A comprehensive set of multiple-choice questions and answers related to backflow prevention. it covers various types of backflow preventers, testing procedures, and crucial safety measures. The detailed explanations accompanying each answer enhance understanding and retention of key concepts in plumbing and water safety.

Typology: Exams

2024/2025

Available from 04/21/2025

may-blessed
may-blessed 🇺🇸

4.1

(8)

31K documents

1 / 4

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Backflow Test #1 - Questions With Fully Explained
Solutions
Which type of backflow preventer is most reliable Correct Answer -
Air gap
What is the maximum pressure drop a little through a double check
now assembly Correct Answer - 10 psi
To break the back-siphonage action the best approach is Correct
Answer - Introduce air into the system
The maximum height that water can be drawn above a free water
surface by back-siphoange is Correct Answer - 34 feet
Watermain pressure is drastically reduced to a reduce pressure
principal backflow preventer the relief valve should Correct Answer
- Always open to discharge the water in the zone
In approved Errgott must have at least __________of free air space
Correct Answer - A minimum of two pipe diameter of the supply
pipe or 6 inches which ever is lesser
What is the most important step before installing backflow prevention
assemblies in new or existing lines Correct Answer - Play planes
will be flushed all chips scale and foreign matter
A parallel side-by-side backflow prevention assembly installation as
desired in order to Correct Answer - Allow for testing and
maintenance
When testing an RP the relief of discharges at the number to shut off
valve is closed the problem is Correct Answer - A faulty number
one check valve
pf3
pf4

Partial preview of the text

Download Backflow Prevention: Multiple Choice Questions and Answers and more Exams Engineering in PDF only on Docsity!

Backflow Test #1 - Questions With Fully Explained

Solutions

Which type of backflow preventer is most reliable Correct Answer - Air gap What is the maximum pressure drop a little through a double check now assembly Correct Answer - 10 psi To break the back-siphonage action the best approach is Correct Answer - Introduce air into the system The maximum height that water can be drawn above a free water surface by back-siphoange is Correct Answer - 34 feet Watermain pressure is drastically reduced to a reduce pressure principal backflow preventer the relief valve should Correct Answer

  • Always open to discharge the water in the zone In approved Errgott must have at least __________of free air space Correct Answer - A minimum of two pipe diameter of the supply pipe or 6 inches which ever is lesser What is the most important step before installing backflow prevention assemblies in new or existing lines Correct Answer - Play planes will be flushed all chips scale and foreign matter A parallel side-by-side backflow prevention assembly installation as desired in order to Correct Answer - Allow for testing and maintenance When testing an RP the relief of discharges at the number to shut off valve is closed the problem is Correct Answer - A faulty number one check valve

What shut off's must be closed in order to test a double check valve assembly Correct Answer - Upstream valve When testing a pressure vacuum breaker the air inlet must open before the gauge falls to Correct Answer - 1 psi Before testing a reduced pressure backflow prevention is so were you notice red water discharging from the reef well you should first Correct Answer - Turn off the number one and number two shut off valves immediately Which of the following should not be utilized for protection against a back pressure backflow condition Correct Answer - Pressure vacuum breaker Test cock #1 On a double check valve assembly should be Correct Answer - Upstream supply side of shut off # He reduce pressure principal backflow preventer must be installed so that the relief of it is at least how far above the floor Correct Answer

  • 12inches What type of backflow prevention assembly should be installed on a customer side of the water meter and drawing b Correct Answer - RPZ And effective cross connection control program requires the complete cooperation of the following Correct Answer - Water purveyor health agency plumbing inspector plumber and the consumer When establishing a cross connection control program what information is not essential on your survey Correct Answer - How much water the customer uses

In assembly consisting of to check valves and I differential relief valve located between the two check valves is an Correct Answer - Reduce pressure principal assembly Unobstructive vertical distance through a free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank plumbing fixture or other device in the flood little room though the receptacle is Correct Answer - Air gap