



Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
ASNT Level III Basic Exam Questions with Solution 2026
Typology: Exams
1 / 6
This page cannot be seen from the preview
Don't miss anything!




SNT-TC-1A is not intended to be used as a strict specification. - correct answer Which of the following statements is true concerning the usage of SNT-TC-1A? Written and stated in general terms - correct answer The SNT-TC-1A Interpretation Panel will respond to inquiries about SNT-TC-1A. The inquiry must be: May engage an outside service but is, nevertheless, responsible for the certification of the company's NDT personnel - correct answer With regard to the training of NDT personnel, the employer: To establish their own written practice that must be used as a strict specification. - correct answer SNT-TC-1A is intended as a guideline for employers: The employer should review the detailed recommendations and modify them as necessary to meet its particular needs. - correct answer The following is a statement in SNT-TC-1A "It is recognized that these guidelines may not be appropriate for certain employers; circumstances and / or applications." What should be done if the guidelines are not appropriate? The individual's employer. - correct answer Who should be responsible to assess whether or not an individual should be qualified and certified who does not perform NDT, but monitors and evaluates NDT? Holographic testing - correct answer To which of the following NDT methods is SNT- TC-1A currently not applicable With flexibility and reason - correct answer ASNT intended that the recommendations of SNT-TC-1A be applied The employer. - correct answer Of the following, which is most appropriate to determine the needs to qualify and certify personnel whose only NDT function is to operate digital thickness equipment. Written testimony of qualification. - correct answer Certification is It has been specified by the customer. - correct answer Use of SNT-TC-1A is mandatory when:
Level I, II, III. - correct answer The basic levels of qualification recommended by SNT- TC-1A are: Weather any NDT personnel should be qualified and certified depends solely upon the needs of the employer and the requirements of the employer's customers or clientele. - correct answer Should personnel that operate ultrasonic digital thickness measurement equipment to qualified and certified The Trainee may not conduct nondestructive test independently and may not report test results - correct answer According to the recommendations of SNT-TC-1A which of the following is true concerning a Trainee's activities? Must train and examine the Level I and II personnel in his or her organization. - correct answer According to SNT-TC-1A, which of the following is not true for a Level III? Specific calibrations, Specific nondestructive test, specific evaluations, and write reports of test results. - correct answer According to written instructions, an NDT Level I may be qualified to perform: Yes, the intent in SNT-TC-1A is that the Level I may perform the above functions provided that they are in accordance with written instruction of a Level III or designee. - correct answer May a Level I independently perform, evaluate and sign for results of nondestructive test with supervision and guidance from a Level II or III? The qualifications for Level III equal and exceed those of Level II. - correct answer Which of the following statements is true concerning the definitions of Trainee, Level I, II and III in SNT-TC-1A? Establish techniques - correct answer Which of the following is not within the scope of activities of a Level II individual, as recommended in SNT-TC-1A? My conduct on the job training and guidance of Level I personnel. - correct answer A recommended in SNT-TC-1A, a Level II: The Level III shall be capable of evaluating test results in terms of codes standards and specifications. - correct answer According SNT-TC-1A which of the following is true for a Level III? The employer. - correct answer In Accordance with SNT-TC-1A, who is responsible for establishing a written practice for the control and administration of NDT personnel training, examination and certification? Should be described in the employer's written practice only if they are different form SNT-TC-1A recommendations. - correct answer The responsibility of each level of certification for determining the acceptability of materials or components:
Technical principles of the method. - correct answer The recommended training course outline includes All questions to be used on examinations for Level I and Level II. - correct answer In accordance with SNT-TC-1A, the NDT Level III shall be responsible for: A selected representative of the NDT Level III. - correct answer Which of the following may conduct a grade examinations for Level I and Level II personnel? An NDT level III - correct answer Of the following personnel, who can administer the near-distance, vision acuity examination using the reading card with Jaeger Letters? Related to each employer's specific needs - correct answer As recommended in SNT- TC-1A, physical examination requirements are intended to be: Basic test principles of the method - correct answer The General Examination is intended to cover: The general, basic and method examinations. - correct answer Questions and answers available from ASNT are intended for use in compiling The General and Specific - correct answer Which of the following parts of Level I and Level II examinations should be written? Trainees, Level I and Level II. - correct answer The practical examination is recommended to include operational familiarity with test equipment and analysis of test results for: Level III personnel should be required to memorize everything except codes specifications and procedures. - correct answer Which of the following statements is true with regard to the administration of written examinations? During all examinations - correct answer For the written examinations, tables, graphs and charts may be used Three - correct answer For Level I and Level II practical Examinations, one or more test specimens are recommended and the examinee should preform test and evaluations using minimum number of different checkpoints recommended is: May delete the specific examination. - correct answer In certification of Level III personnel according to the recommendations of SNT-TC-1A, the employer
For Level I and II examinations, the recommended minimum composite score is - correct answer For Level I and II examinations, the recommended minimum composite score is Level II type questions based on other applicable NDT methods. - correct answer For Level III Basic examinations, it is recommended that Level III questions also be included. These questions should be: Responsibility of certification must be retained by the employer utilizing outside services