TCFP INSPECTOR CLASS II EXAM SCRIPT 2026
FULL SOLUTION SET
◉ Steel Hoods Answer: Made of 18 Gauge Steel, 18'' Clearance to
combustible
◉ No more than ____ actions for a pull station Answer: 2
◉ Deep Fryer shall have ___ space between other cooking surfaces.
Answer: 16"
◉ Minimum distance you can store within a sprinkler head Answer:
18 Inches
◉ Sprinklers are designed to operate at _____ PSI Answer: 15
◉ Minimum distance from a hydrant to the ground is Answer: 18''
◉ Every suppression system for a kitchen should be Answer: Type K
◉ Maximum travel distance for a B rated extinguisher is Answer: 50
Feet
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23
pf24
pf25
pf26
pf27
pf28
pf29
pf2a
pf2b

Partial preview of the text

Download TCFP INSPECTOR CLASS II EXAM SCRIPT 2026 FULL SOLUTION SET and more Exams Public Policy in PDF only on Docsity!

TCFP INSPECTOR CLASS II EXAM SCRIPT 2026

FULL SOLUTION SET

◉ Steel Hoods Answer: Made of 18 Gauge Steel, 18'' Clearance to combustible ◉ No more than ____ actions for a pull station Answer: 2 ◉ Deep Fryer shall have ___ space between other cooking surfaces. Answer: 16" ◉ Minimum distance you can store within a sprinkler head Answer: 18 Inches ◉ Sprinklers are designed to operate at _____ PSI Answer: 15 ◉ Minimum distance from a hydrant to the ground is Answer: 18'' ◉ Every suppression system for a kitchen should be Answer: Type K ◉ Maximum travel distance for a B rated extinguisher is Answer: 50 Feet

◉ If a suspended ceiling is within ____ inches of the ceiling sprinklers are not required Answer: 6 ◉ To pass the "Pill Test" how many times must a match go out? Answer: 7 out of 8 Times ◉ E value of Steel is Answer: 29 Million ◉ RPM is Answer: Robertson Protected Metal ◉ Corner Test is done on Answer: 25 Foot Walls ◉ Carbon monoxide can be as much as ____ times greater in concealed spaces than in the open Answer: 50 ◉ In masonry buildings, a simple wood beam can span up to Answer: 25 Feet ◉ Wood and Paper release Answer: 8000 BTU ◉ Plastics and combustible liquids release Answer: 16,000 BTU

◉ A fire load rating of 11-15 in pounds per square inch is considered: Answer: Moderately Severe ◉ More fire fighters have been killed in ________ construction Answer: Ordinary ◉ In a Dust Explosion the 1st explosion is followed by Answer: a bigger one ◉ How much clearance in height and width is required for a public way Answer: 10 Feet ◉ What is an exploded pictorial drawing? Answer: Parts of the assembly are separated to better illustrate ◉ What is a bond? Answer: The pattern in which masonry units are laid ◉ What causes heat and smoke to spread upward then outward within a building? Answer: Convection ◉ A disadvantage of a dry chemical extinguisher? Answer: Residue

◉ What is the fire resistance rating of an exit door in buildings 3 stories or less? Answer: 1 Hour ◉ A short squat column is called? Answer: Pier ◉ The access opening to fire escapes shall be no higher than ____ inches above the floor. Answer: 12 ◉ Amps Answer: Measure the quantity ◉ Volts Answer: Measure the pressure ◉ Ohm Answer: Measures the resistance ◉ For a building to be classified an apartment, how many units with independent kitchens are needed? Answer: 3 or More ◉ To be classified as a dormitory, how many people must it provide sleeping accommodations for? Answer: More than 16 persons ◉ A structure will sustain its greatest load when the load is Answer: Axial

◉ Fire Command Center Answer: A room or area of a building where the status of the fire alarm equipment and there critical building systems associated with fire alarm systems can be manually controlled. ◉ Annunciator Panel Answer: Panel that provides emergency responders with information about the location and type of alarm ◉ Maximum allowed level for all audible alarm signals Answer: 110 dBa ◉ Radiant Energy Detector Answer: A type of detector that looks for specific portions of the visible and invisible light spectrum produced by flames, sparks, or embers ◉ NFPA 72 Deals with Answer: National Fire Alarm Code ◉ Beam Detector Answer: Projects a narrow beam of light across a large open area from a sending unit to a receiving unit. When the beam is interrupted by smoke it activates the alarm ◉ Photoelectric Smoke Detector Answer: Uses a small light source, either an incandescent bulb or a light emitting diode to detect smoke. It is done by shining a light through the chamber and smoke particles reflect it.

◉ Ionization Smoke Detector Answer: A device containing a small amount of radioactive material that ionizes the air between two charged electrodes to sense the presence of smoke particles ◉ General Alarms Sound through Answer: an entire structure ◉ Line Detector Answer: wire or tubing that can be strung along the ceiling of large open areas to detect an increase in the heat ◉ Supervisory Signal Answer: Signal given by a fixed fire protection system indicating readiness status of the system and devices ◉ Trouble Signal Answer: A signal initiated by the fire alarm system or device indicative of a fault in a monitored circuit or component ◉ FACP Means Answer: Fire Alarm Control Panel ◉ Amount of time a battery backup system must run in normal mode Answer: 24 Hours ◉ The mounting distance above the floor for a manual pull station Answer: 42'' ~54"

◉ Exit Discharge Answer: The portion of the means of egress system between the termination of the exit and the public way ◉ Travel Distance Answer: The total distance a person travels within the exit access to reach an enclosed exit stairway or exterior door, or horizontal exit ◉ Wet Barrel Hydrant Answer: Popular in warm climates. The battle is full with water at all times ◉ Dry Barrel hydrant Answer: water is pumped or drained when not in use. It protects it in freezing climates. ◉ 200 PSI for 2 Hours Answer: Minimum pressure required during a hydrostatic test to check for leaks. ◉ Hip Roof Answer: It is a pitched roof that has no gables and all facets of the roof slope down from the peak. ◉ Define a High Rise Answer: Exceeds 80~100 feet, is build of a combination of concrete and protected steel ◉ Seismic design includes ____ bracing Answer: lateral

◉ Elevator Operation Phase 1 Answer: The elevator is recalled to a certain floor and the door remains open ◉ Elevator Operation Phase 2 Answer: Allows Emergency use of the elevator with certain safe guards and special functions ◉ Heat Transfer Answer: Process where by heat moves from one body or substance to another by radiation, conduction, ... ◉ MSDS Answer: Material Safety Data Sheet ◉ Class A Answer: Ordinary Combustibles, wood, paper, wool, things that when burned leave ash ◉ Class B Answer: Flammable Liquids ◉ Class C Answer: Fires involving energized electrical equipment ◉ Class D Answer: Combustible Metals ◉ Class K Answer: Combustible cooking products such as vegetable or animal oils and fats

◉ Class 1 Standpipe Answer: They are equipped with a 2 1/2 inch hose and are designed to be used by fire personnel only ◉ Class 2 Standpipe Answer: They are equipped with 1 1/2 inch outlets and are small diameter for use by the building occupants ◉ Class 3 Standpipe Answer: This has both 1 1/2 inch and 2 1/ inch connections ◉ Wet Standpipe Answer: Continuously pressurized with water from a public supply ◉ Automatic Dry Standpipe Answer: Filled with pressurized air and upon opening of a hose a valve drops the air pressure that permits the dry pipe to activate allowing water into the system ◉ 175 PSI Answer: Maximum listed pressure for most standpipe and sprinkler systems ◉ FDC Answer: Fire Department Connection ◉ Maximum distance a hydrant should be from a FDC Answer: 100'

◉ Heat of Hydration Answer: During the hardening of concrete, heat is given off by the chemical process in hydration ◉ Concrete is reinforced to Answer: Resist the tensile forces upon it ◉ Monitor Roof Answer: Common in factory buildings. They have a raised central section that extends several feet above the surrounding roof surface ◉ Post-tensioned Reinforcing Answer: The Reinforcing steel is tensioned after the concrete is hardened ◉ Pre-tensioned reinforcing Answer: Steel strands are stretched between anchors producing a tensile force in the steel, then concrete is placed around and allowed to harden. ◉ Rafter Answer: Inclined beam that supports a roof, runs parallel to the slope ◉ Smoldering Answer: Burning with a little smoke and no flame ◉ Pre-ignition Answer: Energy transfer from a gas to a fuel

◉ Pitot tube Answer: Measures the velocity pressure ◉ Jockey Pump Answer: Term used to describe a small pump used to maintain the pressure level in water based fire protection due to small fluctuations in the system ◉ Driver Answer: Term used to describe an electric engine or diesel motor that provides power to the fire pump ◉ What is cold flow? Answer: The creeping or sliding of the fusible link of a sprinkler head caused by repeated heating ◉ How often you should do a halon test? Answer: Semi-Annually ◉ At what occupant load is a fire alarm system required for Assembly Occupancies? Answer: 300 or Greater ◉ What is the occupant load factor for figuring a library reading room? Answer: 50 net feet squared ◉ The horizontal measurement on stairs is called the ____ Answer: Run ◉ _____ % of fire doors actually work Answer: 50

◉ In structural steel, a symbol such as W12X16 means Answer: W = type of beam, 12 = nminal depth, 16 = weight per linear foot ◉ What is the maximum height of an ordinary block bearing wall Answer: 6 Stories ◉ What happens to marble when subjected to heat? Answer: Turns to chalk ◉ What size basements require sprinkler protection? Answer: 2500 Square Feet or More ◉ What is the color Coding and GPM on hydrants? Answer: Red = less than 500 GPM, Orange - 500 - 999 GPM, Green 1000-1499 GPM, Light Blue = 1500 GPM PLUS ◉ What is passive fire defense Answer: Fire Walls and Doors ◉ What temperature flash point is a flammable rating? Answer: Less Than 100 Degrees F, OVER 100 it is combustible ◉ What is needed to stabilize a pre-cast tilt slab wall? Answer: Roof

◉ What is the maximum of the property a tent may cover? Answer: 75 Percent ◉ How many days does concrete take to set to it's designed strength? Answer: 28 Days ◉ Steel is how many times stronger than concrete? Answer: 15 Times ◉ Fire Drills should be conducted in educational facilities at what interval? Answer: Every month well school is in session? ◉ What is the name of the test used to rate flame spread? Answer: Steiner Tunnel Test ◉ What type of doors do freight Elevators have? Answer: Counter Balanced ◉ What is the minimum fire resistance rating for enclosures connecting 4 or more stories? Answer: 2 Hour ◉ What are the dimension lines? Answer: They extend for length of distance being measured

◉ What is vellum? Answer: Transparent paper original drawings are on ◉ What type of mortar is for underground masonry? Answer: Type M ◉ How many square feet may a sprinkler cover in a low hazard? Answer: 225 Feet ◉ What are the three classes of stand pipe systems? Answer: Class 1

  • Fire Personnel Only Class 2 - Occupants Only Class 3 - Both Fire/Occupants ◉ Orthographic projections are Answer: Three Dimensional ◉ In a lodging or room house where a sleeping room is above the level of exit discharge, the primary means of escape shall be? Answer: -- Enclosed Stairs -- horizontal exit -- Exterior Stair -- or a fire escape