According to the IBC, which of the following cases are exceptions to where special inspections are required? - Answers- • Building components where a design professional is not required
Given: a bolt length less than 4 times the bolt diameter where both faces of the joint are normal to the bolt axis. According to the Specification for Structural Joints, what is the required nut rotation beyond snug tight for the turn of the nut method of installation? - Answers- 1/3 turn According to the Specification for Structural Joints, the faying surfaces of ______ joints are important in the performance of the joint when stressed - Answers- Slip critical The special inspector shall perform an inspection of ______ to verify compliance with the details shown on the approved construction documents such as bracing, stiffening, member locations, and proper application of joint details at each location - Answers- The steel frame The special inspector need not to be continuously present the welding of: - Answers- Single-pass fillet welds not exceeding 5/16 inch in size According to the Specification for Structural Steel Buildings, the ________ identifies each primary structure was still a member, so it is placed in the correct location in the building. - Answers- Fabricator According to the Specification for Structural Joints, the nominal diameter of an oversized bolt hole for a 1- inch diameter bolt is _____ inches - Answers- 1 - 1/ According to the Specification for Structural Joints, what is the purpose of tension calibrator testing of the method of bolt installation used on the job site? - Answers- To verify the method of bolt installation has achieved the required bolt tension The Specifications for Structural Joints stars "the tightness that is attained with a few impacts of an impact wrench or the full effort of an iron worker using an ordinary spud wrench to bring the plies into firms contact" this is the description of which method of high-strength bolt installation? - Answers- Snug tight According to the Specification for Structural Joints _______ is the minimum bolt pretension required for an A325 bolt 1 1/4 inch in diameter - Answers- 71 kips According to the Specification for Structural joints, where the turn of the nut method of bolt installation is used, how often is a special inspector to observe the work as it progresses? - Answers- Periodically Thermally cut surfaces shall be ground smooth for: - Answers- Cyclically loaded joints Fasteners components that accumulate rust or dirt shall not be incorporated into the work unless they are: - Answers- Prequalified
According to the Specification for Structural Steel Buildings, what fabrication process is to be used on column ends for a compression joint that depends on contact bearing for transfer of load? - Answers- Milled ends According to the Specification for Structural Steel Buildings the document which includes the required dimensional tolerances for structural steel is the: - Answers- Code of Standard Practice for Steel Buildings and Bridges According to the Specification for Structural Steel Buildings, the special inspector can check an individual structural steel member to see that it is the proper one for a certain location in the building by viewing the: - Answers- The fabricators marking on the member which matches the location of that member on the shop drawings According to the AISC Steel Construction Manuel, which of the following is not an allowed manner for setting column base plates? - Answers- Treated hardwood shims According to the AISC Steel Construction Manual, the grout used between the column base plate and the foundation must be: - Answers- High-strength non-shrink What is the maximum steel temperature allowed to correct camber in an A514 structural steel beam - Answers- 1,100 F According to the Code of Standard Practice for Steel Buildings and Bridges, what party is to review the fabricator's ship and erection drawings? - Answers- Owner's representatives for design and construction According to the code of standard practice for steel building and bridges, the ________ must be approved before the fabrication of the structural steel begins. - Answers- Shop and erection drawings According to the code of standard practice for steel buildings and bridges ______ is the tolerance on the length of a floor beam that is less than 30 feet long - Answers- 1/ inch According to the code of standard practice _____ of the steel surface is required prior to shop painting - Answers- Wire brushing According to the code of standard practice for steel buildings and bridges the permitted method of applying shop paint is: - Answers- • Brushing
Which section of the code of standard practice for steel buildings and bridges includes the permitted tolerances for detailed erection? - Answers- Section 7. According to the code of standard practice for steel buildings and bridges ______ are(is) allowed in moderate amounts for correction of errors during steel framing erection. - Answers- • Drifts Pins