Hitachi Printer - Model UX 5ta parte, Study Guides, Projects, Research of Industrial Engineering

Hitachi Printer - Model UX Basic Operation Manual 5ta parte

Typology: Study Guides, Projects, Research

2019/2020

Uploaded on 01/10/2020

jonathan-rodriguez-18
jonathan-rodriguez-18 🇺🇸

6 documents

1 / 10

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
8-11 Replenishing the makeup
1
3
2
When the makeup ID is read, the lock on the makeup side is released.
3
Lever handle Lift the lever handle and remove the empty
cartridge bottle.
After removing the cartridge bottle from the IJP, quickly place the cap toward
the top. Also do not expose the cartridge bottle to impacts after being removed.
Doing so could cause ink to splatter.
Do not put waste solution in used cartridge bottles.
Waste solution could spill. You should note that used cartridge bottles are not
hermetically sealed even when the over cap is mounted.
If used cartridge bottles are filled with ink or makeup and reused, ink or
makeup could spill.
CAUTION
Tilt the lever handle toward yourself, lift and remove the
cartridge bottle.
41 2 3
If the lever handle could not be lifted up, do not pull it with excessive force.
In such a case, push the lever handle all the way in.
CAUTION
Push
Lever handle
Downloaded from www.Manualslib.com manuals search engine
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download Hitachi Printer - Model UX 5ta parte and more Study Guides, Projects, Research Industrial Engineering in PDF only on Docsity!

8-11 ●Replenishing the makeup

3 When the makeup ID is read, the lock on the makeup side is released.

Lever handle Lift the lever handle and remove the empty cartridge bottle.

● After removing the cartridge bottle from the IJP, quickly place the cap toward the top. Also do not expose the cartridge bottle to impacts after being removed. Doing so could cause ink to splatter. ● Do not put waste solution in used cartridge bottles. Waste solution could spill. You should note that used cartridge bottles are not hermetically sealed even when the over cap is mounted. ● If used cartridge bottles are filled with ink or makeup and reused, ink or makeup could spill.

CAUTION

Tilt the lever handle toward yourself, lift and remove the

cartridge bottle.

● If the lever handle could not be lifted up, do not pull it with excessive force. In such a case, push the lever handle all the way in.

CAUTION

Push

Lever handle

●Replenishing the makeup 8-

Set a new cartridge bottle in the specified position.

Set the boss provided on the cartridge bottle to the boss guide of the makeup supply port.

Makeup side

Boss

● If a foreign object such as a screw is found or gets in the makeup supply port, remove it.

CAUTION

Set a new cartridge bottle.

Makeup supply port

Boss guide

●Display when warning or fault was generated 9-

052 Target Sensor Fault

The print target detection signal was ON longer than the timeout setting of Target Sensor Timer. Cause 1. The print target detection signal ON time is too long.

  1. The Target Sensor Timer setting is incorrect. Solution 1. If the target is stopped in front of the sensor, move the target.
  2. Change the Target Sensor Timer setting.

Reset Close

9. WHEN WARNING OR FAULT

WAS GENERATED

●When an operation mistake is made and processing judgment is prompted, a confirmation message is displayed. ●When a “Fault state” which hinders printing was generated while the liquid crystal screen backlighting was off or when a “Warning state” which does not hinder printing but requires maintenance was generated, a fault message or warning message is displayed in a window.

(1) When a fault was generated (a) Previous HM I

9.1 Display when warning or fault was generated

●When a warning or fault was generated, a warning or fault lamp lights.

Operational status display lamp

Message No.

The name of the fault message is displayed.

The description, cause, and solution are displayed.

Target Sensor Timer out The print target detector signal was ON longer than the timeout setting of Target Sensor Timer. Cause 1. The print target detector signal ON time is long.

  1. The Target Sensor Timer setting is incorrect. Solution 1. If the target is stopped in front of the sensor, move the target.
  2. Change the Target Sensor Timer setting.

●When Clear is pressed after removing the cause, the fault state is cleared and the message is also closed. ●When Close is pressed, the fault window is closed, but the fault state is not cleared. When Fault in state area, the fault message is displayed again. ●However, when the fault state is already cleared, it is cleared by Close.

(b) New HM I

Message No.

The description, cause, and solution are displayed.

The name of the fault message is displayed.

9-2 ●Display when warning or fault was generated

081 Ink Low Warning The ink level in the ink reservoir is low. Cause 1. The ink reservoir is almost empty.

  1. The Low Level sensor in the ink reservoir is faulty. Solution 1. Replace the Ink Cartridge within 60 minutes.
  2. Check the Low Level sensor.

Close

Ink Low Warning The ink level in the ink reservoir is low. Cause 1. The ink reservoir is almost empty.

  1. The Low Level sensor in the ink reservoir is faulty. Solution 1. Replace the Ink Cartridge within 60 minutes.
  2. Check the Low Level sensor.

●When Close is pressed, the warning window is closed, but the warning state is not cleared. The warning name is displayed in the warning display area (see the figure above). ●If the warning state is cleared, the warning display is automatically closed.

(2) When warning was generated (a) Previous HM I

Message No.

The name of the warning message is displayed.

The description, cause, and solution are displayed.

(b) New HM I

Message No.

The name of the warning message is displayed.

The description, cause, and solution are displayed.

9-4 ●Display when warning or fault was generated

Operating Time Ink Presure Standard Value

Print Count

Makeup Ink

TEST START PRINTING STARTUP

Main Ink Tank Too Full The ink level in the main ink tank is too high. Cause1. The valve (MV2) or valve (MV7) is faulty.

  1. The High Level sensor in the main ink tank is faulty. Solution1. Drain proper amount of ink in the main ink tank.
  2. Check the High Level sensor.
  3. Contact your local distributor.

Print description [Stop]

Ink operating time(hours) Cumulative op. time(hours) Print count(prints) Ink pressure(MPastandard value: )

Message name[] Current user ID : user

Makeup Ink

  1. Drain proper amount of ink in the main ink tank.

● If the message prompts the guidance, HELP will be shown on upper right corner. ● When HELP is pressed, the guidance for the fault/warning will appear.

● When Back is pressed, the guidance will be closed and the message will be shown again.

● The messages listed below have guidance.

No. Type Message 1

Fault

Main Ink Tank Too Full 2 Ink Drop Charge Too Low 3 Deflection Voltage Leakage 4 No Ink Drop Charge 5 Ink Drop Charge Too High

(b)New HMI

Displays the guidance.

●When checking the warning and fault generation status 9-

Fault/warning log

Fault/warning log

[Stop ]

No 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

Date/time Name of alarm

Makeup Ink

9.2 When checking the warning and fault generation status

(1) Functions ●The warning or fault message generation time and contents can be viewed. ●A maximum of 90 messages can be displayed. ●When 90 messages are exceeded, the messages are closed from the oldest message.

(2) Operation

1 Press View alarm history in the Manage messages screen.

The Fault/warning screen is displayed.

Sorted from generation date.

Message No.

●Remedial action to be taken in the event of a printing failure 9-

No.

Printing failure description (phenomenon)

Probable cause Solution Reference

Disordered characters

There are water, oil, or other deposits on the print target surface.

● Make prints with the print target clear of deposits.

The ink pressure has changed. ● Adjust the ink pressure for the standard value.

Ink and foreign matter are stuck to the charge and deflection electrodes.

● Clean the charge and deflection electrodes.

The flow within the nozzle is restricted. ● Backwash the nozzle. 6.4 (*2)

The ink has deteriorated. ● Replace the ink. 6.3 (2) The excitation V-ref. value is improper. ● Adjust the excitation V-ref.. 6.10 (2)