A series of multiple-choice questions and answers related to backflow prevention practices in plumbing systems. It covers various aspects of backflow prevention, including the types of backflow preventers, their installation, testing, and maintenance. Useful for individuals studying plumbing or related fields, as it provides a practical assessment of their understanding of backflow prevention principles.
Typology: Exams
1 / 17
This page cannot be seen from the preview
Don't miss anything!










Containing a plumbing system from the public water supply requires backflow protection at the _______? A. Appliance or fixture B. Building foundation C. Irrigation system D. Service Connection E. Sprinkler riser - Answers :Service Connection Backflow preventer manufacturers recommend that assemblies be field-tested annually and when_____? A. Installed B. Moved C. Repaired or Installed D. Shut down E. Water suppliers provide notice - Answers :Repaired or Installed A differential pressure gauge reading of 0.2 psid is represented on water column sight tube by _____? A. 1/16 in. (0.16 cm) B. 1/2 in. (1.3 cm) C. 2 in. (5.1 cm) D. 3.5 in. (8.9 cm) E. 5.5 in. (14 cm) - Answers :5.5 in. (14 cm) Pollution of a public water supply suggests the substance in the water is ____? A. Aesthetically bad B. Biological with virus only C. Lowering the pH below 1. D. Radiological E. Toxic - Answers :Aesthetically bad Atmospheric vacuum breakers will typically be located on ____? A. Commercial irrigation systems B. Fire-suppression systems C. Plumbing fixtures or appliances D. Utility storage tanks E. Water service connections - Answers :Plumbing fixtures or appliances The mechanical component of an atmospheric vacuum breaker serves as an air-inlet valve and a ____? A. Check valve B. Regulating valve
C. Relief valve D. Shut-off valve E. Test port - Answers :Check valve A deck-mounted atmospheric vacuum breaker's critical installation level is above the outlet usage by ___? A. 1 in. (2.5 cm) B. 3 in. (7.6 cm) C. 6 in. (15 cm) D. 12 in. (30 cm) E. 18 in. (46 cm) - Answers :1 in. (2.5 cm) A hose-bibb connection is required to have a permanently installed ____? A. Atmospheric vacuum breaker B. Backflow preventer C. Pressure vacuum breaker D. Shut-off valve E. Spill-resistant vacuum breaker - Answers :Atmospheric vacuum breaker Atmospheric vacuum breakers must not be subject to continuous water pressure for more than ___ hr. A. 3 B. 6 C. 12 D. 18 E. 24 - Answers : A submerged atmospheric vacuum breaker may be considered a(n) _____? A. Backflow preventer B. Cross-connection C. Expensive elbow D. Typical installation E. Useful training photo - Answers :. Cross-connection Flow from the outlet of an atmospheric vacuum breaker must not reach a _____? A. Closed tank B. Section of straight tubing C. Submerged inlet D. Toxic substance E. Valve - Answers :Valve An atmospheric vacuum breaker is not required to have a(n) _____? A. Annual field test B. Installation elevation C. Installation inspection D. Label
E. Toxin monitoring - Answers :Appliance protection A direct cross-connection suggests the piping system may be subjected to ____? A. Backpressure or backsiphonage B. Backsiphonage only C. Periodic inspection D. Sustained pressure E. Toxic materials - Answers :Backpressure or backsiphonage A pipe restriction's flow velocity increase may allow ____? A. Aspiration B. Backpressure C. Low turbulence D. Pressure head E. Pressure surges - Answers :Aspiration Water supply contamination from backflow may result in ____? A. A bad taste B. Coloration C. Death D. Odor or smell E. Pipe wall mineral deposit flaking - Answers :Death To prevent backflow, an atmospheric vacuum breaker is primarily designed to ____? A. Allow air into the outlet piping system B. Create an elevation loop above ground C. Introduce head loss D. Prevent backpressure E. Restrict velocity - Answers :Allow air into the outlet piping system If not marked, a pressure vacuum breaker's critical level is ____? A. At the bottom of the valve body B. Measured from the check valve inlet C. Measured from the body outlet D. Not important E. The air-inlet valve opening - Answers :At the bottom of the valve body A pressure vacuum breaker may have ____ on the assembly's discharge piping. A. Auxiliary water supply looped irrigation B. A boiler C. A booster pump D. Elevated piping E. Irrigation sprinkler heads - Answers :Irrigation sprinkler heads The minimum loading to open a pressure vacuum breaker's air-inlet valve is ____? A. 1 psi (6.89 kPa)
B. 2 psi (13.8 kPa) C. 3 psi (20.7 kPa) D. 4 psi (27.6 kPa) E. 5psi (34.5 kPa) - Answers :1 psi (6.89 kPa) The recorded value of a pressure vacuum breaker check valve is determined when ____? A. Both shut-off valves are closed B. The high-bleed valve is opened C. The air-inlet valve opens D. Water stops flowing from test cock 1 E. Water stops flowing from test cock 2 - Answers :Water stops flowing from test cock 2 Pressure vacuum breaker shut-off valves must be _____ valves. A. Angle B. Gate C. Globe D. Regulating E. Tightly closed - Answers :Tightly closed An indication that a pressure vacuum breaker is undersized for its application is _____? A. Air-inlet valve leakage B. Bonnet distortion C. Chatter or noise during flow D. Disc pitting E. Spring elongation - Answers :Chatter or noise during flow Continuous flow from a pressure vacuum breaker's test cock 2 with shut-off valve 2 open and shut-off valve 1 closed is an indication of _____? A. Backpressure backflow B. Backsiphonage backflow C. A failed air-inlet valve D. A leaking check valve E. A leaking or damaged shut-off valve 1 - Answers :Backpressure backflow Pressure vacuum breakers may be used on the following applications except ____? A. High hazard/backsiphonage B. High hazard/continuous pressure C. Low hazard/backpressure D. Low hazard/backsiphonage E. Low hazard/intermittent pressure - Answers :Low hazard/backpressure A double check valve assembly is installed 12 in. (30.5 cm) above the floor for _____? A. Electrical code compliance B. Floor draining C. Maintenance
Prior to testing the check valves in the direction of flow on a double check valve assembly using a high and low side on the gauge, a tester must first ____? A. Determine the tightness of shut-off valve number 2 B. Notify the owner of the water shut-off C. Record the water supply line pressure D. Submit the test report to the water supply E. Test check valve number 2 with backpressure - Answers :Determine the tightness of shut-off valve number 2 A double check valve assembly installed in a vertical flow down orientation is only allowed ______? A. In a basement or vault B. If the assembly was tested and approved as such C. If the check weight does not compress the spring D. On fire-suppression systems E. On water supply service connections - Answers :If the assembly was tested and approved as such A check valve field test reported value of 0.8 psid (5.5 kPa) suggests _____? A. A passing check valve B. A broken or failed spring C. Debris in the check seat D. Disc softening or decay E. Low water pressure - Answers :Disc softening or decay A reduced pressure principle assembly's relief valve is loaded to _____? A. Push the valve away from its seat B. Push the valve on to its seat C. Remain closed with any zone pressure D. Remain open with any supply pressure E. Sustain all water hammer conditions - Answers :Push the valve away from its seat The purpose of the reduced pressure principle assembly check valve number 1 loading is to _____? A. Create a pressure head increase B. Create a reduction in water pressure C. Provide water pressure to the relief valve diaphragm D. Reduce system pressure to the plumbing code limit E. Sustain the assembly's buffer - Answers :Create a reduction in water pressure Intermittent relief valve discharge from a reduced pressure principle assembly is probably caused by _____? A. A fouled check valve number 1 B. A fouled check valve number 2 C. A fouled relief valve
D. A partially closed shut-off valve number 2 E. Water hammer or hydraulic shock - Answers :Water hammer or hydraulic shock Backpressure to a reduced pressure principle assembly fouled check valve number 2 will likely _____? A. Dissipate through the air-vent B. Force the relief valve to open and discharge C. Have no visible effect D. Push the check valve closed E. Remain in the system - Answers :Force the relief valve to open and discharge An air-gap separation must be maintained at a reduced pressure principle assembly's _____? A. Build drain B. Domestic Supply C. Indirect drain outlet D. Relief valve discharge E. Stationary sensor - Answers :Relief valve discharge A reduced pressure principle assembly's buffer can be described as a ____? A. Soft-seated check upstream of the assembly B. Difference between the values for check valve 1 and check valve 2 C. Difference between the check valve 1 loading and the relief valve opening point D. Difference between the relief valve opening point and check valve 2 E. Sum of the check valve 1 loading and the relief valve divided by 2 - Answers :Difference between the check valve 1 loading and the relief valve opening point When a reduced pressure principle assembly is installed vertically, the relief valve discharge must be _____? A. To a floor drain 2 times the piping size B. Higher than check valve number 1 C. Lower than check valve number 1 D. Lower than check valve number 2 E. Piped with the flow directed down - Answers :Lower than check valve number 1 The maximum protection provided by a reduced pressure principle assembly is ____? A. High hazard/backpressure B. High hazard/backsiphonage C. High hazard/backpressure or backsiphonage D. Low hazard/backpressure E. Low hazard/backpressure or backsiphonage - Answers :High hazard/backpressure or backsiphonage The reduced pressure principle assembly's number 2 check valve is loaded to close the valve with a minimum differential pressure of _____? A. 1 psid (6.9 kPa)
C. 1.5 in. (3.8 cm) D. 2.0 in. (5.1 cm) E. 3.0 in. (7.6 cm) - Answers :1.0 in. (2.5 cm) Water discharged through an air gap to an open tank surface has a pressure of ____? A. 0 psi absolute B. 0 psi atmospheric C. 0 psi gauge D. Static line pressure E. Vapor pressure - Answers :0 psi atmospheric Air-gap separations must be ____? A. Classified B. Inspected annually C. Laboratory listed D. Tested and repaired E. Tested with a sight tube - Answers :Inspected annually When close to two intersecting walls, an air-gap separation is increased from 2 diameters to _____ diameters. A. 2. B. 3 C. 3. D. 4 E. 4.5 - Answers : An air-gap separation is mandatory between the potable supply and a(n) _____? A. Bakery dough mixer B. Isolation assembly C. Pressure washer D. Sanitary sewer E. Water meter - Answers :Sanitary sewer Toxins may enter a water supply pipe air-gap separation through the ____? A. Atmosphere B. Control valve C. Pressure tank D. Receiving vessel E. Sanitary sewer - Answers :Atmosphere A properly installed barometric loop will prevent _____? A. Backpressure B. Backsiphonage C. Freezing D. Leakage E. Surges - Answers :Backsiphonage
A swing connection is a type of _____? A. Backflow preventer B. Cross-connection C. Detector assembly D. Gauge component E. Shut-off valve repair tool - Answers :Cross-connection A barometric loop must be installed 35 ft (10.7 m) above the highest ____? A. Boiler B. Fixture outlet C. Gate valve D. Service connection E. Water meter - Answers :Fixture outlet A spool is used to connect a ____? A. Copper and ductile iron pipe B. Copper and PVC pipe C. Disc retainer and valve guide D. Potable and non-potable system E. Test cock - Answers :Potable and non-potable system A fire sprinkler system's backflow protection for a black-iron pipe system is typically ____? A. An air-gap separation B. A double check valve assembly C. A reduced pressure principle assembly D. A reduced pressure detector assembly E. No protection required - Answers :A double check valve assembly The dual check with an intermediate vent is used primarily for ____? A. Commercial boilers B. Industrial process water piping C. Hose bibbs D. Low-pressure residential boilers E. Swimming pool chlorinators - Answers :Low-pressure residential boilers A hose connection vacuum breaker's maintenance includes _____? A. Check disc replacement B. Diaphragm replacement C. Draining for winterization D. Replacement every 2 years E. Water flushing - Answers :Draining for winterization Pressure loss per foot of elevation rise is ____? A. 0.43 psi (2.99 kPa)
C. Double check valve assembly D. Pressure vacuum breaker assembly E. Reduced pressure principle assembly - Answers :Reduced pressure principle assembly While obtaining a reduced pressure principle assembly's relief valve opening point using a high and low-pressure hose, turning the gauge valve more than 1/4 turn indicates a leaking _____? A. Check valve B. Gauge Valve C. Relief valve D. Shut-off valve E. Test cock - Answers :Shut-off valve A reduced pressure principle assembly check valve number 1 is field-tested _____? A. In the direction of flow only B. Under backpressure C. Under backsiphonage D. Under backpressure and the direction of flow E. Under backpressure and backsiphonage - Answers :In the direction of flow only A thrust block is designed to ____? A. Adjust pressure changes B. Maintain pipe joint integrity C. Stop backflow D. Stop water hammer E. Support failing soil conditions - Answers :Maintain pipe joint integrity Water hauling truck fill stations should have either an air-gap separation or a(n) _____? A. Atmospheric vacuum breaker B. Double check valve assembly C. Dual check valve D. Pressure vacuum breaker assembly E. Reduced pressure principle assembly - Answers :Reduced pressure principle assembly When testing a reduced pressure principle assembly using three hoses, a difference between the apparent and actual reading is likely due to _____? A. Backflow B. Check valve failure C. Disc compression D. A leaking shut-off valve E. Opening of the bypass control valve - Answers :A leaking shut-off valve The plumbing code requires that a spill-resistant vacuum breaker be installed above the highest use by at least _____?
A. 3 in. (7.6 cm) B. 6 in. (15 cm) C. 9 in. (23 cm) D. 12 in (30 cm) E. 18 in. (46 cm) - Answers :12 in (30 cm) Modifications of any kind to a backflow preventer will _____? A. Alter its head loss B. Render it inoperable C. Require a tester failure D. Validate its warranty E. Void its approval - Answers :Void its approval A water system pressure of 10 psi (69 kPa) and a plumbing system pressure of 20 psi (138 kPa) may be described as _____? A. Backpressure B. Backsiphonage C. Gauge pressure differential D. inflow/infiltration E. Static condition - Answers :Backpressure According to ANSI standard, potable water pipe marking requirements are _____ lettering. A. Blue background with white B. Green background with white C. Green background with yellow D. White background with blue E. White background with green - Answers :Green background with white A water closet ball cock must be installed above the opening of the overflow pipe by at least _____? A. 1.0 in. (2.5 cm) B. 1.5 in. (3.8 cm) C. 2.0 in. (5.1 cm) D. 2.5 in. (6.4 cm) E. 3.0 in. (7.6 cm) - Answers :1.0 in. (2.5 cm) Gauges used for field tests of backflow preventers must have the calibration checked ____? A. After every 50 tests B. Annually C. If dropped D. If used in temperature extremes E. With water - Answers :Annually New backflow prevention assemblies should be tested ____?
A. Clean dirt and possible corrosion buildup B. Create a water flow condition C. Purge air from the assembly D. Reduce pressure differentials E. Verify water pressure - Answers :Clean dirt and possible corrosion buildup If testing a backflow preventer using a differential gauge and a single hose, it is important to ____? A. Keep the high and low manifold valves open B. Maintain the gauge and hose connections at the same height as the assembly C. Open the high-pressure bleed valve before opening a test cock D. Open the low-pressure and bypass control valves E. Plug the bypass and low-pressure hose end connections - Answers :Maintain the gauge and hose connections at the same height as the assembly When testing a backflow preventer, shut-off valve 2 is closed before shut-off valve 1 because _____? A. Failures in outlet valves are determined first B. It slows the rate of flow through the assembly C. The potential of backflow during the test is eliminated D. Venturi flow through the check will cavitate the assembly E. Water pressure will be maintained for testing - Answers :Water pressure will be maintained for testing Plumbing codes define hot water as above _____? A. 100 degrees F (38 degrees C) B. 110 degrees F (43 degrees C) C. 140 degrees F (60 degrees C) D. 180 degrees F (82 degrees C) E. 210 degrees F (99 degrees C) - Answers :110 degrees F (43 degrees C) Before the physical test of a backflow preventer may begin, the tester must first _____? A. Begin completing the test report form B. Conduct a downstream plumbing hazard inspection C. Obtain a repair kit D. Obtain permission to shut-down the water service E. Provide notice to the fire department - Answers :Obtain permission to shut-down the water service If pressure vacuum breaker air-inlet valve does not open and the gauge indicator does not drop, a reason may be _____? A. A leaking shut-off valve 2 with a parallel installation B. A tightly closing shut-off valve number 1 C. The check valve is failed D. The high-pressure bleed valve is open E. The test cock is open - Answers :A leaking shut-off valve 2 with a parallel installation
A backflow preventer creates a closed plumbing system that requires the installation of a(n) _____? A. Expansion tank B. Globe valve C. Pressure reducing valve D. Temperature and pressure relief valve E. Utility box key - Answers :Expansion tank When both shut-off valves are closed on a reduced pressure principle assembly and test cock 2 is opened, a tester should expect _____? A. Check valve number 1 to open B. Continuous flow from the test cock C. No flow from the test cock D. No result E. Relief valve discharge - Answers :Relief valve discharge The force needed to close a check valve in a dual check is _____? A. 1 psid (6.9 kPa) B. 2 psid (13.9 kPa) C. 3 psid (20.7 kPa) D. 4 psid (27.6 kPa) E. 5 psid (34.5 kPa) - Answers :1 psid (6.9 kPa)