HOME INSPECTOR FLORIDA TEST PRACTICE QUESTIONS, Exams of Advanced Education

HOME INSPECTOR FLORIDA TEST PRACTICE QUESTIONS

Typology: Exams

2024/2025

Available from 11/20/2024

alex-david-34
alex-david-34 🇿🇦

4.5

(4)

5.6K documents

1 / 9

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
HOME INSPECTOR FLORIDA TEST
PRACTICE QUESTIONS
Air-admittance valves are __________ to vent fixtures installed at island structures in
kitchens. - Permitted
The door between an attached garage and a dwelling unit should be of solid wood not
less than ________ inches thick. - 1 3/8
If particleboard panels used as wall sheathing are applied in a horizontal pattern across
the wall, the end joints should be offset so that four panel corners ________. - do not
meet
The size of a P-trap drainpipe should be at least _______ inches. - 1.5
Notches in solid lumber joists, rafters and beams should not be longer than
____________ the depth of the member. - 1/3
A minimum service of _____ amps is required for a single residential dwelling unit. - 100
If the service or feeder rating in amps is 200, then the aluminum AWG size should be
_______. - 4/0
T/F: In homes located in areas having a history of ice forming along the eaves, an ice
barrier consisting of at least three layers of underlayment cemented together is
required. - True
There should be at least ____-inch gypsum board applied on the garage side to
separate the garage from the residence and its attic space. - 1/2
A window well should have a horizontal area of at least ____ square feet, with a
minimum horizontal projection and width of _____ inches. - 9 and 36
The opening to an attic space that has any mechanical equipment located in it should
be a minimum of ______ inches by ______ inches. - 30 and 20
If there are appliances in the attic space, an opening at least _____ and a clear,
unobstructed path should be provided. - 22 inches wide and 30 high
Standpipes for clothes washers should extend at least ____ inches and no more than
____ inches above the trap weir. - 18 and 42
T/F: A standpipe can serve as an indirect waste receptor. - True
pf3
pf4
pf5
pf8
pf9

Partial preview of the text

Download HOME INSPECTOR FLORIDA TEST PRACTICE QUESTIONS and more Exams Advanced Education in PDF only on Docsity!

HOME INSPECTOR FLORIDA TEST

PRACTICE QUESTIONS

Air-admittance valves are __________ to vent fixtures installed at island structures in kitchens. - Permitted The door between an attached garage and a dwelling unit should be of solid wood not less than ________ inches thick. - 1 3/ If particleboard panels used as wall sheathing are applied in a horizontal pattern across the wall, the end joints should be offset so that four panel corners ________. - do not meet The size of a P-trap drainpipe should be at least _______ inches. - 1. Notches in solid lumber joists, rafters and beams should not be longer than ____________ the depth of the member. - 1/ A minimum service of _____ amps is required for a single residential dwelling unit. - 100 If the service or feeder rating in amps is 200, then the aluminum AWG size should be _______. - 4/ T/F: In homes located in areas having a history of ice forming along the eaves, an ice barrier consisting of at least three layers of underlayment cemented together is required. - True There should be at least ____-inch gypsum board applied on the garage side to separate the garage from the residence and its attic space. - 1/ A window well should have a horizontal area of at least ____ square feet, with a minimum horizontal projection and width of _____ inches. - 9 and 36 The opening to an attic space that has any mechanical equipment located in it should be a minimum of ______ inches by ______ inches. - 30 and 20 If there are appliances in the attic space, an opening at least _____ and a clear, unobstructed path should be provided. - 22 inches wide and 30 high Standpipes for clothes washers should extend at least ____ inches and no more than ____ inches above the trap weir. - 18 and 42 T/F: A standpipe can serve as an indirect waste receptor. - True

An open vent pipe that passes through a roof should extend at least _____ inches above the roof. - 6 If a roof is used for a purpose other than weather protection, the vent extensions should extend above the roof by at least ____ feet. - 7 If particleboard is used as wall sheathing, the grade mark with Type _____ or _____ should be stamped on it. - M-1 and M- The purpose of gravel on a built-up tar-and-gravel roof is __________. - to prevent delamination of the plys to protect the membrane from ultraviolet rays to provide ballast to help hold down the roof membrane A roof that has a problem with ponding generally still has water on it at least ____ hours after it has rained. - 48 The purpose of a cant strip is to __________. - prevent the roof membrane from cracking at a change in direction The roofing material having the shortest life expectancy is __________. - roll roofing A retaining wall ___________. - is used to prevent soil movement When lowering a basement floor, if the soil is excavated only to the bottom of the footing, it may result in _____________. - loss of lateral support for the footing The minimum end-bearing for beams is _____ inches. - 3-5/ A load-bearing stud wall has a ____________. - double top plate and a single sole plate Truss uplift is believed to be caused by ___________. - a differential in humidity levels within an attic T/F: It is preferable to have downspouts discharge below grade rather than above grade. - False T/F: Stucco over wood framing exhibits significantly fewer cracks than stucco over masonry walls. - False Stucco cracks and bulges often appear near the floor level because __________. - wood framing shrinks the most in this area

There must be at least _____ of clearance in front of the toilet to any wall, fixture or door. - 21 If a plumbing vent extends too far above the roof line, there is a risk of ____________. - Frost Closure In new-construction homes, the minimum pipe size for the main water supply line is ______. - 3/4 inch The plumbing fixture notorious for leakage through small openings in the grout, caulking and/or weatherstripped areas is the _________. - Shower The main difference between brass and copper supply pipes is _______________. - brass pipes have threaded joints and copper pipes have soldered joints Plumbing stacks should terminate ____ feet horizontally from a window. - 10 Water hammer can be corrected by ____________. - re-fastening loose pipes and installing air chambers or shock absorbers The most common supply piping material used in modern home construction is __________. - Copper The power available in a typical 15-amp, 120-volt household circuit is _____ watts. - 1, Linking _________________. - ensures that two fuses or circuit breakers are disconnected at the same time The service entry size for a 200-amp service is ___________. - #2/0-gauge copper The only suitable receptacles for use with aluminum wire should be marked ______. - CO/ALR A kitchen split-receptacle is a ____________. - duplex receptacle whose top and bottom halves are on individual dedicated circuits A service mast must be used with a service drop if the _____________. - weatherhead does not clear the roof by 3 feet T/F: The purposes of bonding and grounding are the same. - False A forced-air heating system that is fueled by oil is evidenced by the presence of a ___________. - barometric damper

In a steam-heating system, the operating cut-off control is set at _____ psi. - 2 to 3 A radiant-heat systems uses _________ to radiate heat. - pipes and panels and/or entire walls, floors and/or the ceiling For fire safety, oil burners usually have ____________. - either a stack switch or a photo-electric device The typical range at which a fan/limit switch will turn the blower on is _______. - 130° to 150° F Pressure-reducing valves on hot-water heating systems are typically set at _________.

  • 12-22 psi For a conventional gas furnace, about ________ per 1,000 BTUs of ventilation for combustion air should be provided. - 2 square inches The ________ confirms ignition of the pilot light. - thermocouple Cleanouts for drainage pipes should be installed _____________ apart in horizontal drainage lines measured from the upstream entrance of the cleanout. - Not More Than 100 Feet House wrap is designed to ___________ water vapor to pass through it. - Allow A home inspector will typically find the ______-port burners installed in a furnace with a forced-draft, as they are common with high-efficiency furnaces. - Mono The required egress door has to provide a clear space of at least ___ inches wide, measured from the door surface to the door stop when the door is open at a 90 degree angle. - 32 The minimum height for a stair riser is ________. - 4 in Footings for masonry chimneys must be made of concrete or solid masonry at least _____ thick. - 1 Foot The minimum clearance from an exhaust flue on a conventional oil furnace to combustibles is ____ inch(es). - 9 Cracks at interior walls are not caused by ____________. - a lack of insulation Ideally, exterior doorways should be _______________. - installed with a step-up of at least 6 inches

What kind of connector is required to connect attach plastic DWV to cast iron DWV? - Hubless What does voltage measure? - Electrical Pressure What breaker amperage can these copper wires go to in order? 8,10,12,14 - Amperages 40,30,20, How might rafter spread be noticed from the exterior of the home? - Separation of the soffits from the wall What type of roof requires an underlayment of felt between courses? - Wood shakes 4 ply built up roof would have? - 4 layers of felt and 4 layers of bitumen What siding has a tendency to expand and contract the most? - Vinyl What is the lightest type of copper piping? - Type M What is the purpose of a Hartford Loop? - Precludes siphon action if the unit develops a leak Another name for a 4 way valve is a? - Reversing Valve What is the purpose of an accumulator? - Keep liquid refrigerant out of the compressor The most likely area to find a crack or hole in the heat exchanger is in the? - Front and behind the heat shield Visualize a basement stairway with a wall on one side, what is not a safety defect? - No handrail on the wall side Three wires on a masthead, one tied back. What kind of service? - 120 Volt Service When does the defrost cycle on a heat pump normally turn on? - At 37 or below degrees F A dirty air filter can cause? - Reduced air flow and lower return air temperature A metering device is used to? - Reduce pressure on the coolant In the cooling cycle of a heat pump, the condensing coil is located? - Outside How long will a defrost cycle on a heat pump last in the heating season? - 10 minutes T/F: Styrofoam insulation is a potential carcinogen - False

SE cable should be ___ from earth at the SE entrance, ___ from a driveway, and ___ from a window - 10 feet, 12 feet, 3 feet What is the minimum height of SE cables above a roof? Above a roof with a slope greater than 4:12? - 8 feet 3 feet What is the minimum bearing of a wooden beam on a masonry column? - 3 inches When does a built up roof need flood coating? - When the tar paper is showing A 30 amp plug fuse is usually what color? - Green Where a roof ridge is closer than 10 feet to a chimney, the stack should be _______ higher. - 2 A built up roof having a lap joint every 12" has how many plys? - 3 ply Wood shakes and shingles are best maintained by? - Applying a quality water seal coating periodically Electrical resistance is measured in? - Ohms Electrical current flow is measured in? - Amperes If a black wire carries 10 amps, how much will the white wire carry? - Same as the black wire Tempered glass is safer than regular glass because? - It breaks into small rectangular pieces For water to drain freely from a houses waste system, there must be adequate? - Venting The temperature differential at the air return handler of a heating system in heating mode should be? - 10- The anode rod in a water heater does what? - Protects the tank from corrosion Glass block is not? - Safety Glazed Substantial movement of a building will not be caused by? A. Missing lintels B. Missing frost footings C. Soft Soil