PJM Generation Dispatch Exam Flashcards with Solutions, Exams of Project Management

Flashcard questions and complete solutions related to pjm (pjm interconnection) generation dispatch. It covers topics such as restoration process, black start restoration, system blackouts, and communication paths during restoration. The questions address various scenarios and requirements for black start units, dynamic reserves, and restoration strategies. This material is useful for individuals preparing for exams or seeking to deepen their understanding of power system restoration and dispatch operations within the pjm framework. It provides practical insights into the challenges and considerations involved in maintaining grid stability and reliability.

Typology: Exams

2024/2025

Available from 09/27/2025

prof-Emily
prof-Emily 🇺🇸

1K documents

1 / 62

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
PJM GENERATION DISPATCH EXAM FLASH
CARDS QUESTIONS WITH 100% COMPLETE
SOLUTIONS.
Which,of,the,following,statements,is,correct,concerning,PJM,assuming,frequency,control,of,the,restorati
on,process?
A),PJM,assumes,control,once,an,external,transmission,tie,has,been,established.
B),Once,an,Area,Control,Error,can,be,calculated,,PJM,will,assume,control.
C),Whenever,it,becomes,too,much,of,a,burden,for,any,one,Transmission,Owner,within,the,RTO
D),Whenever,the,Transmission,Owners,within,the,RTO,agree,to,let,PJM,control,the,process.,,ANS,-
,C),Whenever,it,becomes,too,much,of,a,burden,for,any,one,Transmission,Owner,within,the,RTO
During,black,start,restoration,,priority,access,to,cranking,power,should,be,given,to:
A),Hot,units,that,can,return,to,service,immediately.
B),Combustion,turbines,in,areas,where,the,initial,disturbance,occurred
C)Units,with,black,start,capability
D),Hydro,Units,,ANS,-,A),Hot,units,that,can,return,to,service,immediately.
During,a,restoration,,if,you,are,presented,with,the,opportunity,to,re-
connect,with,the,Eastern,Interconnection,,you,should:
A)Not,pursue,this,opportunity,because,you,may,cause,the,Eastern,Interconnection,to,become,unstable.
B),Pursue,this,opportunity,only,when,you,have,adequate,Dynamic,Reserves,on,your,system
C),Pursue,this,opportunity,as,quickly,as,possible
D),Pursue,this,opportunity,only,if,you,need,cranking,power,for,your,generating,unity,,ANS,-
,C),Pursue,this,opportunity,as,quickly,as,possible
Complete,(Total,System),Blackouts,are,characterized,by,which,of,the,following?
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b
pf2c
pf2d
pf2e
pf2f
pf30
pf31
pf32
pf33
pf34
pf35
pf36
pf37
pf38
pf39
pf3a
pf3b
pf3c
pf3d
pf3e

Partial preview of the text

Download PJM Generation Dispatch Exam Flashcards with Solutions and more Exams Project Management in PDF only on Docsity!

PJM GENERATION DISPATCH EXAM FLASH

CARDS QUESTIONS WITH 100% COMPLETE

SOLUTIONS.

Which,of,the,following,statements,is,correct,concerning,PJM,assuming,frequency,control,of,the,restorati on,process? A),PJM,assumes,control,once,an,external,transmission,tie,has,been,established. B),Once,an,Area,Control,Error,can,be,calculated,,PJM,will,assume,control. C),Whenever,it,becomes,too,much,of,a,burden,for,any,one,Transmission,Owner,within,the,RTO D),Whenever,the,Transmission,Owners,within,the,RTO,agree,to,let,PJM,control,the,process.,,ANS,- ,C),Whenever,it,becomes,too,much,of,a,burden,for,any,one,Transmission,Owner,within,the,RTO During,black,start,restoration,,priority,access,to,cranking,power,should,be,given,to: A),Hot,units,that,can,return,to,service,immediately. B),Combustion,turbines,in,areas,where,the,initial,disturbance,occurred C)Units,with,black,start,capability D),Hydro,Units,,ANS,-,A),Hot,units,that,can,return,to,service,immediately. During,a,restoration,,if,you,are,presented,with,the,opportunity,to,re- connect,with,the,Eastern,Interconnection,,you,should: A)Not,pursue,this,opportunity,because,you,may,cause,the,Eastern,Interconnection,to,become,unstable. B),Pursue,this,opportunity,only,when,you,have,adequate,Dynamic,Reserves,on,your,system C),Pursue,this,opportunity,as,quickly,as,possible D),Pursue,this,opportunity,only,if,you,need,cranking,power,for,your,generating,unity,,ANS,- ,C),Pursue,this,opportunity,as,quickly,as,possible Complete,(Total,System),Blackouts,are,characterized,by,which,of,the,following?

1 ,-,Most,common,type,of,blackout 2 ,-,May,require,coordinating,multiple,islands 3 ,-,Likely,to,result,in,Transmission,overloads,or,other,issues 4 ,-,Affects,a,very,large,geographical,area,,and,many,customers 5 ,-,Most,commonly,caused,by,human,or,switching,errors A), 1 ,&, 3 B), 2 ,&, 4 C), 3 ,&, 5 D), 1 ,,ANS,-,B), 2 ,&, 4 The,first,step,in,a,system,restoration,would,be,to: A),Immediately,notify,the,media,of,the,event B),Restore,as,much,of,the,area,load,as,possible C),Restore,as,much,under-frequency,load,as,possible D),Verify,that,communication,is,functional,with,your,neighbors,,ANS,- ,D),Verify,that,communication,is,functional,with,your,neighbors Why,would,an,offsite,power,to,generating,facilities,be,a,priority,during,the,restoration,process? A),To,provide,safe,shutdown,power,for,the,units B),To,meet,FERC,requirements C),To,provide,adequate,lighting,for,the,plant,operators,to,attempt,a,restart D),To,prepare,and,expedite,the,return,of,the,unit,,ANS,- ,D),To,prepare,and,expedite,the,return,of,the,unit Factors,that,help,determine,the,sequence,of,restoration,of,off-line,generation,include,(Pick,2):

C),1,, 3 ,and, 4 D),2,, 3 ,and, 4 ,,ANS,-,B),1,, 2 ,and, 4 During,system,restoration,,the,two,categories,of,reserves,are: A),dynamic,and,secondary B),spinning,and,quick,start C),dynamic,and,spinning D),spinning,and,primary,,ANS,-,C),dynamic,and,spinning During,a,system,restoration,you,have,400MW,of,Steam,capacity,,350MW,of,CT,capacity,and,300MW,of, Hydro,capacity,restored.,Your,largest,contingency,is,a,200MW,Steam,Unit.,You,have,also,restored,150M W,of,under-frequency,load.,What,is,your,total,dynamic,reserve?,(Load,pick- up,factors,are,5%,for,steam,,15%,for,hydro,and,25%,for,CT) A),142.5MW B),152.5MW C),285MW D),292.5MW,,ANS,-,C),285MW What,is,the,most,critical,communication,path,when,restoring,large,load,blocks,early,in,a,system,restorat ion? A),Between,the,Generating,Unit,and,the,Transmission,Owner B),Between,PJM,and,the,generating,plant C),Between,the,Generator,Owner,(or,MOC),and,the,generating,unit D),Between,the,transmission,owner,and,the,MOC,,ANS,- ,A),Between,the,Generating,Unit,and,the,Transmission,Owner

Your,entire,system,has,blacked,out,due,to,an,event.,You,receive,word,from,PJM,that,the,entire,region,is ,affected,as,well.,Your,blackstart,generation,resources,are,spread,throughout,your,system,,which,cover, a,large,area.,Which,restoration,strategy,would,be,the,best,for,you,to,implement? A),Combination,approach B),Bottom-up,Core,Island,approach C),Top-down,approach D),Bottom-up,Multiple,Island,approach,,ANS,-,D),Bottom-up,multiple,island,approach During,a,system,restoration,,which,entity,directs,the,loading,of,generation,,to,match,the,load,restored? A),PJM B),The,Generating,Unit C),The,Transmission,Owner D),The,Generation,Owner,(or,MOC),,ANS,-,C),The,Transmission,Owner Your,entire,system,has,blacked,out,due,to,an,event.,You,receive,information,the,your,neighboring,syste ms,are,also,blacked,out.,Your,main,urban,load,center,restoration,strategy,would,be,the,best,for,you,to,i mplement? A),Combination,approach B),Bottom-up,Core,Island,approach C),Top-down,approach D),Bottom-up,Multiple,Island,approach,,ANS,-,B),Bottom-up,Core,Island,approach Select,the,statement,that,best,describes,why,Minimum,Source,Requirements,have,been,established: A),To,ensure,system,stability,prior,to,interconnecting,with,another,entity B),To,reduce,major,frequency,fluctuations,when,energizing,load C),To,prevent,or,reduce,the,effects,of,line,changing,when,energizing,EHV,transmission

  • ,Have,the,ability,to,maintain,frequency,and,voltage,under,varying,load
  • ,Must,be,tested,every, 3 ,years
  • ,Must,be,able,to,run,for, 12 ,hours,,or,defined,by,the,TO,restoration,plan,,ANS,-,- Must,have,and,maintain,procedures,for,the,unit
  • Have,the,ability,to,maintain,frequency,and,voltage,under,varying,load
  • ,Must,be,tested,every, 3 ,years Which,of,the,following,statements,would,be,considered,an,implication,from,receiving,power,from,an,ou tside,entity? A),Equipment,Damage B),Isolation,of,the,unit,from,the,outside,entity C),Maximize,the,time,for,generator,restarts D),Unintentional,interconnection,between,the,two,areas,,ANS,- ,D),Unintentional,interconnection,between,the,two,areas Which,of,the,following,would,be,considered,pre- tie,preparations,when,interconnecting,islands?,(Select,2)
  • ,Ensure,reliable,communications,are,available,for,all,entities,involved,in,the,interconnection,process
  • ,Recalculation,of,reserves
  • ,Identification,of,the,transmission,line,to,tie,areas,together
  • ,Provide,updated,hydroelectric,capability,,ANS,-,- ,Ensure,reliable,communications,are,available,for,all,entities,involved,in,the,interconnection,process
  • ,Identification,of,the,transmission,line,to,tie,areas,together If,a,change,in,the,capability,of,a,Black,Start,resource,affects,the,ability,of,a,generator,to,meet,the,Trans mission,Operator's,individual,restoration,plant,,the,Generation,Operator,shall,notify,the,Transmission,O perator,of,the,known,changes,within. A), 4 ,hours

B), 8 ,hours C), 16 ,hours D), 24 ,hours,,ANS,-,D), 24 ,hours During,a,restoration,process,,Generation,Owners,are,required,to,update,their,progress,by,submitting,a,r eport: A),On,an,hourly,basis B),Every,1/2,hour C),For,every,unit,returning,to,service D),As,conditions,on,the,system,change,,ANS,-,A),On,an,hourly,basis Concerning,PJM,requirements,for,critical,start,generation,,which,of,the,following,statements,applies,to,t he,units,capability,to,maintain,frequency?,() A),Dynamic,offline,testing,of,the,units,voltage,controls B),Picking,up,an,isolated,block,of,loads C),Producing,leading,and,lagging,VARs D),Dynamic,Off-line,testing,of,the,units,governor,control,,ANS,-,B),Picking,up,an,isolated,block,of,loads D),Dynamic,Off-line,testing,of,the,units,governor,control During,system,restoration,,a,generator,should,not,be,loaded,above,the,level,of,available A),operating,reserve B),synchronized,reserve C),primary,reserve D),dynamic,reserve,,ANS,-,D),dynamic,reserve Dynamic,Reserves,consist,of

D),PJM,,ANS,-,B),The,Transmission,Owner While,progressing,through,your,system,restoration,plan,,you,come,across,a,transmission,line,that,has,b oth,of,its,breakers,closed.,The,line,is,far,removed,from,any,generation,sources.,Which,of,the,following,st atements,describes,the,best,course,of,action,you,should,take? A),The,line,is,clearly,faulted,and,should,not,be,re-energized,until,all,other,facilities,are,in,service. B),The,line,is,not,faulted,and,can,be,re-energized,immediately. C),Clear,the,remaining,breakers,on,the,bus,and,test,energize,it,with,a,remote,line D),Have,field,personnel,check,the,relay,targets,at,both,terminals,to,determine,if,the,line,is,faulted,,ANS,- ,D),Have,field,personnel,check,the,relay,targets,at,both,terminals,to,determine,if,the,line,is,faulted Using,the,following,information,,determine,the,maximum,amount,of,load,that,should,be,restored,(assu me,a,5%,governor,droop). Generation,Capacity,on-line,=,1000MW System,Load,=,800MW System,Frequency,=,60.5,Hz A),50MW B),90MW C),120MW D),150MW,,ANS,-,A),50MW Do,not,restore,load,blocks,that,exceed,5%,of,the,synchronized,gen,capacity Which,of,the,following,would,be,considered,as,the,'final,step',in,determining,the,status,of,generation,af ter,a,disturbance,or,event,has,occurred? A),Determine,the,status,of,generation,that,was,off-line,prior,to,the,event

B),Stabilize,surviving,on-line,generation C),Determine,what,generation,survived,the,event,and,is,still,in,service D),Determine,the,status,of,generation,that,was,off-line,prior,to,the,event,,ANS,- ,C),Determine,what,generation,survived,the,event,and,is,still,in,service According,to,PJM,,how,many,critical,Blackstart,Unit,outages,may,there,be,per,station? A), 3 B), 2 C), 4 D), 1 ,,ANS,-,D), 1 2,are,allowed,per,zone,but,must,be,at,different,stations Which,of,the,following,are,considered,as,'critical,load',by,PJM? A)Two,independent,feeds,into,each,nuclear,facility,for,station,start-up B),Power,to,pumping,plants,for,underground,cables C),Gas,infrastructure,equipment D),Light,and,power,to,critical,substations,,ANS,-,C),Gas,infrastructure,equipment During,system,restoration,operations,,a,member,company,has,a,steam,capacity,of,600MW,,combustion, turbine,capacity,of,200MW,and,100MW,of,hydro,capacity.,The,load,factors,(governor,response),are,5%, ,25%,,and,15%,respectively.,Also,,50MW,of,load,with,underfrequency,load,shedding,enabled,has,been,r estored.,What,is,the,total,governor,reserve,capability,of,the,company's,steam,,combustion,turbine,and, hydro,units?,,ANS,-,95MW During,system,restoration,prior,to,synchronization,of,a,unit,,the,dispatcher,should,ensure,sufficient,load ,is,available,to A),economize,unit,operation

,the,capability,of,each,generation,resource,to,meet,the,restoration,plan,requirements.,Under,this,proce ss,,each,generator,shall,be,tested,at,least,every A),Year B),Three,years C),Five,years D),Seven,years,,ANS,-,B),Three,years When,connecting,islands,,how,do,you,know,if,your,system,is,stable?,(Pick,2)

  • ,The,overall,inertia,of,the,generators,will,be,decreased,when,interconnected
  • ,Small,deviations,in,frequency,and,voltage,when,restoring,load
  • ,Load,is,being,picked,up,with,automatic,under-frequency,relaying,available
  • ,Adequate,operating,reserves,,ANS,-,-,Small,deviations,in,frequency,and,voltage,when,restoring,load
  • ,Load,is,being,picked,up,with,automatic,under-frequency,relaying,available Which,of,the,following,can,NOT,be,changed,hourly?
  • ,Regulation,high,and,low,limits
  • ,MW,capability,of,regulation
  • ,price,of,regulation
  • ,status,of,regulation,,ANS,-,-,price,of,regulation The,field,windings,of,a,generator,are,located,in,which,part,of,the,generator?
  • ,Stator
  • ,Turbine
  • ,Rotor
  • ,Exciter,,ANS,-,-,Rotor

Which,of,the,following,is,not,a,goal,of,the,PJM,Market,Monitor?

  • ,Maximization,of,generator,revenues
  • ,Limit,returns,to,market,power
  • ,Provide,incentives,to,competitive,behavior
  • ,Facilitate,competition,,ANS,-,-,Maximization,of,generator,revenues A,means,of,generating,hot,water,,and/or,high,and,low,pressure,steam,and,electricity,at,the,same,time,,f rom,the,same,energy,source,,yielding,a,highly,efficient,power,plant,is,defined,as: A),Combined,cycle B),Combustion,turbine C),Simple,cycle D),Co-generation,,ANS,-,D),Co-generation The,basic,function,of,Gen,Checkout,is,to:
  • ,compare,the,values,in,eMkt,to,the,outages,in,eDART
  • ,offer,units,into,the,Day,Ahead,Market
  • ,Compare,the,historical,generator,outage,values,in,eGADS,to,the,outages,in,eDART
  • ,compare,the,values,in,eMkt,to,the,pending,OASIS,transmission,reservations,,ANS,-,- ,compare,the,values,in,eMkt,to,the,outages,in,eDART Which,of,the,following,reserves,is,not,part,of,the,IRC,(Instantaneous,Reserve,Check)? A),Dynamic B),Spinning C),Operating

Operating,Reserves,,ANS,-,T,<=,30min Primary,+,Secondary Offline,+,Online Offline,=,lesser,of:,spin,max,,spin,ramp,rate,(30min,-,TTS) Online,=lesser,of:,ramp,rate,*, 30 ,min,,spin,max,-,current,MW,level Supplemental,Reserves,,ANS,-,=,operating,reserve,-,primary,reserve primary,reserve,=,synchronized,+,quick,start Reliability,Analysis When,does,it,happen? What,is,the,rebid,period?,,ANS,-,Second,commitment,to,ensure,that,their,is,enough,gen,to,meet,real- time,load,forecast Schedule: 1600 ,-,Day,ahead,results,posted 1600 - 1800 ,- ,Rebid,period,(Gives,units,not,picked,up,in,the,day,ahead,an,opportunity,to,change,offers/parameters) 1800 ,-,Reliability,analysis What,is,the,difference,between,Dynamic,Reserve,and,Synchronized,Reserve?,,ANS,-,Dynamic,Reserve,- ,(automatic),reserve,on,generators,that,is,available,via,governor,action,and,load,w/,under,frequency,rel aying Synchronized,Reserve,-,(manual),spinning,online,gen What,are,the,two,types,of,reserves,monitored,during,a,restoration?,,ANS,- ,Synchronous,and,Dynamic,reserves

Which,of,the,following,equipment,controls,generator,shaft,speed,,controls,frequency,,and,adjusts,gener ation,for,small,changes,in,load? A),Output,terminal,voltage,of,the,generator B),Governor C),Automatic,Voltage,Regulator,(AVR) D),Exciter,,ANS,-,B),Governor A,500MW,generator,is,following,economic,dispatch,and,is,currently,loaded,at,400MW.,This,units,ramp,r ate,is,3MW/min.,How,much,Spinning,Reserve,is,available,on,the,unit? A),10MW,Tier,1,,90MW,Tier, 2 B),30MW,Tier,1,,70MW,Tier, 2 C),0MW,Tier,1,,100MW,Tier, 2 D),30MW,Tier,1,,0MW,Tier, 2 ,,ANS,-,D),30MW,Tier,1,,0MW,Tier, 2 What,is,the,deadline,for,a,self-scheduling,unit,for,spinning,reserve? A), 1800 ,on,the,day,before B), 120 ,minutes,before,the,operation,hour C), 60 ,minutes,before,the,operation,hour D), 20 ,minutes,before,the,operation,hour,,ANS,-,C), 60 ,minutes,before,the,operation,hour To,whom,does,the,Market,Monitor,Report? A),The,largest,PJM,member B),NERC C),Organization,of,PJM,Inc,(OPSI) D),PJM,Board,of,Members,,ANS,-,D),PJM,Board,of,Members

When,is,an,IRC,requested?,What,types,of,reserves,does,it,request?,,ANS,- ,An,IRC,is,typically,requested, 30 - 45 ,min,prior,to,a,peak.,Types,of,reserves,on,the,check:

  • operating,reserve
  • synchronized,reserve
  • quick,start,(hydro/other)
  • supplemental Regarding,abuses,to,market,rules,,what,entity,holds,the,authority,for,enforcement? A),The,PJM,Market,Monitor B),The,PJM,Members,Committee C),NERC D),FERC,,ANS,-,FERC Under,excited,test,results,means,the,system,is?,,ANS,-,Leading,(absorbing,VARs) What,type,of,units,are,required,to,conduct,Generator,Reactive,Testing,and,how,often?,,ANS,-,Units:
  • Any,unit,20MW,and,up
  • Aggregate,units,75MW,and,up
  • All,black,start,units
  • Synchronized,condenser,units,greater,than,20MW, Frequency:
  • every, 5 ,years What,is,the,difference,between,Tier, 1 ,and,Tier, 2 ,synchronized,reserves?,,ANS,-,Tier, 1 ,(economic),- ,Online,units,that,follow,economic,dispatch,and,only,partially,loaded,and,therefore,are,able,to,increase, output,within, 10 ,minutes,following,PJM,dispatcher,request,to,event Tier, 2 ,(non-economic),-,Resources,that,offered,into,the,synchronized,reserve,market,and,cleared
  • condensers,(CTs,and,Hydro),transition,to,online,tier, 2 ,condense,mode
  • steam,reduced,to,provide,tier, 2 ,support
  • CTs,online,at,min-operating,at,a,point,that,deviates,from,econ
  • Demand,response,that,can,drop,load What,is,Regulation?,,ANS,-,Regulation,is:
  • ,A,variable,amount,of,generation,under,automatic,control
  • ,Independent,of,economic,cost,signal
  • ,obtainable,within, 5 ,minutes
  • ,Responds,to,frequency,deviations The,purpose,of,the,Heavy,Load,Voltage,Schedule,action,is,to,increase,reactive,reserves,on: A),All,SVCs B),The,EHV,system C),All,synchronized,generating,units D),The,distribution,system,,ANS,-,B),The,EHV,system What,is,the,temperature,trigger,for,a,Cold,weather,alert,in,a,control,zone? A),- 5 ,Degrees B), 0 ,Degrees C), 10 ,Degrees D), 32 ,Degrees,,ANS,-,C), 10 ,Degrees What,product,does,PJM,schedule,to,protect,the,system,against,unexpected,generation,loss? A),Regulations B),Emergency,procedures