CERTIFIED WILDFIRE MITIGATION SPECIALIST CWMS Test (Construction Edition) questions, Exams of Nursing

CERTIFIED WILDFIRE MITIGATION SPECIALIST CWMS Test (Construction Edition) questions with accurate detailed solutions

Typology: Exams

2025/2026

Available from 01/08/2026

smart-scores
smart-scores 🇺🇸

4.6

(5)

17K documents

1 / 7

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
CERTIFIED || WILDFIRE || MITIGATION || SPECIALIST ||
CWMS || Test || (Construction || Edition) || questions ||
with || accurate || detailed || solutions
ASTM || E2886 || - || correct || answer✔✔Standard || for || testing || ability || of || exterior || vents || to || resist || ember ||
entry
NFPA || 1142 || Standard || for || Water || Supplies || for || Suburban || and || Rural || Fire || Fighting || - || correct ||
answer✔✔At || minimum || every || building || shall || be || provided || with || a || water || supply || meeting ||
requirements || of || _______________________________.
1) || Education ||
2) || Engineering ||
3) || Enforcement || - || correct || answer✔✔Wildland || Fire || Mitigation || activities || fall || into || what || 3 || broad ||
categories?
10% || - || correct || answer✔✔Steepest || allowable || road || grade || (without || other || mitigation || measures || agreed
|| on || by || AHJ)
NFPA || 1143 || Standard || for || Wildland || Fire || Management || - || correct || answer✔✔Which || NFPA || standard ||
provides || minimum || requirements || to || fire || protection || organizations || on || the || management || of || wildland ||
fire, || including || prevention, || mitigation, || preparation || and || suppression?
Solid-core || wood || no || less || than || 1 || 3/4 || inch || thick
approved || non-combustible || material
or || have || a || minimum || 20 || min || fire || rating || - || correct || answer✔✔Exterior || doors || shall || be
13 || ft || 6 || inch || vertical
1
pf3
pf4
pf5

Partial preview of the text

Download CERTIFIED WILDFIRE MITIGATION SPECIALIST CWMS Test (Construction Edition) questions and more Exams Nursing in PDF only on Docsity!

CERTIFIED || WILDFIRE || MITIGATION || SPECIALIST ||

CWMS || Test || (Construction || Edition) || questions ||

with || accurate || detailed || solutions

ASTM || E2886 || - || correct || answer✔✔Standard || for || testing || ability || of || exterior || vents || to || resist || ember || entry NFPA || 1142 || Standard || for || Water || Supplies || for || Suburban || and || Rural || Fire || Fighting || - || correct || answer✔✔At || minimum || every || building || shall || be || provided || with || a || water || supply || meeting || requirements || of || _______________________________.

  1. || Education ||
  2. || Engineering ||
  3. || Enforcement || - || correct || answer✔✔Wildland || Fire || Mitigation || activities || fall || into || what || 3 || broad || categories? 10% || - || correct || answer✔✔Steepest || allowable || road || grade || (without || other || mitigation || measures || agreed || on || by || AHJ) NFPA || 1143 || Standard || for || Wildland || Fire || Management || - || correct || answer✔✔Which || NFPA || standard || provides || minimum || requirements || to || fire || protection || organizations || on || the || management || of || wildland || fire, || including || prevention, || mitigation, || preparation || and || suppression? Solid-core || wood || no || less || than || 1 || 3/4 || inch || thick approved || non-combustible || material or || have || a || minimum || 20 || min || fire || rating || - || correct || answer✔✔Exterior || doors || shall || be 13 || ft || 6 || inch || vertical

Unobstructed || width || of || 20ft || - || correct || answer✔✔Vertical || clearance || for || roadways || and || unobstructed || width heavy || timber, || ignition || resistant || material, || fire-retardant || treated || wood, || or || have || minimum || 1 || hour || fire || rated || construction || material || (Unless || AHJ || declares || risk || warrants || greater || protection) || - || correct || answer✔✔Exterior || walls || shall || be heavy || timber || construction, || non-combustible || material, || fire-retardant || treated || wood, || other || ignition || resistant || materials, || or || have || a || 1 || hour || fire || rating || - || correct || answer✔✔All || projections || (balconies, || decks, || etc) || shall || be || of 5/8 || inch || sheathing || or || non-combustible || materials || - || correct || answer✔✔Eaves || shall || be || boxed || in || with || _______________________________________ || or || _________________________________________. NFPA || 1144 || Standard || for || reducing || structure || ignition || hazards || from || wildland || fire || - || correct || answer✔✔Standard || which || provides || a || methodology || for || assessing || wildland || fire || ignition || hazards || around || existing || structure, || residential || developments || and || subdivisions || and || provides || minimum || requirements || for || new || construction || to || reduce || the || potential || of || structure || ignition || from || wildland || fires 6 || Inches || - || correct || answer✔✔Minimum || non-combustible || space || between || horizontal || surface || and || siding. Intermediate || Zone || - || correct || answer✔✔Extends || out || 30ft || from || foundation, || deck, || etc. Wildland || Urban || Interface || - || correct || answer✔✔Area || where || wildland || fuels || abut || structures || with || clear || line || of || demarcation || between || residential, || business || and || public || structures || and || wildland || fuels Class || B || - || correct || answer✔✔Minimum || Fire || Rating || (Class) || for || exterior || wall || materials

50ft || / || "Hammerhead || T" || Turnaround || (For || 3 || Point || Turns) || - || correct || answer✔✔Every || dead || end || fire || service || access || road || shall || be || provided || with || a || turnaround || at || the || terminus || having || a || minimum || of || __________ || or ||

___. Wildland || Urban || Intermix || - || correct || answer✔✔Area || where || structures || are || scattered || and || intermingled || with || wildland || fuels. 10 || ft || - || correct || answer✔✔Ideally || canopies || of || mature || trees || will || be || no || closer || than || __________ || to || the || edge || of || the || structure. 18 || ft || in || ILA || (0-30ft) 12 || ft || (30-60ft) 6 || fit || (60-100ft) || No || Recommendation || (>100ft) || - || correct || answer✔✔Canopy || spacing || in || Intermediate || Landscaped || Area/Defensible || Space 30-100/200 || ft Structure || Ignition || Zone || Boundaries || per || 1144 || - || correct || answer✔✔1) || Zone || Generally || extends || to || 200ft, || but || it || is || acknowledged || that || 100ft || is || sometimes || enough 2)There || is || no || mention || of || the || 0-5 || ft || zone. || "Intermediate || Landscaped || Area" || refers || to || 0-30ft. 2 || Basic || Fuel || Model || Clasificaitons || - || correct || answer✔✔1) || National || Forest || Fire || Laboratory || (NFFL) || Fire || Behavior || Fuels || Models

  1. || National || Fire || Danger || Rating || System || (NFDRS)

Flame || Spread || Index || vs || Class || Ratings || - || correct || answer✔✔A || numerical || reference || that || measures || how || fast || and || far || a || flame || spreads || during || a || 10 || minute || test. || Class || A || = || 0- Class || B || = || 26- Class || C || = || 76 || - || 200 NFPA || Standard || provides || guidance || on || development || in || the || WUI || - || correct || answer✔✔NFPA || 1141 || - || Fire || Protection || Infrastructure || for || land || development || in || wildland, || rural, || and || suburban || areas NFPA || 1140 || - || Standard || for || Wildland || Fire || Protection || (Newer || + || Consolidated) 150 || / || 150 || - || correct || answer✔✔Where || any || point || of || a || building || is || greater || than || ________________ || ft || from || a || road, || a || driveway || shall || be || provided || to || within || ___________ || ft || of || the || building. 1/8 || inch || (3.1mm) || - || correct || answer✔✔Wents || shall || be || screened || with || corrosion || resistant, || non || combustible || wire || mesh || not || to || exceed || _____________.

|| of || Parking || spaces || = || # || of || Access || Routes

0-1250 || 1 1251-3000 || 2 >3000 || 3 || - || correct || answer✔✔Required || # || of || Access || Routes || for || Non-Residential || Areas 0-100 || = || 1 101-600 || = || 2 >600 || = || 3 NFPA || 1141 || Chapter || 5 || "Means || of || Access" || - || correct || answer✔✔Required || # || of || Access || Routes || per || # || of || households>

NFPA || 256 || - || Standard || methods || of || fire || tests || of || roof || coverings ASTM || E || 108 || - || Standard || test || methods || for || fire || tests || of || roof || coverings || - || correct || answer✔✔Only || listed || roof || coverings || tested || and || rated || in || accordance || with || ________________________ || and || _____________________________ || shall || be || used. || (Specific || class || shall || be || consistent || with || hazard || analysis || completed || prior || to || construction). 30 || ft || - || correct || answer✔✔Building || closer || than || __________ || to || a || vegetated || slope || shall || require || special || mitigation || measures || as || determined || by || the || AHJ. 30 || ft || - || correct || answer✔✔Separation || distance || between || primary || and || accessory || structures || on || each || lot || and || structure || on || adjacent || lots || shall || not || be || less || than || __________.