FIRE PROTECTION SYSTEMS FINAL
EXAM
Photoelectric-Detector---ans-✔✔The-type-of-smoke-detector-that-detects-the-visible-
products-of-combustion.
Infrared-Detector---ans-✔✔A-detector-that-responds-to-the-optical-radiant-energy-of-a-fire-
in-one-of-two-non-visible-light-spectrums
Rate-of-Rise-Detector---ans-✔✔This-type-of-detector-is-designed-for-use-in-areas-that-
have-regular-temperature-changes-and-results-in-fewer-false-activations
Fire-Gas-Detector---ans-✔✔Carbon-monoxide-and-carbon-dioxide-are-typical-products-of-
combustion-sensed-by-this-type-of-detector
Rate-of-Rise-Detector---ans-✔✔A-type-of-heat-detector-that-responds-to-a-rapid-increase-
in-temperature-rather-than-a-specific-temperature
Pull-Station---ans-✔✔A-manual-alarm-initiating-devices
Photoelectric-Detector---ans-✔✔Type-of-smoke-detector-that-reacts-quicker-to-
smouldering-fires
Spot-Detector---ans-✔✔A-detector-that-monitors-the-exact-area-of-location-were-process,-
rather-than-a-large-area
Ionization-Detector---ans-✔✔A-small-amount-of-radioactive-material,-Americium,-is-used-
in-this-type-of-smoke-detector
Fixed-Temperature-Detector---ans-✔✔Detector-that-responds-at-a-given-temperature-
regardless-of-how-rapidly-that-temperature-is-reached
Ionization-Detector---ans-✔✔The-invisible-products-of-combustion-are-sensed-by-this-
type-of-smoke-detector
Automatic-Initiating-Devices---ans-✔✔Heat,-smoke,-flame-and-fire-gas-detectors
Ionization-Detectors---ans-✔✔Flaming-fires-cause-this-smoke-detector-to-respond-faster-
to-the-products-of-combustion
pf3
pf4
pf5

Partial preview of the text

Download FIRE PROTECTION SYSTEMS FINAL EXA1. and more Study notes Biology in PDF only on Docsity!

FIRE PROTECTION SYSTEMS FINAL

EXAM

Photoelectric-Detector---ans-✔✔The-type-of-smoke-detector-that-detects-the-visible- products-of-combustion. Infrared-Detector---ans-✔✔A-detector-that-responds-to-the-optical-radiant-energy-of-a-fire- in-one-of-two-non-visible-light-spectrums Rate-of-Rise-Detector---ans-✔✔This-type-of-detector-is-designed-for-use-in-areas-that- have-regular-temperature-changes-and-results-in-fewer-false-activations Fire-Gas-Detector---ans-✔✔Carbon-monoxide-and-carbon-dioxide-are-typical-products-of- combustion-sensed-by-this-type-of-detector Rate-of-Rise-Detector---ans-✔✔A-type-of-heat-detector-that-responds-to-a-rapid-increase- in-temperature-rather-than-a-specific-temperature Pull-Station---ans-✔✔A-manual-alarm-initiating-devices Photoelectric-Detector---ans-✔✔Type-of-smoke-detector-that-reacts-quicker-to- smouldering-fires Spot-Detector---ans-✔✔A-detector-that-monitors-the-exact-area-of-location-were-process,- rather-than-a-large-area Ionization-Detector---ans-✔✔A-small-amount-of-radioactive-material,-Americium,-is-used- in-this-type-of-smoke-detector Fixed-Temperature-Detector---ans-✔✔Detector-that-responds-at-a-given-temperature- regardless-of-how-rapidly-that-temperature-is-reached Ionization-Detector---ans-✔✔The-invisible-products-of-combustion-are-sensed-by-this- type-of-smoke-detector Automatic-Initiating-Devices---ans-✔✔Heat,-smoke,-flame-and-fire-gas-detectors Ionization-Detectors---ans-✔✔Flaming-fires-cause-this-smoke-detector-to-respond-faster- to-the-products-of-combustion

Spot-Detector---ans-✔✔Heat-causes-electrical-current-to-flow-between-two-wires-of- dissimilar-metals.-More-heat-results-in-more-current Remote-station-alarm-system---ans-✔✔Alarm-system-connected-to-the-Dispatch-Center- through-a-leased-telephone-line-or-a-radio-signal-over-a-dedicated-fire-department- frequency Proprietary-alarm-system---ans-✔✔Alarm-system-used-to-protect-large-buildings-or- complexes-in-a-single-location-with-the-alarm-signal-received-at-an-on-site-staffed-location Protected-premises-alarm-system---ans-✔✔Alarm-system-that-transmits-both-a-visible- and-an-audible-alarm-on-the-immediate-premises-only,-known-as-a-local-alarm-system Central-Station-alarm-system---ans-✔✔The-receiving-point-of-the-alarm-is-an-outside,- contracted-service Auxiliary-alarm-system---ans-✔✔Alarm-is-transmitted-directly-to-the-fire-department- through-a-municipal-fire-box-system Emergency-voice/alarm-system---ans-✔✔Used-to-supplement-other-systems-and-can-be- one-way-or-two-way-configuration NFPA- 70 - --ans-✔✔The-national-fire-alarm-and-signaling-code Trouble-signal---ans-✔✔A-FACU-will-identify-what-for-a-power-failure-or-system- malfunction? Supervisory-signal---ans-✔✔A-FACU-will-identify-what-for-an-off-normal-condition Fire-detection-systems---ans-✔✔Systems-used-to-determine-if-Fire-or-the-products-of- combustion-are-present-and-then-signaling-that-these-elements-are-present Fire-suppression-systems---ans-✔✔Systems-designed-and-installed-at-directly-upon-the- hazard-to-mitigate-or-eliminate-the-hazard Static-pressure---ans-✔✔Pressure-that-is-the-stored-potential-energy-available-to-force- water-through-pipe,-fittings,-fire-hose,-and-adapters.-Pressure-when-no-water-is-flowing. Normal-operating-pressure---ans-✔✔Pressure-that-is-found-in-a-water-distribution-system- during-typical-conception-demands Residual-pressure---ans-✔✔Part-of-the-total-available-pressure-not-used-to-overcome- friction-loss-or-grabbing-while-forcing-water-through-pipe,-fittings,-and-adapters

Heat-sensing-device---ans-✔✔The-part-of-a-sprinkler-head-that-determines-the-activation- temperature Deflector---ans-✔✔The-part-of-a-sprinkler-head-that-forms-the-water-discharge-pattern Deflector---ans-✔✔The-part-of-a-sprinkler-head-that-determines-its-mounting-position Discharge-orifice---ans-✔✔The-part-in-an-automatic-sprinkler-head-that-determines-the- amount-of-water-that-will-flow-from-the-head-at-a-given-pressure Ambient-ceiling-temperature---ans-✔✔The-basis-for-selecting-the-operating-temperature- of-a-sprinkler-head Heat-sensing-device---ans-✔✔Color-coding-of-this-will-identify-the-operating-temperature- classification-of-frangible-glass-bulb-sprinkler-heads NFPA- 25 - --ans-✔✔The-Standard-for-the-Inspection-Testing-and-Maintenance-of-Water- Based-Fire-Protection-Systems NFPA- 13 - --ans-✔✔Standard-for-the-Installation-of-Sprinkler-Systems Check-valve---ans-✔✔A-type-of-valve-which-prevents-recirculation-or-backflow-of-water- from-a-sprinkler-system-into-the-Municipal-Water-Supply-system Butterfly-valve---ans-✔✔A-type-of-valve-that-has-a-disk-that-rotates- 90 - degrees-inside-the- water-way-to-control-the-flow-of-water Indicating-valve---ans-✔✔The-only-type-of-valves-that-may-be-used-as-the-main-control- valve-in-sprinkler-systems Closed-water-control-valves---ans-✔✔Most-common-reason-for-sprinkler-system-failure 15 - feet---ans-✔✔As-identified-in-NFPA-standards,-the-maximum-sprinkler-head-and- branch-line-spacing-in-a-sprinkler-system-designed-using-the-pipe-schedule-method-is- what? 200 - feet---ans-✔✔According-to-NFPA-standards-when-using-the-pipe-schedule-design- method-the-maximum-area-of-coverage-for-each-sprinkler-head-is-what? Preaction---ans-✔✔The-sprinkler-system-that-provides-an-early-warning-of-complete- system-activation-to-permit-manual-Fire-Control-efforts-before-water-discharges-from- sprinkler-heads Deluge---ans-✔✔Manual-system-activation-is-an-option-for-what-type-of-sprinkler- systems?

Wet-pipe---ans-✔✔Sprinkler-system-that-is-the-most-reliable,-effective,-and-requires-the- least-amount-of-maintenance Deluge---ans-✔✔Open-heads-with-no-fusible-element-are-used-in-this-sprinkler-systems Preaction---ans-✔✔Sprinkler-system-that-is-typically-used-to-protect-buildings-with-high- value-contents-or-stock,-where-unnecessary-water-damage-may-be-an-issue Dry-pipe---ans-✔✔The-sprinkler-systems-that-are-often-known-for-their-differential- principle-of-operation Deluge---ans-✔✔This-sprinkler-system-is-used-in-high-Hazard-areas-requiring-large- amounts-of-water-or-fire-control-or-extinguishment-due-to-large-or-fast-moving-fire- potential Deluge---ans-✔✔Triggering-a-heat-activating-device-in-this-system-will-cause-water-to- enter-the-piping-and-discharge-through-all-sprinkler-heads Wet-pipe---ans-✔✔This-sprinkler-system-contains-water-under-pressure-in-the-piping-at- all-times Dry-pipe---ans-✔✔Quick-opening-devices-speed-up-the-activation-of-what-type-of- sprinkler-system Preaction---ans-✔✔Triggering-of-a-heat-activating-device-will-cause-water-to-flow-into-the- piping-but-not-discharge-through-the-sprinkler-head-in-what-type-of-sprinkler-system? Wet-pipe---ans-✔✔When-heat-causes-the-sprinkler-head-to-activate-water-discharges- from-a-sprinkler-head-immediately-in-what-type-of-sprinkler-system? Dry-pipe---ans-✔✔Areas-subject-to-freezing-are-most-often-protected-by-what-type-of- sprinkler-system? Wet-pipe---ans-✔✔A-retard-chamber-is-a-common-component-of-what-sprinkler-system- that-limits-false-alarms-by-compensating-for-pressure-fluctuations-in-the-water-supply? 18 - --ans-✔✔To-be-effective,-sprinkler-heads-require-a-clearance-of-at-least-how-many- inches-measured-from-the-deflector-to-any-stock-placed-below? Sprinkler-contractor---ans-✔✔The-fundamental-responsibility-for-doing-the-necessary- work-to-store-in-automatic-sprinkler-system-to-service-lies-with-who Fire-Inspector---ans-✔✔It-is-the-responsibility-of-who-for-having-the-required-maintenance- and-testing-of-automatic-sprinkler-systems-performed?

True---ans-✔✔True-or-False:-an-accelerator-is-a-type-of-quick-opening-device-that- unbalanced-is-the-pressure-differential-in-a-dry-pipe-valve False---ans-✔✔True-or-False:-as-it-applies-to-a-special-type-of-sprinkler-head-ESFR- stands-for-early-signal-fire-response True---ans-✔✔True-or-False:-the-inspectors-test-component-of-an-automatic-sprinkler- system-is-designed-to-stimulate-the-water-flow-through-a-single-sprinkler-head False---ans-✔✔True-or-False:-the-fire-department-connection-not-only-serves-as-the-point- where-the-fire-department-can-supplement-a-water-supply-to-the-sprinkler-system-but-also- serves-as-a-source-of-water-for-fire-operations-when-the-sprinkler-system-has-not- activated .90---ans-✔✔The-coefficient-of-discharge-for-a-hydrant-discharge-that-is-smooth/rounded .70---ans-✔✔The-coefficient-discharge-of-a-hydrant-discharge-that-is-square-and- protruding .80---ans-✔✔The-coefficient-of-discharge-for-a-hydrant-discharge-that-is-square-and-non- protruding