Investigatory Project on AC Transformer
Typology: Study Guides, Projects, Research
1 / 9
This page cannot be seen from the preview
Don't miss anything!






Date: Internal Examiner (Subject Teacher) Signature Principals Sig nature External Examiner Signature
Acknowledgement
Sign.
AC TRANSFORMER
Aim of the project:
Output power at the same instant = Es Is If there are no losses of power in the transformer, then Input power = output power Or Ep Ip = Es Is Or Es / Ep = Ip / Is = K In a step up transformer As k > 1, so Ip > Is or Is < Ip i.e. current in sec. is weaker when secondary voltage is higher. Hence, whatever we gain in voltage, we lose in current in the same ratio. Similarly it can be shown, that in a step down transformer, whatever we lose in voltage, we gain in current in the same ratio. Thus a step up transformer in reality steps down the current & a step down transformer steps up the current. How to Wire a Step Down Transformer Observe and identify the schematic and rating of the step down transformer to be installed. Remove the terminal connection box cover placed at the lower side of the transformer. Only the high amperage types will have this enclosure, while lower powered transformers will have an exposed screw terminal. Know termination identification follows for all step down transformers: H1, H2, H3 and H4 signify the high voltage side or power feed end of the transformer. This holds true regardless of the size of the transformer. Interconnection of the transformer will vary depending on the manufacturer and voltage used for feeding the transformer.
Terminate the feed power wires first by cutting the wires to length. If you are using large wire lugs be sure to take into consideration the length of the lug and the amount of wire that can be inserted into the female crimp area. Strip back the outer insulating of the wires with the pocketknife or wire strippers. Insert the eye ring or wire lug over the bare copper wire and crimp the connection device, using the appropriate-size crimper, permanently to the wire. Terminate the high side, high voltage of the step down transformer. If the high side terminals are bolts, be sure to follow any torque requirements that are listed by the manufacturer. Terminate the low side, low voltage of the transformer. Note these terminals will be identified by X1, X2, X3 and X4. Again follow the manufacturer's individual schematics for that particular type of transformer. Note that on small control transformers there will only be an X1 and X2. X1 is the power or "hot" side and X2 is generally the grounding and neutral portion of the low voltage. Terminate the small control transformer for X1 and X2. X1 will go directly to the control circuit after passing through a small fuse that is rated for the circuit. X2 will be terminated not only to the neutral side of the control circuit, but the grounding safety as well. In other words, the X2 side of the small control transformer must be tied to the grounding system of the electrical circuit. Replace all covers on the transformer and any enclosures that protect you from electricity. Apply the high voltage to the transformer by switching on the feeder power circuit. Turn on the low side safety circuit control. Use a volt meter to test for proper voltage on the step down side of the transformer. It should be the same that is listed on the specs tag provided by the manufacturer. Observation: Following are the major sources of energy loss in a transformer: