC. โ—‰ Secondary Power Supply. Answer: When there is failure of the primary power supply, the batteries (serving as the secondary power supply) automatically switch over to provide uninterrupted power to the system.

1 meter or less 1 sq. m. Answer: FILL IN THE BLANKS Areas where detection is NOT REQUIRED ยท The spaces under raised floor with a height of ____ or less ยท Toilet and or bathroom less than __ sq. m ยท The spaces above drop ceiling with a height of __ meter or less ยท Exhaust ducts from toilets/ bathrooms ยท Concealed spaces under the roof with a height 0f __ ยท Any walk-in type enclosure with a floor area not more than ____ ยท Covered paths ยท Areas under structures such as platforms and ducts โ—‰ 600mm 1 meter 1 meter. Answer: Areas where detection is REQUIRED ยท Spaces under floor more than ______ in height ยท Space above drop ceiling more than ______ in height ยท Concealed spaces under the roof more than ______ in height ยท Stairwells ยท Return air ducts of air conditioning system ยท Tunnels linking two or more buildings ยท Vaults

ยท Vertical Shafts โ—‰ โœ“ Automatic detection, and manual fire alarm signal initiation โœ“ Activation of fire alarm notification appliances โœ“ Emergency communications system โœ“ Activation of annunciators โœ“ Monitoring of abnormal conditions in fire suppression system โœ“ Activation of fire safety functions โœ“ Transmission of alarm signal to an off premises Central Station. Answer: The FDAS should have one or more of the following functions: โ—‰ attached garages. Answer: ร˜ Carbon Monoxide Detector Shall be installed for dwelling units with ______ and for units with a permanently installed for open parking garages and mechanically ventilated garages. โ—‰ spectral response. Answer: For Flame detectors, selection shall be based on the matching of ______ of the detector to the spectral emissions of the fire to be detected to avoid nuisance alarms

ยท Hotels ยท Residential buildings or condominiums with floor area more than 25,000 sq. m or with more than 25 floors ยท Buildings with floor area greater than 15,000 sq. m or with more than 15 floors. Answer: A one-way emergency communication sub- system shall be required for the following facilities โ—‰ 10 zones 200 automatic detectors.. Answer: Two-way telephone communication sub-system shall be required for conventional system with FACP of more than _____ and for addressable and semiaddressable system with more than _____ โ—‰ 1.4 m. Answer: Manual Detection It is achieved through the manual activation of fire push or pull stations installed at a height of ____ above floor and shall be easily seen and is accessible. It is usually colored red โ—‰ A registered Professional Electronics Engineer (PECE) Experienced in the proper design, application, installation, and testing of FDAS as certified by IECEP. Answer: Personnel Qualifications

FDAS designer shall have the following qualifications: โ—‰ Philippine Electrical Code and the Revised Fire Code of the Philippines 2008. Answer: Installation of FDAS shall comply with the requirements of the ________ and its implementing rules and regulation โ—‰ โ€ข Testing the insulation resistance and continuity of wires

  • Verification of installed devices
  • Operation and response of FDAS
  • Testing the operation of initiating devices
  • Measuring sound pressure level generated by notification devices. Answer: System Testing The FDAS shall be subjected to the following test conforming to applicable standards: โ—‰ F - shall be provided. Answer: Operation and Maintenance manuals of the equipments as well as As-built in drawings shall not be provided to the user before final inspection by the Bureau of Fire Department. A copy shall be on hand at the Fire Command Center or near the FACP at all times T or F

T or F โ—‰ F - should be. Answer: The owner of the protected building shall be responsible in ensuring that the installation is tested. The results should not be recorded in the log records. T or F โ—‰ T. Answer: โœ“ After the first year of the initial acceptance, the installation shall be inspected by the AHJ. Prior to this inspection, the system shall be tested and certified by a personnel T or F โ—‰ A complete set of operation and maintenance manuals of the manufacturer covering all equipment used in the system. A complete set of as-built drawings A written sequence of operation Dully filled out Record of Completion Log record book. Answer: What are the records need for fdas? โ—‰