General Electrician Certification
Practice Questions. Latest edition
2026-2027. Questions & Correct
Answers. Graded A
After calculations there is a load with 75 amperes, the load needs a breaker
or fuse of at least ____ amps. - ANS80 Amps
Before demand factors are taken into consideration for commercial
building, general purpose receptacle loads are to be computed at not less
than ___ VA per single or duplex receptacle? - ANS180 VA
How many hours is considered continuous load and its percentage when
calculating a continuous load? - ANS3 hours or more and calculated at
125% percent
How many VA are required in a barbershop? - ANS33 VA
How many VA are required in a restaurant? - ANS22 VA
in a health care facility, low voltage electrical equipment that is likely to
become energized and is frequently in contact with the bodies of patients
shall operate on a voltage of ____ volts or less if the equipment is not
pf3

Partial preview of the text

Download General Electrician Certification Practice Questions. Latest 2026-2027. Graded A and more Exams Electrical Engineering in PDF only on Docsity!

General Electrician Certification

Practice Questions. Latest edition

2026-2027. Questions & Correct

Answers. Graded A

After calculations there is a load with 75 amperes, the load needs a breaker or fuse of at least ____ amps. - ANS80 Amps Before demand factors are taken into consideration for commercial building, general purpose receptacle loads are to be computed at not less than ___ VA per single or duplex receptacle? - ANS180 VA How many hours is considered continuous load and its percentage when calculating a continuous load? - ANS3 hours or more and calculated at 125% percent How many VA are required in a barbershop? - ANS33 VA How many VA are required in a restaurant? - ANS22 VA in a health care facility, low voltage electrical equipment that is likely to become energized and is frequently in contact with the bodies of patients shall operate on a voltage of ____ volts or less if the equipment is not

approved as intrinsically safe, double insulated, or moisture resistant. - ANS10 volts or less In an installation with schedule 40 pvc conduit system that consists of 50 ft. in length between pulling point, what is the maximum number of bends permitted? - ANSMaximum of four (4) 90-degree bends permitted In general, when a size 4 AWG or larger insulated conductor enters a panelboard, cabinet, or enclosure, which of the following must be provided?

  • ANSAn insulated bushing Show Windows shall be calculated at _____ VA per feet? - ANS200 volt- ampere There is a circuit rating 20 amperes, what receptacles can we use? - ANS15 or 20 ampere receptacles What are standard ampere rating for breakers and fuses? - ANS15,20,25,30,35,40,45,50,60,70,80,90,100,110,125,150,175,200, what does VA stand for? - ANSVolt-Amperes What is the disconnect purpose? - ANSto prevent ungrounded conductors to pass to the service.