TCFP FIRE INSPECTOR 2 EXAM FINAL SCRIPT 2026 COMPLETE SOLUTION SET
Typology: Exams
1 / 32
This page cannot be seen from the preview
Don't miss anything!

























โ Administrative duties. Answer: Processing permits Applications Plans review New policies Respond to complaints Keeping records of written and spoken correspondence โ time management skills. Answer: specific strategies for planning and using time in effective, healthful ways and complete your duties โ Purpose of field inspections. Answer: Verify whether buildings are meeting federal, state, and local fire prevention codes. โ Requirements of field inspection. Answer: Assessment of the outside and surrounding premises. Know and understand the fire safety codes and standards adopted in thier jurisdiction โ Plans review. Answer: Process of reviewing building plans and specifications to determine the safety characteristics of the
proposed building generally done before permission is granted to begin construction โ appropriate dress code. Answer: Follows department regulations professional and neat shows organization and preparation for the job โ Effective fire prevention education program. Answer: Positive Impressions Relationships with other agencies community educational programs National fire prevention week activities โ The two documents that establish the legal and ethical authority for fire inspection within the military. Answer: DODI 6055.06 (DOD Fire and Emergency Services Program) UFC 3- 600 - 01 (Fire Protection Engineering for Facilities) โ DODI 6055.06 (DOD Fire and Emergency Services Program). Answer: Establishes the foundation for fire pervention and education program
โ determining wheter a hot work permit should be given:. Answer:
โ once permit has been issued, inspector must check what?. Answer: work is completed within the specified time limit and guidelines. โ How many people must be able to exit through the main entrance of an assembly occupancy?. Answer: At least one half of the occupant load โ Corridor width requirement for educational occupancy?. Answer: 72 inches or no less than 6 ft โ How far away from an exit should a fire alarm pull station be?. Answer: 5 feet or 60 inches away from the exit on each floor โ What is the max distance allowed between a fire hydrant and the fire department connection?. Answer: 150 feet โ A classroom at a local university is not classified as educational because:. Answer: Educational occupancies only go through 12th grade โ A fire department connection for a sprinkler system must:. Answer: Have a cap on it that can be removed easily
โ On a set of construction drawings, a pair of parallel lines is usually the symbol for:. Answer: A wall โ On a set of construction drawings, to see a two dimensional look at a building, you would refer to the?. Answer: Elevation plan โ A typical error fire inspectors find in mathematical calculations on the set of drawings is?. Answer: Occupant load factor โ Unlike fire inspector one, fire inspector to has a duty to. Answer: Review plans โ What is the first thing a fire inspector should do when a permit application is submitted?. Answer: Make sure the permit application is filled out completely โ Plans review applications requirement. Answer: 1.Fire inspector is responsible for making sure the appropriate sections are completed
โ Complaints about how problems are made within the inspection process as a whole can be addressed by?. Answer: Creating a new or revising an existing SOP โ Minimum vertical clearance for a fire lane?. Answer: 13'6" โ Evacuation routes should have. Answer: A primary and secondary route โ Special amusement buildings should be classified as?. Answer: Assembly occupancies โ A mixed use occupancy consist of more than one different occupancy under one roof that?. Answer: Is not separated by a fire resistance rated occupancy separation โ When two buildings are separated by a fire wall they are considered to be what?. Answer: Separate buildings โ The minimum Corridor with is determined by. Answer: The number of people in the type of occupancy โ The maximum height for doorway threshold. Answer: Half inch
โ NFPA 204. Answer: Standard for smoke and heat venting โ The standard that provides testing requirements for fire protection systems is what?. Answer: UFC 3- 601 - 02 โ The type of fire protection system required for most areas with hazardous materials is a. Answer: Dry chemical system โ Regardless of the weight of a fire extinguisher, the distance between the bottom of the extinguisher in the floor should never be less than what distance?. Answer: Should never be less than 4 inches โ How often should a 12 year hydrostatic test fire extinguisher be emptied and subjected to maintenance procedures. Answer: Every six years โ In a dipping and coating area, the ventilation system must contain vapors to within?. Answer: 5 feet of the source โ Common hazards associated with HVAC equipment. Answer: Clogged filters Improperly adjusted fan belt drives Combustible lint or debris near burners
โ NFPA 1031. Answer: Standard for Professional Qualifications for Fire Inspector and Plan Examiner โ In a sprinkler system, water is distributed directly to branch lines by?. Answer: Cross mains โ Who provides contact and logistical information on the plans review application?. Answer: The applicant for the plans review โ FM-200. Answer: Clean agent โ When on-scene to investigate a complaint:. Answer: 1. Bring facility folder
โ one way to raise the level of fire prevention awareness in your community is to:. Answer: conduct community educational programs โ what should a fire inspector take if the conditions of the permit are not met by the permit applicant?. Answer: revoke the permit โ plans review applications. Answer: vary from jurisdiction to jurisdiction โ Three critical elements that the fire inspector must validate during an inspection:. Answer: 1. Fire department emergency access
โ NFPA 1 requires what of buildings that are 150' away from a paved road?. Answer: fire department access roads or fire lanes be provided. โ When is a cul-de-sac turnaround required?. Answer: road is a dead end and exceeds 150' โ What facilities must provide suitable all-weather ground access surface for aerial apparatus on a minimum of two sides?. Answer: New facilities four stories or more in height and all new warehouses โ A building 5000 sq ft or more than two stories must have:. Answer: at least one means of all-weather ground access. โ All emergency evacuation plans should have three basic components:. Answer: 1. Evacuation routes
โ Mixed Occupancy. Answer: When a building or area of a building contains two or more occupancies. โ Separated Occupancy. Answer: A multiple occupancy where the occupancies are separated by fire resistance-rated assemblies. โ Height of Building. Answer: distance measured from the ground to the average height of the highest roof surface. โ Type 1 construction. Answer: Fire-Resistive Construction usually reinforced concrete type structure and protected by automatic sprinklers. โ Type 2 construction. Answer: Non-combustible, fire resistant ratings on almost all building materials, usually have a flat roof, warehouse type building โ Type 3 construction. Answer: Ordinary construction requires that exterior walls be made of non-combustible material, the roofs or partially are completely made of wood โ Type 4 construction. Answer: Heavy-timber construction, mostly everything in the building is made of solid or lamented wood.
โ Type 5 construction. Answer: Wood-frame construction, used in single family homes or in buildings up to 7 stories โ The area of a building is measured:. Answer: within the exterior walls of one story โ The distance measured vertically, from the top of one finished floor surface to the top of the floor surface above:. Answer: A story โ additions that increase the floor are more than 50% of the overall building must meet code guidelines for:. Answer: New construction โ A daycare home must provide care to:. Answer: between 3 and 12 children โ Difference between a dry pipe system and a wet pipe system is:. Answer: Dry pipe system is held back by air pressure, wet pipe system has water throughout. โ Identify the five types of standpipe systems. Answer: 1. Semiautomatic-dry
โ NO EXIT signs. Answer: All letters in NO must be 2 inches high, and all letters in EXIT must be 1 inch high. โ 30 - second emergency lighting test is required every?. Answer: Month โ Exit Discharge. Answer: That portion of the means-of-egress system between the termination of the exit and a public way. โ a dead end corridor in a new unsprinklered business occupancy building may be acceptable if the length of the corridor is less than:. Answer: 20 feet โ Under what conditions may an elevator be used as a means of egress?. Answer: 1. Structure is protected throughout by an automatic sprinkler
โ Area of Refuge. Answer: โ Area of Refuge. Answer: An area where people unable to use stairways can remain temporarily while waiting for assistance โ Clear Width. Answer: Actual unobstructed opening size of an exit, measured from the narrowest point in the door opening and for swinging doors, between the face of the door and the door stop. โ Door width. Answer: 32 inches at minimum โ How do you determine the minimum width for doors?. Answer: use the clear width measurement, unless door leaf is specified. โ Doors for rooms with an occupant load of 50 or more must:. Answer: must swing in the direction of exit or egress travel โ During door swing the door must not leave less than what length in the corridor?. Answer: no less than on=half required width of corridor and shall not project more than 7 inches into the required width or a corridor. โ Doors opening onto stairs:. Answer: Shall not open directly onto a stair without a landing