CERTIFIED WILDFIRE MITIGATION SPECIALIST CWMS Test (Construction Edition) questions, Exams of Nursing 2025/2026 |Graded A+ |Guaranteed Pass CERTIFIED WILDFIRE MITIGATION SPECIALIST CWMS Test (Construction Edition) questions, Exams of Nursing 2025/2026 |Graded A+ |Guaranteed Pass
Typology: Exams
1 / 8
This page cannot be seen from the preview
Don't miss anything!





ASTM E2886 - ANSWER -Standard for testing ability of exterior vents to resist ember entry NFPA 1142 Standard for Water Supplies for Suburban and Rural Fire Fighting - ANSWER -At minimum every building shall be provided with a water supply meeting requirements of _______________________________.
or have a minimum 20 min fire rating - ANSWER -Exterior doors shall be 13 ft 6 inch vertical Unobstructed width of 20ft - ANSWER -Vertical clearance for roadways and unobstructed width heavy timber, ignition resistant material, fire-retardant treated wood, or have minimum 1 hour fire rated construction material (Unless AHJ declares risk warrants greater protection) - ANSWER - Exterior walls shall be heavy timber construction, non-combustible material, fire- retardant treated wood, other ignition resistant materials, or have a 1 hour fire rating - ANSWER -All projections (balconies, decks, etc) shall be of 5/8 inch sheathing or non-combustible materials - ANSWER - Eaves shall be boxed in with _______________________________________ or _________________________________________. NFPA 1144 Standard for reducing structure ignition hazards from wildland fire
6ft / 8ft - ANSWER -Signs shall be visible from the road and no less than __________ nor more than __________ above the surface of the road. 4inchs / 1/2 inch - ANSWER -On signs, all numbers and symbols shall be a minimum of ___________ in height with __________ stroke and shall be reflectorized and contrasting with background color of sign. 10% - ANSWER -Maximum driveway grade without mitigation measures agreed upon by fire department and developer/owner. Be provided with turnouts or turnarounds at locations approved by local fire authorities. - ANSWER -Where a driveway is greater than 300 ft it shall
__________. All buildings - ANSWER -Which building require means of access for emergency responders, egress/ingress and evacuations? 50ft / "Hammerhead T" Turnaround (For 3 Point Turns) - ANSWER -Every dead end fire service access road shall be provided with a turnaround at the terminus having a minimum of __________ or
_______________. Wildland Urban Intermix - ANSWER -Area where structures are scattered and intermingled with wildland fuels.
10 ft - ANSWER -Ideally canopies of mature trees will be no closer than __________ to the edge of the structure. 18 ft in ILA (0-30ft) 12 ft (30-60ft) 6 fit (60-100ft) No Recommendation (>100ft) - ANSWER -Canopy spacing in Intermediate Landscaped Area/Defensible Space 30-100/200 ft Structure Ignition Zone Boundaries per 1144 - ANSWER -1) Zone Generally extends to 200ft, but it is acknowledged that 100ft is sometimes enough 2)There is no mention of the 0-5 ft zone. "Intermediate Landscaped Area" refers to 0-30ft. 2 Basic Fuel Model Clasificaitons - ANSWER -1) National Forest Fire Laboratory (NFFL) Fire Behavior Fuels Models
Which standard/chapter? 12 ft / 13 1/2 ft - ANSWER -Where the driveway is greater than 150 ft in length it shall not be less than _________ in unobstructed width with ____________ vertical clearance. NFPA 1144 - Standard for reducing Structure Ignition Hazards in Wildland Fires - ANSWER -Which NFPA Standard outlines ways to reduce the risk of home/property loss during wildfires? NFPA 1140 - Standard for Wildland Fire Protection (Replaces NFPA 1051,1141, 1143, 1144) - ANSWER -New, Consolidated Standard (and which previous standards it replaces) 9 - ANSWER -Parking shall only be allowed where an additional ________ ft of road width is provided. Dead end roads in excess of 300ft shall be provided with turnouts and turnarounds. - ANSWER -Requirements for dead end roads. Require a noncombustible wall or barrier - ANSWER -The AHJ shall have the authority to _________________________________________________ where sufficient space is unavailable between structures and undisturbed native vegetation or slopes.
30 ft / the start of construction - ANSWER -Vegetation shall be modified to mitigate hazardous conditions with in _____________ of the foundations prior to __________________________________________________________. NFPA 256 - Standard methods of fire tests of roof coverings ASTM E 108 - Standard test methods for fire tests of roof coverings - ANSWER -Only listed roof coverings tested and rated in accordance with ________________________ and _____________________________ shall be used. (Specific class shall be consistent with hazard analysis completed prior to construction). 30 ft - ANSWER -Building closer than __________ to a vegetated slope shall require special mitigation measures as determined by the AHJ. 30 ft - ANSWER -Separation distance between primary and accessory structures on each lot and structure on adjacent lots shall not be less than __________.