This white paper summarizes the research progress of important academic journals in the field of cosmetic quality and safety testing technology in recent years, and introduces representative new technologies for cosmetic testing. It aims to provide theoretical support and technical reference for researchers in the field of cosmetics testing.
Typology: Study Guides, Projects, Research
1 / 8
This page cannot be seen from the preview
Don't miss anything!





The issue of cosmetics quality and safety has always been the focus of public attention. Many well-known brands of cosmetics have successively detected banned or restricted substances. This has not only harmed consumers' rights, but has also caused significant economic losses to cosmetics companies. In order to reduce or avoid the emergence of cosmetic quality and safety incidents, researchers have adopted a variety of analytical testing techniques to establish a series of detection methods for chemical risk substances in cosmetics. This white paper summarizes the research progress of important academic journals in the field of cosmetic quality and safety testing technology in recent years, and introduces representative new technologies for cosmetic testing. It aims to provide theoretical support and technical reference for researchers in the field of cosmetics testing.
In the process of cosmetic sample detection, pretreatment is usually the most critical and time-consuming step, and it is also an important step to concentrate the target components, improve the sensitivity of the method and remove interferers. The matrix of cosmetic samples is mainly oily raw materials and water. The former includes oils, waxes, hydrocarbons, and the higher fatty acids and fatty alcohols that make up these ingredients. Various components, such as spices, preservatives, colorants, water-soluble
polymers, humectants, surfactants, metal ion adhesives and other components, are added to the matrix to make cosmetics. Therefore, the matrix in cosmetics is very complex, and there may be some interference effects in the analysis and detection of target compounds. The accuracy and reliability of the analysis results are directly determined by the sample pretreatment effect. At present, the extraction technologies reported in cosmetics testing include ultrasound-assisted extraction, mechanical vibration extraction, liquid-liquid extraction, dispersion-liquid microextraction, solid-phase microextraction, and supercritical fluid extraction, etc. The purification technology is mainly solid-phase extraction, N-hexane degreasing, etc. Extraction Technology Ultrasound-assisted Extraction Ultrasound-assisted extraction (UAE) is easy to operate and can achieve high extraction efficiency in a short time. It is the most commonly used technical means for extracting organic components in cosmetics. As an extraction technology, the cavitation effect produced by ultrasonic waves occupies the main aspect. This effect can refine various substances and generate emulsions, accelerating the target components in the sample into the solvent. In addition, the thermal effects and mechanical effects produced by ultrasound are two important bases for its use as an extraction technology. Extraction technology is mostly used to detect hormones (glucocorticoids, androgens, estrogen, and progestogens), antibiotics (sulfonamides, nitrofurans, quinolones, and nitroimidazoles) and preservatives in cosmetics, and good recovery and precision are obtained. Mechanical Vibration Extraction Mechanical vibration extraction technology can improve the turbulence degree of the solvent and reduce the thickness of the mass transfer interface between the sample and the solvent, so as to improve the extraction rate and efficiency. The main characteristics of this technology are high solvent utilization and extraction efficiency, but strong selectivity for extraction solvents. 9 kinds of glucocorticoids in cosmetics were extracted
the target, eliminating tedious operation steps, greatly reducing analysis time and improving analysis efficiency. In cosmetics testing, a solid-phase microextraction method was developed for 8 phthalate plasticizers in water-soluble cosmetics. After the samples were diluted with water and sealed with sodium chloride, they were stirred in the silicone oil bath for headspace extraction, and then the extraction fiber head was placed in the gas-phase chromatogram inlet for desorption. The recoveries of all analytes were 83% - 97% and RSD was 2.5% - 10.0% Supercritical Fluid Extraction Supercritical fluid extraction(SFE) uses supercritical fluid as extractant to extract target analytes from liquids or solids so as to achieve the purpose of separation. The technology has the following advantages: easy separation from the product, safe and non-toxic, mild operating conditions, not easy to destroy the active components and so on. In recent years, some analysts have applied supercritical fluid technology to the field of cosmetic detection. This technique has been used to extract four Nipagin ester preservatives and four antioxidants from cosmetics. Purification Technology Solid-phase Extraction Solid-phase extraction (SPE) is a technology developed from the combination of liquid- solid extraction and liquid chromatography. It separates, purifies and enriches samples through selective adsorption and desorption of sample components by fillers. The main purpose is to reduce matrix interference in samples and improve detection sensitivity. Because of its simple operation, high recovery rate and good repeatability, this technique is widely used in the field of cosmetic detection. For example, solid phase extraction technology is used to remove the matrix components in the samples in the purification process of hormones, surfactants, halogenated phenols, prohibited drugs and coumarins, which can effectively reduce the interference to the target analytes.
N-hexane Degreasing As most of the matrix in oily cosmetics are non-polar fatty components, it is a simple and easy method to remove most of the non-polar matrix by adding n-hexane.
HPLC and HPLC-MS High-performance liquid chromatography (HPLC) is suitable for the separation of 80% known organic compounds because it is not restricted by the volatility and thermal stability of the substances to be determined. It has the characteristics of fast analysis speed, strong separation ability, high sensitivity and a wide range of applications. In recent years, analysts have established a method for the detection of a variety of prohibited components in cosmetics by using HPLC, such as hormones, dyes, preservatives, sulfonamides, nitrofuran antibiotics, catecholamines, allergens, coumarins, phthalates, ultraviolet absorbers, zinc phenol sulfonate, benzalkonium chloride, antihistamines, naphthalene diphenols, formaldehyde, vitamins, halogenated phenols, quinolones antibiotics, colorants and so on. High-performance liquid chromatography-mass spectrometry (HPLC-MS) technology is used for cosmetics sample detection. Multiple reaction monitoring (MRM) mode of tandem quadrupole mass spectrometry is favored. In this model, the characteristic parent ions are detected first, and the interference of other fragment ions can be removed after further collision induced dissociation (CID) of the selected parent ions. Only the selected characteristic ions are collected by mass spectrometry. Through the selective monitoring of secondary ions, the chemical background of mass spectrometry detection can be reduced, and the signal-to-noise ratio of the target can be significantly improved, thus the detection sensitivity can be improved. GC and GC-MS
establish an analytical method for iodate and bromate in cosmetics, and an ion chromatography was used to detect ammonium and six alkylamines in cosmetics. Ion Mobility Spectrometry The basic principle of ion mobility spectrometry (IMS) is: after the sample is converted into ions at the ion source, it is driven by the electric field, and the ions enter the weak electric field migration region through the ion gate that is periodically opened. During the continuous collision of molecules, due to the differences in the respective migration rates in the electric field, different ions are separated and reach the detector one after the other. At present, trace detection methods based on ion mobility spectrometry are mostly used in the fields of drug detection, explosives detection, and food safety. There are relatively few applications in the field of cosmetic detection.
To sum up, there are a variety of extraction and purification technologies available in the process of cosmetic pretreatment. According to the literature reports in the past decade, ultrasound-assisted extraction has become the most widely used extraction technology because of its high efficiency, easy operation and universality in the extraction of restricted substances in cosmetics. However, according to actual requirements, continuous operation is required if the sample processing volume is large. According to the specific physical and chemical properties of the target substance, liquid-liquid extraction technology is also one of the commonly used extraction methods. In recent years, with the rise of green extraction technology, disperse liquid-liquid microextraction, solid-phase microextraction and supercritical fluid extraction are more and more used in the field of cosmetics. These emerging technologies use only a small amount of organic solvent or no solvent, and the detection is fast and reliable. It can be predicted that in the cosmetic pretreatment technology, high efficiency, high speed and environmental protection is an important development direction in the future.
In terms of instrumental analysis technology, the current mainstream detection technology for cosmetics is still HPLC, GC, or a combination of both and MS. Especially in the simultaneous qualitative and quantitative analysis of multiple components, the combination of chromatography and MS shows powerful separation and detection capabilities. However, any technology has its specific advantages and disadvantages. The traditional GC-MS technology requires the use of large desktop instruments, which is expensive, high maintenance cost and high consumption of organic solvents. In recent years, the emerging ion mobility spectrum overcomes the above shortcomings of the traditional chromatography-mass spectrometry technology, does not need complex sample pretreatment process, and the analysis speed is fast, which belongs to the environment-friendly analysis technology. At the same time, the equipment is small and easy to carry, which makes the real-time detection on site possible. As people pay more and more attention to the concept of healthy consumption, it can be predicted that rapid, sensitive, high-throughput, low-cost and environment-friendly analysis and testing methods will become an important development direction of cosmetic quality and safety testing technology in the future.