This study guide provides a series of questions and answers designed to help lineman apprentice program participants prepare for their tests. It covers essential skills and techniques necessary to determine normal voltage of exposed parts, safety-related work practices, and the proper use of protective equipment. The guide includes topics such as regular supervision, training methods, working near energized lines, and grounding procedures. It also addresses rescue techniques, rope handling, and conductor fastening, offering a comprehensive overview of key concepts for qualified employees.
Typology: Exams
1 / 6
This page cannot be seen from the preview
Don't miss anything!




Qualified |\employees |\shall |\be |, |\trained |\and |\contempt |\in |\the |\skills |
and |\techniques |\necessary |\to |\determine |\normal |\voltage |\of |
exposed |\parts? |\True |\or |\false |- |\CORRECT |\ANSWERS |\✔✔True Regular |\supervision |\conducted |\on |\a |............. |\Basis |\will |\determine |
that |\each |\employee |\is |\complying |\with |\the |\safety |\related |\work |
practices |- |\CORRECT |\ANSWERS |\✔✔Annual Training |\may |\be |\classroom |\or |\on |\the |\job? |\True |\or |\False |- |
CORRECT |\ANSWERS |\✔✔True At |\least |\two |\employees |\Shelby |\present |\while |\the |\following |\work |
is |\performed? |
A. |\Installation |\repair |\or |\removal |\of |\lines |\energize |\at |\less |\than |\ 600 |\V B. |\Installation |\repair |\of |\lines |\energized |\at |\more |\than |\ 600 |\V C. |\All |\of |\the |\above |- |\CORRECT |\ANSWERS |\✔✔B. |\Installation |\repair |
of |\lines |\energize |\that |\more |\than |\ 600 |\V When |\work |\is |\to |\be |\done |\near |\energize |\lines |\all |\energize, |
grounded, |\conductors, |\or |\guy |\wires |\within |\reach |\Shall |\be............ |- |\CORRECT |\ANSWERS |\✔✔Covered
Flexible, |\protective |\equipment |\shall |\be |\inspected............ |- |
CORRECT |\ANSWERS |\✔✔Each |\use An |\air |\test |\shall |\be |\Preformed |\lineman, |\rubber |\gloves, |\how |\often? |- |\CORRECT |\ANSWERS |\✔✔Before |\each |\use |\or |\damage |\expected What |\is |\the |\maximum |\use |\voltage |\for |\class |\three |\rubber |\gloves? |- |\CORRECT |\ANSWERS |\✔✔26, What |\is |\the |\maximum |\use |\voltage |\for |\class |\for |\rubber |\gloves? |- |
CORRECT |\ANSWERS |\✔✔36, Voltage |\shall |\be |\considered |\to |\be |\phase-to-phase |\voltage |\unless |
all |\conductors |\are |\covered, |\except |\the |\one |\being |\worked? |\True |\or |\False |- |\CORRECT |\ANSWERS |\✔✔True Workers |\handling |\the |\butt |\of |\a |\pole |\shall |\wear, |\rubber |\gloves? |\T |
or |\F |- |\CORRECT |\ANSWERS |\✔✔True What |\is |\the |\maximum |\use |\voltage |\for |\class |\two |\rubber |\gloves? |- |
CORRECT |\ANSWERS |\✔✔17, Some |\minimum |\approach |\distances |\are |\considered |\rubber |\gloves |\ground |\to |\ground? |\T |\or |\F |- |\CORRECT |\ANSWERS |\✔✔True Signal |\flags, |\Shall |\be |\red |\and |\at |\least? |- |\CORRECT |\ANSWERS |
✔✔ 24 |\inches
........ |\grounds |\connection |\is |\designed |\to |\keep |\the |\conductor |
grounded |\during |\stringing |\operations |- |\CORRECT |\ANSWERS |
✔✔Running Grounding |\jumpers |\shall |\Consist |\of |\1/0 |\Solid |\copper |\or |\larger? |\T |
or |\F |- |\CORRECT |\ANSWERS |\✔✔False When |\calling |\to |\the |\man |\on |\the |\pole, |\if |\he |\does |\not |\answer |\or |
appear |\stunned |\or |\dazed, |\you |\should |\be |\prepared |\to |- |\CORRECT |
ANSWERS |\✔✔Aid |\The |\lineman When |\Preparing |\to |\rescue |\the |\victim |\the |\best |\position |\is |\Slightly |.............. |\The |\victim |- |\CORRECT |\ANSWERS |\✔✔above What |\size |\hand |\line |\is |\required |\for |\rescue |- |\CORRECT |\ANSWERS |
✔✔1/2" Fiber |\ropes |\may |\have |\two |\kinks |\per |\reel? |\T |\or |\F |- |\CORRECT |
ANSWERS |\✔✔False Knots |\in |\a |\rope |\can |\reduce |\Rope |\strength |\by...............% |\or |\more |- |\CORRECT |\ANSWERS |\✔✔50% ................ |\Ropes |\are |\used |\for |\raising |\or |\lowering |\heavy |\pieces |\of |
equipment |- |\CORRECT |\ANSWERS |\✔✔Bull |\Rope
This |\line |\is |\used |\for |\pulling |\in |\several |\span |\lengths |\or |\wire |- |
CORRECT |\ANSWERS |\✔✔Running |\line This |\line |\is |\used |\for |\raising |\and |\lowering |\light |\materials |\and |\tools |- |\CORRECT |\ANSWERS |\✔✔Handline Clean, |\dry |\polypropylene |\Rope |\is |\an |\insulator? |\T |\or |\F |- |\CORRECT |
ANSWERS |\✔✔True What |\not |\is |\used |\when |\tying |\a |\rope |\to |\a |\pole |- |\CORRECT |
ANSWERS |\✔✔Timber |\hitch This |\note |\is |\used |\to |\tie |\to |\ropes |\of |\the |\same |\diameter |\together |- |
CORRECT |\ANSWERS |\✔✔Square |\knot Not |\used |\to |\tie |\ropes |\of |\different |\diameter |\together |- |\CORRECT |
ANSWERS |\✔✔Single |\sheet |\bend This |\not |\is |\used |\to |\place |\a |\loop |\in |\the |\middle |\of |\a |\Rope |- |
CORRECT |\ANSWERS |\✔✔Bowline |\On |\a |\bite Conductors |\are |\fashioned |\to |\insulators |\by |\the |\use |\of |
either.............. |\or |................. |- |\CORRECT |\ANSWERS |\✔✔Ties |\or |
clamps